Superseded Standard

IEEE C37.20.1-1993

IEEE Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear

This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Low-voltage metal-enclosed switchgear, which can contain either stationary or draw out, manually or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal compartments, in three-pole, two-pole, or single-pole construction is covered. Rated maximum voltage levels can be 254 V, 508 V, or 635 Vac and 300/325 Vm 800V, 1000 V, 1600V, or 3200 Vdc. The continuous current ratings of the main bus in ac designs can be 1600 A, 2000 A, 2500 A, 4000 A, 6000 A, 8000 A, 10 000 A, or 12 000 A. The switchgear can also contain associated control, instruments, metering, protective, and regulating devices as necessary. The standard deals with service conditions, rating, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.

Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Status
Superseded Standard
Superseded by
C37.20.1-2002
Superseding
C37.20.1-1987
Board Approval
1993-09-15
History
ANSI Approved:
1994-06-03
Published:
1994-05-05
Reaffirmed:
1998-03-19

Additional Resources

Interpretation
C37.20.1-1993_interp.pdf

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.