Superseded Standard

IEEE C57.12.51-2008

IEEE Standard for Ventilated Dry- Type Power Transformers, 501 kVA and Larger, Three-Phase, with High- Voltage 601 V to 34 500 V; Low- Voltage 208Y/120 V to 4160 V- General Requirements

This standard is intended to set forth characteristics relating to performance, limited electrical and mechanical interchangeability, and safety of the equipment described, and to assist in the proper selection of such equipment. Specific rating combinations are described in the range from 750/1000 to 7500/10 000 kVA inclusive, with high-voltage 601 to 34 500 volts inclusive and low-voltage 208Y/120 to 4160 volts inclusive. Part I of this standard describes certain electrical and mechanical requirements and takes into consideration certain safety features of 60-Hz, two-winding, three-phase, ventilated dry-type transformers with self-cooled ratings 501 kVA and larger, generally used for step-down purposes. Part Il describes other requirements or alternatives which may be specified for some applications and lists forced-air-cooled ratings for certain sizes.

Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Status
Superseded Standard
PAR Approval
2007-12-05
Superseded by
C57.12.51-2019
Board Approval
2008-09-26
History
ANSI Approved:
2009-08-05
Published:
2009-03-09

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Working Group
WGC57.12.51 - Dry Type - Ventilated Dry-type Working Group
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Sanjib Som

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C57.12.51-2019
IEEE Guide for Mechanical Interchangeability of Ventilated Dry-Type Transformers

Characteristics of ventilated dry-type transformers relating to performance, limited electrical and mechanical interchangeability, as well as recommended practice for installation of equipment are set forth in this guide. Specific rating combinations are described up to 7500 kVA high-voltage class from 1.2 kV to 36 kV inclusive, and low voltage class up to 5 kV. This guide also describes certain electrical and mechanical requirements and takes into consideration certain desirable features of 60 Hz, two-winding, three-phase, ventilated dry-type transformers. Clause 9 through Clause 11 describe other requirements or alternatives that may be specified for some applications.

Learn More About C57.12.51-2019

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.