Active Standard

IEEE C37.012-2014/Cor 1-2016

IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers above 1000 V - Corrigendum 1

This corrigendum addresses a change in Equation (26) and the list of variables belonging to this equation.

Sponsor Committee
PE/SWG - Switchgear
Learn More
Status
Active Standard
PAR Approval
2015-06-11
Board Approval
2016-01-29
History
Published:
2016-02-12

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/SWG - Switchgear
Learn More
Working Group
HVCB-WG_C37.012 - HVCB - IEEE Application Guide for Capacitance Current Switching for AC High-Voltage Circuit Breakers
Learn More
IEEE Program Manager
Jennifer Santulli
Contact
Working Group Chair
Roy Alexander

PC37.012

Guide for the Application of Capacitive Current Switching for AC High-Voltage Circuit Breakers Above 1000 V

This document provides a revised application guide for capacitive current switching for high-voltage circuit breakers rated in accordance with IEEE Std C37.04. It supplements IEEE Std C37.010. Circuit breakers rated and manufactured to meet other standards should be applied in accordance with application procedures adapted to their specific ratings.

Learn More

C37.012-2014

IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 V

Guidance for the application of ac high-voltage circuit breakers is provided. The application guide addresses the general theory of capacitance current switching; and the notions of re-strike, re-ignition, non-sustained disruptive discharge (NSDD). Voltage factors used for single-phase testing as substitute for three-phase testing are explained. Application of circuit breakers for different network conditions and different capacitive loads (capacitor banks, cables, transmission lines, and filter banks) is treated.

Learn More

C37.012a-2020

IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 V Amendment 1

Covered in this amendment are changes in di/dt limitations for non-oil circuit breakers. A section has been added describing possible delayed current zeros when doing a rapid close–open of a line circuit breaker (CO) when shunt reactors are connected to a line or cable. Some minor errors have been corrected and references have been updated.

Learn More

C37.012-2005

IEEE Application Guide for Capacitance Current Switching for AC High-Voltage Circuit Breakers

Guidance for the application of ac high-voltage circuit breakers for capacitance current switching is provided. The document addresses the general theory of capacitance current switching, the notion of restrike, reignition, NSDD and voltage factors are explained. Application of circuit breakers for different network conditions and different capacitive loads (lines, cables, capacitor and filter banks) is treated.