Active Standard

IEEE C37.20.1-2015

IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear

Metal-enclosed, low-voltage switchgear–which contains either stationary or drawout, manually or electrically operated low-voltage ac or dc power circuit breakers in individual metal compartments, in three-pole, four-pole, two-pole, or single-pole construction–is covered. Rated maximum voltage levels are 254 V, 508 V, 635 V, 730 V, or 1058 Vac; and 300/325 V, 600 V, 800 V, 1000 V, 1200 V, 1500 V, 1600 V, or 3200 Vdc. The preferred continuous current ratings of the main bus in ac designs are 1600 A, 2000 A, 3000 A, 3200 A, 4000 A, 5000 A, 6000 A, 8000 A, or 10 000 A. For dc designs, the preferred ratings are 1600 A, 2000 A, 2500 A, 3000 A, 4000 A, 5000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear may also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.

Standard Committee
PE/SWG - Switchgear
Status
Active Standard
PAR Approval
2014-08-21
Superseding
C37.20.1-2002
Amendment
C37.20.1a-2020
Board Approval
2015-03-26
History
ANSI Approved:
2016-08-25
Published:
2015-07-13

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SWG - Switchgear
Working Group
SA/37.20.1 - C37.20.1 - Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Michael Lafond

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


PC37.20.1
IEEE Draft Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear

Metal-enclosed, low-voltage switchgear which contains either stationary-mounted or drawout-mounted, manually or electrically operated low-voltage ac or dc power circuit breakers or low-voltage ac definite-purpose switching devices in individual metal compartments, in three-pole, four-pole, two-pole, or single-pole construction is covered. Rated maximum voltage levels are 254 V, 508 V, 635 V, 730 V, or 1058 V ac; and 300/325 V, 600 V, 800 V, 1000 V, 1200 V, 1500 V, 1600 V, or 3200 Vdc. The preferred continuous current ratings of the main bus in ac designs are 1600 A, 2000 A, 3000 A, 3200 A, 4000 A, 5000 A, 6000 A, 8000 A, or 10 000 A. For dc designs, the preferred ratings are 1600 A, 2000 A, 2500 A, 3000 A, 4000 A, 5000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear may also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.

Learn More About PC37.20.1

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.