Superseded Standard

IEEE 1110-1991

IEEE Guide for Synchronous Generator Modeling Practices in Stability Analyses

Superseded by 1110-2002. Three direct-axis and four quadrature-axis models are categorized, along with the basic transient reactance model. Some of the assumptions made in using various models, including the basic model, are discussed, and the fundamental equations and concepts involved in generator/system interfacing are presented. The various attributes of power system stability are covered in a general way, with two basic approaches being recognized. The first is categorized under large-disturbance nonlinear analysis. The second approach considers small disturbances, where the corresponding dynamic equations are linearized. Applications of a range of generator models are discussed and treated. The manner in which generator saturation is treated in stability studies, both in the initialization process, as well as during large or small disturbance stability analysis procedures is addressed. Saturation functions that are derived either from test data or by the methods of finite elements are developed. Different saturation algorithms for calculating values of excitation and internal power angle, depending upon generator terminal conditions, are compared. The question of parameter determination is thoroughly covered. Two approaches in accounting for generator field and excitation system base quantities are identified. Conversion factors are given for transferring field parameters from one base to another for correct generator/excitation system interface modeling. Suggestions for modeling of negative field currents and other field circuit discontinuities are included.

Sponsor Committee
PE/EM - Electric Machinery
Status
Superseded Standard
Superseded by
1110-2002
Board Approval
1991-03-21
History
ANSI Approved:
1991-08-09
Published:
1991-11-18

Working Group Details

Society
IEEE Power and Energy Society
Sponsor Committee
PE/EM - Electric Machinery

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.