Active Standard

IEEE C57.136-2023

IEEE Guide for Audible Sound of Liquid-Immersed Power Transformers

Information on sources of no-load and load sound in liquid-immersed power transformers is provided in this guide. Industry standards that deal with transformer sound and factors affecting sound levels of transformers in field operation are also discussed. Guidelines are provided for the selection of suitable methods of reduction of transformer sound at the design stage, during manufacturing, and on site. Procedures that are typically used for determining required sound levels of power transformers on site are described. The intent is to provide users and manufacturers with sufficient background that can help produce power transformers that meet limits on sound level required by local sound ordinances.

Standard Committee
PE/TR - Transformers
Status
Active Standard
PAR Approval
2021-02-10
Board Approval
2023-06-05
History
Published:
2023-07-24

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/TR - Transformers
Working Group
PerfCharac-WGC57.136 - Performance Characteristics - Sound Level Abatement Working Group
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Stephen Antosz

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


C57.136-2000
IEEE Guide for Sound Level Abatement and Determination for Liquid-Immersed Power Transformers and Shunt Reactors Rated Over 500 kVA

Reaffirmed September 22, 2005. Guidelines are provided for the selection of suitable sound reduction methods in oil-immersed power transformers and shunt reactors over 500 kVA.Sound-producing sources within transformers and reactors are discussed.Sound abatement procedures are described for achieving various levels of sound reduction in transformer and shunt reactor installations.

Learn More About C57.136-2000

Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.