Added in this amendment is a new sub-clause, 4.5 Saturated core secondary winding parameters, to IEEE C62.69(TM)-2016. Test methods, test circuits, measurement procedures, and result treatment to determine the secondary winding resistance and saturated core inductance are given.
Standards Committee | |
Status |
Active
|
Board Approval |
2017-03-23
|
History |
Published Date:2017-07-14
|
Additional Resources Details
PAR |
Working Group Details
Working Group |
LV3.6.2 - 3.6.2 LV Solid State Surge Protective Components WG
|
Working Group Chair |
Michael J Maytum
|
Standards Committee | |
Society | |
IEEE Program Manager | |
Active Projects |
This standard sets terms, test methods, test circuits, measurement procedures and preferred result values for silicon thyristor-based surge protective components used for overvoltage or overcurrent or both protection in low-voltage information technology communications system items.
The thyristor variants covered are:
Unidirectional characteristic
Bidirectional characteristic
Two terminal (diode) fixed voltage
Three or more terminal gate controlled
Integrated series diode types for low capacitance.
|
This standard sets terms, test methods, test circuits, measurement procedures, and preferred result values for two-terminal hybrid integrated circuit surge protective components (SPCs) containing gas discharge tube and metal oxide varistor technologies connected either in series or parallel. These SPCs are used in the construction of surge protective devices (SPDs) and equipment used in Information & Communications Technologies, (ICT) networks with voltages up to AC 1000 V and DC 1500 V, to mitigate overvoltage surges. Series connected gas discharge tube and metal oxide varistor configurations are applicable for AC mains surge protection and the tests reflect this use. Parallel connected gas discharge tube and metal oxide varistor configurations are suited to communications line surge protection and the tests reflect this use.
This standard contains information on
-- terminology;
-- letter symbols;
-- graphical symbols;
-- environments;
-- essential ratings and characteristics;
-- rating verification and characteristic measurement;
-- mechanical requirements and identification;
-- preferred values;
-- qualification.
|
|
Existing Standards |
Varistors for surge-protective applications on systems with dc to 420 Hz frequency and voltages equal to or less than 1000 V rms, or 1200 V dc, are covered. Definitions, service conditions, and a series of test criteria for determining the electrical characteristics of the varistors are provided. The tests are intended as design tests and provide a means of comparing various surge-protective devices.
|
A two-terminal avalanche junction surge suppressor for surge-protective application on systems with dc to 420-Hz frequency and voltages equal to or less than 1000 V rms or 1200 V dc is considered. The device is a single package that may be assembled from any combination of series and/or parallel diode chips. Definitions, service conditions, and a series of test criteria for determining its electrical characteristics are provided. These devices are used as surge diverters for limiting transient overvoltages in power and communications circuits.
|
|
This standard applies to two or three terminal, four or five layer, thyristor surge protection devices (SPDs) for application on systems with voltages equal to or less than 1000 V rms or 1200 V dc.
|
|
Applications information on fixed voltage and gated thyristor surge protective devices(SPDs) are provided. Key device parameters and their sensitivities are explained. Several worked telecommunication circuit design examples are given.
|
|
Superseded by C62.59-2019. Avalanche breakdown diodes used for surge protection in systems with voltages equal to or less than 1000 V rms or 1200 V dc are discussed in this standard. The avalanche breakdown diode surge suppressor is a semiconductor diode which can operate in either the forward or reverse direction of its V-I characteristic. This component is a single package, which may be assembled from any combination of series and/or parallel diode chips.
|
|
Applications information on fixed-voltage and gated-thyristor surge protective components (SPCs) is provided. Key device parameters and their sensitivities are explained. Several worked telecommunication circuit design examples are given.
|
|
Test methods and preferred values for metal-oxide varistor (MOV) surge protective components are covered in this standard and have the following main parameter ranges: packaging (leaded disc-type or surface mount), nominal varistor voltage (5 V to 1200 V), 8/20 surge current rating (10 A to 70 kA), and 8/20 clamping voltage (10 V to 3 kV). With appropriate component selection, these components could be used for the overvoltage protection of power and signal systems having continuous ac voltages (2.5 V rms to 750 V rms), steady-state dc voltages (3.3 V to 1000 V), and peak signal feed voltages (3.5 V to 850 V). Information is given on manufacturer type testing used to determine environmental performance and rated values.
|
|
The basic requirements to be met by series connected, solid-state, self-restoring overcurrent protectors (OCPs) for the protection of telecommunication equipment and lines are presented. This standard should be used for the harmonization of existing or future specifications issued by solid-state, self-restoring OCP manufacturers, telecommunication equipment manufacturers, administrations, or network operators.
|
|
Terms, test methods, test circuits, measurement procedures, and preferred result values for the surge mitigation parameters of isolating transformers used in networking devices and equipment are set in this standard. Three types of isolating transformer are considered: mains low frequency power, high frequency power (switching mode power supplies) and signal (e.g., Ethernet data).
|
|
Supersedes IEEE C62.35-2010 and IEEE C62.35-2010/Cor1-2018. The basic electrical parameters to be met by silicon PN junction voltage clamping components used for the protection of telecommunications equipment or lines from surges are defined in this standard. It is intended that this standard be used for the harmonization of existing or future specifications issued by PN diode surge protective component manufacturers, telecommunication equipment manufacturers, administrations, or network operators.
|
|
Superseded by C62.59-2019. Avalanche breakdown diodes used for surge protection on systems with voltages equal to or less than 1000 V rms or 1200 V dc are discussed in this standard. The avalanche breakdown diode surge suppressor is a semiconductor diode that can operate in either the forward or reverse direction of its V-I characteristic. This component is a single package, which may be assembled from any combination of series and/or parallel diode chips. This standard contains definitions, service conditions, and a series of test criteria for determining the electrical characteristics and verifying ratings of these avalanche breakdown diodes. If the characteristics differ with the direction of conduction, then each direction of conduction shall be separately specified.
|