Active Standard

IEEE 1407-2021

IEEE Guide for Accelerated Aging Tests for 5 kV to 46 kV Extruded Electric Power Cables Using Water-Filled Tanks

Provided in this guide are information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis, and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.

Standard Committee
PE/IC - Insulated Conductors
Status
Active Standard
PAR Approval
2015-06-11
Superseding
1407-2007
Board Approval
2021-11-09
History
Published:
2022-02-03

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/IC - Insulated Conductors
Working Group
A13W/P1407_WG - Working Group for Aging Tests of MV Cables Using Water-Filled Tanks
IEEE Program Manager
Dalisa Gonzalez
Contact Dalisa Gonzalez
Working Group Chair
Detlef Wald

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


1407-2007
IEEE Guide for Accelerated Aging Tests for Medium-Voltage (5 kV-35 kV) Extruded Electric Power Cables Using Water-Filled Tanks

This guide provides information on the equipment, cable specimens, test conditions, and measurements to perform accelerated aging tests on medium-voltage cables using water-filled tanks, whether the test be a time to failure test or a test in which samples are aged for fixed times followed by a diagnostic test such as a step ac breakdown test. The guide identifies the critical test parameters and describes techniques for their measurement and control. The implementation of the techniques will facilitate a comparison of data obtained by different laboratories.

Learn More About 1407-2007

Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.