Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications

This recommended practice covers the sizing of nickel-cadmium batteries used for standby operation in stationary applications. Recommendations are provided for applications including, but not limited to, generating stations, substations, telecommunications, switchgear and control systems, compressor stations, emergency lighting, and uninterruptible power supplies. Guidance is provided for sizing for engine-starting applications. The following topics are beyond the scope of this document: Installation, maintenance, qualification, and testing procedures; Consideration of battery types other than nickel-cadmium; Renewable energy systems (e.g., wind turbines and photovoltaic systems) that may provide only partial or intermittent charging; Design of the dc system and sizing of the battery charger(s)

Sponsor Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Learn More
Status
Active PAR
PAR Approval
2022-11-10
Superseding
1115-2014

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Learn More
Working Group
WG_1115 - Ni-Cd Battery Sizing Working Group
Learn More
IEEE Program Manager
Michael Kipness
Contact
Working Group Chair
David Hood

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1115-2014

IEEE Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications

The sizing of nickel-cadmium batteries used in standby operation for stationary applications is discussed in this recommended practice.

Learn More

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1115-2000

IEEE Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications

The sizing of nickel-cadmium batteries used in full float operation for stationary applications is covered in this recommended practice.

Learn More

1115a-2007

IEEE Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications Amendment 1: Additional Discussion on Sizing Margins

This amendment provides additional guidance on sizing margins that may be applied when nickel-cadmium batteries are used in stationary applications involving an element of charge-discharge cycling.

Learn More

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.