Covered in this standard are all liquid-immersed distribution, power, and regulating transformers that are designed to operate at temperatures that exceed the normal thermal limits of IEEE C57.12.00 under continuous load, in the designed average ambient, and at rated conditions. Specific requirements and guidance in the design, testing, and application of the transformers covered within the scope of this standard are provided. High-temperature insulation systems or systems that use a combination of high-temperature and conventional insulation are incorporated by these transformers.
- Standard Committee
- PE/TR - Transformers
- Status
- Active Standard
- PAR Approval
- 2018-09-27
- Superseding
- C57.154-2012
- Board Approval
- 2022-06-16
- History
-
- Published:
- 2022-08-18
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
WGC57.154 - Insulation Life - Standard for the design, testing and application of liquid-immersed distribution, power and regulating transformers using high-temperature insulation systems
- IEEE Program Manager
- Patrycja Jarosz
Contact Patrycja Jarosz - Working Group Chair
- Richard Marek
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C57.154-2012
IEEE Standard for the Design, Testing, and Application of Liquid-Immersed Distribution, Power, and Regulating Transformers Using High-Temperature Insulation Systems and Operating at Elevated Temperatures
All liquid-immersed distribution, power, and regulating transformers that are designed to operate at temperatures that exceed the normal thermal limits of IEEE C57.12.00TM under continuous load, in the designed average ambient, and at rated conditions are covered by this standard. Specific requirements and guidance in the design, testing, and application of the transformers covered within the scope of this standard are provided. High-temperature insulation systems or systems that use a combination of high-temperature and conventional insulation are incorporated by these transformers.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards