Active PAR

PC37.10.1

Guide for the Selection of Monitoring for Circuit Breakers

This guide provides direction for the selection of monitoring and for diagnostic parameters to be used with high-voltage circuit breakers (i.e., above 1000 V ac). It provides guidance on appropriate parameters to be considered for monitoring applied to various circuit breaker technologies. This guide leads users through an analysis of circuit breaker performance and application expectations. The analysis includes a failure modes and effects analysis (FMEA) of the circuit breaker and associated components, an analysis of the risks associated with failure of the specific application, and a discussion of the items to be considered in a cost-benefit study to justify application of monitoring in its many forms. This guide provides advice on what parameters can be monitored to derive information about the condition of a circuit breaker. Circuits associated with the operation of the circuit breaker, which might include auxiliary contacts, X and Y relays, lockout switches, and so on, are included in this guide. External control circuits are not included in the scope of this guide. This guide is not intended to provide guidance on the monitoring of protection and control circuits, although they can have a significant effect on the overall circuit breaker functions.

Standard Committee
PE/SWG - Switchgear
Status
Active PAR
PAR Approval
2024-09-26
Superseding
C37.10.1-2018

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SWG - Switchgear
Working Group
HVCB/C37.10.1 - C37.10.1 - Guide for the Selection of Monitoring for Circuit Breakers
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
David Mitchell

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.10.1-2018
IEEE Guide for the Selection of Monitoring for Circuit Breakers

Direction is provided for the selection of monitoring and for diagnostic parameters to be used with high-voltage circuit breakers (i.e., above 1000 V). Guidance on appropriate parameters to be considered for monitoring applied to various circuit breaker technologies is also provided.

Learn More About C37.10.1-2018

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.10.1-2000
IEEE Guide for the Selection of Monitoring for Circuit Breakers

This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Direction is provided for the selection of monitoring and for diagnostic parameters to be used with high-voltage circuit breakers (i.e., above 100 V). Guidance on appropriate parameters to be considered for monitoring applied to various circuit breaker technologies is also provided.

Learn More About C37.10.1-2000

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.