Design tests for relays, relay systems, and control devices used for protection and control of electric power apparatus that relate to the immunity of this equipment to repetitive electrical transients are specified in this standard. Two types of tests are specified: the slow damped oscillatory test, and the electrical fast transient (EFT ) burst test. For devices with communication ports, where the device does not perform protection or control functions, testing of the communication functions is covered by IEEE Std 1613™. Where the device performs protection or control functions and has communication ports, tests for all communication functions are covered by this document. For devices without communication ports, the tests are covered by this document.
- Standard Committee
- PE/PSRCC - Power System Relaying and Control
- Joint Sponsors
-
EMC/SDCom
- Status
- Active Standard
- PAR Approval
- 2020-09-24
- Superseding
- C37.90.1-2012
- Board Approval
- 2024-09-26
- History
-
- Published:
- 2024-12-10
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/PSRCC - Power System Relaying and Control
- Working Group
-
C37.90.1_WG/I40 - WG for PC37.90.1 Standard for Relays, Relay Systems, and Control Devices used for Protection and Control of Electric Power Apparatus-Surge Withstand Capability (SWC) and Electrical Fast Transient (EFT) Requirements and Tests
- IEEE Program Manager
- Malia Zaman
Contact Malia Zaman - Working Group Chair
- Roger Whittaker
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
C37.90.1-2012
IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
Two types of design tests for relays and relay systems that relate to the immunity of this equipment to repetitive electrical transients are specified. Test generator characteristics, test waveforms, selection of equipment terminals on which tests are to be conducted, test procedures, criteria for acceptance and documentation of test results are described. This standard has been harmonized with IEC standards where consensus could be reached.