Active Standard

IEEE 8802-5 Amd 1-1998

ISO/IEC 8802-5:1998, Amd.1 (ANSI/IEEE Std 802.5 and 802.5j, 1998 Edition) Information Technology-Telecommunications and information exchange between systems-Local and metropolitan area networks-Specific requirements-Part 5: Token ring access method and physical layer specification-Amendment 1: Dedicated token ring operation and fiber optic media

This IEEE Standards product is part of the 802 family on LAN/MAN. This amendment to Local and Metropolitan Area Network standard, ISO/IEC 8802-5 : 1998, is part of a family of local area network (LAN) standards dealing with the physical and data link layers as defined by the ISO/IEC Open Systems Interconnection Basic Reference Model. The requirements for dedicated token ring (DTR) operation are specified, including the changes and additions to the Medium Access Control (MAC) layer to provide for an additional full-duplex mode of operation (switching), and for interconnection of shared LAN segments to switch ports. Also specified are the characteristics of a fibre optic interface for connecting a 4 Mbit/s or 16 Mbit/s token ring station to the trunk coupling unit (TCU) of a token ring, including station, port, and channel requirements. Fibre optic trunk signaling recommendations are also made.

Standard Committee
C/LAN/MAN - LAN/MAN Standards Committee
Status
Active Standard
History
Published:
1998-07-13

Working Group Details

Society
IEEE Computer Society
Standard Committee
C/LAN/MAN - LAN/MAN Standards Committee

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.