Made in this guide are suggestions on testing the dielectric strength of the insulation separating the various turns from each other within multi-turn form-wound coils to determine the acceptability of the coils. Typical ratings of machines employing such coils normally lie within the range of 200 kW to 100 MW. Test voltage levels described herein do not evaluate the ability of the turn insulation to withstand abnormal voltage surges, as contrasted to surges associated with normal operation. These suggestions apply to the following: a) Individual stator coils after manufacture b) Coils in completely wound stators of original manufacture c) Coils and windings for rewinds of used machinery d) Windings of machines in service to determine their suitability for further service (preventive-maintenance testing) The repetitive voltage surges (spikes) associated with Variable Frequency Drives (VFDs) are not addressed here.
- Sponsor Committee
- PE/EM - Electric Machinery
Learn More About PE/EM - Electric Machinery - Joint Sponsors
-
DEI/SC
- Status
- Active Standard
- PAR Approval
- 2016-12-07
- Superseding
- 522-2004
- Board Approval
- 2023-09-21
- History
-
- Published:
- 2023-10-30
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society - Sponsor Committee
- PE/EM - Electric Machinery
Learn More About PE/EM - Electric Machinery - Working Group
-
Matl - WG522 - Materials SC - Turn Insulation of Form-Wound Stator Coils
- IEEE Program Manager
- Malia Zaman
Contact Malia Zaman - Working Group Chair
- Paul Gaberson
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
522-2004
IEEE Guide for Testing Turn Insulation of Form-Wound Stator Coils for Alternating-Current Electric Machines
Revision of IEEE Std 522-1992 Suggestions are made for testing the dielectric strength of the insulation separating the various turns from each other within multiturn form-wound coils to determine their acceptability. Typical ratings of machines employing such coils normally lie within the range of 200 kW to 100 MW (270 hp to 135 000 hp). The test levels described do not evaluate the ability of the turn insulation to withstand abnormal voltage surges, only surges associated with normal operation. The suggestions apply to: (1) individual stator coils after manufacture; (2) coils in completely wound stators; (3) coils and windings for rewinds of used machinery; and (4) windings of machines in service to determine their suitability for further service (preventive-maintenance testing). Coil service conditions, test devices, and test sequence are discussed.