C37.95-2014 - Guide for Protective Relaying of Utility-Consumer InterconnectionsDescribed in this guide are protective relay applications involving electric service to consumers that requires a transformation between the... Active Standard
C37.96-1988 - Guide for AC Motor ProtectionThis IEEE guide for the relay protection of squirrel-cage and wound-rotor induction motors and synchronous motors presents a review of the... Withdrawn Standard
C37.96-2000 - Guide for AC Motor ProtectionGenerally accepted methods of protection for AC motors are provided. This guide identifies and summarizes the functions necessary for adequate... Superseded Standard
C37.96-2012 - Guide for AC Motor ProtectionGenerally accepted methods of protection for ac motors are provided. The functions necessary for adequate protection of motors based on type, size... Active Standard
C37.97-1979 - Guide for Protective Relay Applications to Power System BusesA bus is a critical element of a power systems, as it is the point of convergence of many circuits-transmission, generation, or loads. Factors... Withdrawn Standard
C37.98-1987 - Standard Seismic Testing of RelaysThis standard specifies the procedures to be used in the seismic testing of relays used in power system facilities. It is concerned with the... Withdrawn Standard
C37.98-2013 - Seismic Qualification Testing of Protective Relays and Auxiliaries for Nuclear FacilitiesThe methods and conditions for seismic qualification of protective relays and auxiliaries such as test and control switches, terminal blocks, and... Active Standard
C37.99-1980 - Guide for Protection of Shunt Capacitor BanksThis guide has been prepared to assist in the effective application of relays and other devices for the protection of shunt capacitors used in... Superseded Standard
C37.99-1990 - Guide for the Protection of Shunt Capacitor BanksThis guide has been prepared to assist in the effective application of relays and other devices for the protection of shunt capacitors used in... Superseded Standard
C37.99-2000 - Guide for the Protection of Shunt Capacitor BanksThe protection of shunt power capacitor, filter banks are covered. Guidelines for reliable applications of protection methods intended for use in... Superseded Standard
C37.99-2012 - Guide for the Protection of Shunt Capacitor BanksThis guide applies to the protection of shunt power capacitor banks and filter capacitor banks. Included are guidelines for reliable applications... Active Standard
C37.100-1992 - Standard Definitions for Power SwitchgearIn this standard, terms that encompass the products with the scope of the C37 project are defined. These include power switchgear for switching,... Active Standard
C37.100.1-2007 - Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 VThis is a new standard written specifically to collect into one document the requirements that are common in many IEEE power switchgear standards.... Active Standard
C37.100d-1991 - Supplement to C37.100-1981, Standard Definitions for Power SwitchgearSupplement to IEEE C37.100-1981. Add definition "Initial Transient Recovery Voltage". Terms that encompass the products with the scope of the C37... Superseded Standard
C37.101-1985 - Guide for Generator Ground ProtectionThis guide has been prepared to aid in the application of relays and relaying schemes for the protection of synchronous generators for single... Superseded Standard
C37.101-1993 - Guide for Generator Ground ProtectionGuidance in the application of relays and relaying schemes for protection against stator ground faults on high-impedance grounded generators is... Superseded Standard
C37.101-2006 - Guide for Generator Ground ProtectionThe guide is intended to assist protection engineers in applying relays and relaying schemes for protection against stator ground faults on... Active Standard
C37.102-1987 - Guide for AC Generator ProtectionThe guide for the relay protection of synchronous generators presents a review of the generally accepted forms of protection for the generator and... Superseded Standard
C37.102-1995 - Guide for AC Generator ProtectionIn this IEEE standard a review of the generally accepted forms of relay protection for the synchronous generator and its excitation system is... Superseded Standard
C37.102-2007 - Guide for AC Generator ProtectionA review of the generally accepted forms of relay protection for the synchronous generator and its excitation system is presented. This guide is... Active Standard
C37.103-1990 - Guide for Differential and Polarizing Relay Circuit TestingThe following topics were dealt with: IEEE C37.103-1990, IEEE Guide for Differential and Polarizing Relay Circuit Testing, covers the testing and... Withdrawn Standard
C37.103-2004 - Guide for Differential and Polarizing Relay Circuit TestingThe issues concerning testing and verification of the correctness of differential and polarizing circuits are described and discussed in this... Active Standard
C37.104-2002 - Guide for Automatic Reclosing of Line Circuit Breakers for AC Distribution and Transmission LinesGuidelines for the application of automatic reclosing facilities to circuit breakers are established. Decisions concerning the use of such... Superseded Standard
C37.104-2012 - Guide for Automatic Reclosing of Circuit Breakers for AC Distribution and Transmission LinesCurrent reclosing practices for transmission and distribution lines are described. Application considerations and coordination practices of... Active Standard
C37.105-1987 - Qualifying Class 1E Protective Relays and Auxiliaries for Nuclear Power Generating StationsThe standard describes the basic principles, requirements, and methods for qualifying Class 1E protective relays and auxiliaries such as test and... Superseded Standard
C37.105-2010 - Qualifying Class 1E Protective Relays and Auxiliaries for Nuclear Power Generating StationsBasic principles, requirements, and methods for qualifying Class 1E protective relays and auxiliaries in nuclear power generating stations... Active Standard
C37.106-1987 - Guide for Abnormal Frequency Protection for Power Generating PlantsThe guide is intended for the protection engineer to assist in applying relays for the protection of generating plant equipment from damage caused... Superseded Standard
C37.106-2003 - Guide for Abnormal Frequency Protection for Power Generating PlantsThis guide has been prepared to assist the protection engineer in applying relays for the protection of generating plant equipment from damage... Active Standard
C37.108-1989 - Guide for the Protection of Network TransformersNetwork transformer vaults are fire retardant enclosures within buildings or adjacent to them that contain two or more power transformers. These... Superseded Standard
C37.108-2002 - Guide for the Protection of Network TransformersGuidelines for the application of network protectors are established. The use of network transformers and protectors with distributed resources is... Active Standard
C37.109-1988 - Guide for the Protection of Shunt ReactorsThis guide covers protection of shunt reactors used typically to compensate for capacitive shunt reactance of transmission lines. A survey of... Superseded Standard
C37.109-2006 - Guide for the Protection of Shunt ReactorsThe purpose of this guide is to provide users of shunt reactors acceptable methods and configurations for the protection of power system shunt... Active Standard
C37.110-1996 - Guide for the Application of Current Transformers Used for Protective Relaying PurposesThe characteristics and classification if current transformers (cts) used for protective relaying are described. This guide also describes the... Superseded Standard
C37.110-2007 - Guide for the Application of Current Transformers Used for Protective Relaying PurposesThe characteristics and classification of current transformers (CTs) used for protective relaying are described. This guide also describes the... Active Standard
C37.110-2007/Cor 1-2010 - Guide for the Application of Current Transformers Used for Protective Relaying Purposes Corrigendum 1: Corrections to Equation 18 and Equation 19Corrigendum to IEEE Std C37.110-2007. Errors in Equation (18) and Equation (19) are corrected by this corrigendum. Active Standard
C37.111-1991 - Standard Common Format for Transient Data Exchange (COMTRADE) for Power SystemsIn this standard a common format for the data files and exchange medium needed for the interchange of various types of fault, test, or simulation... Superseded Standard
C37.111-1999 - Standard Common Format for Transient Data Exchange (COMTRADE) for Power SystemsA common format for data files and exchange medium used for the interchange of various types of fault, test, or simulation data for electrical... Superseded Standard
C37.111-2013 - /IEC Measuring relays and protection equipment – Part 24: Common format for transient data exchange (COMTRADE) for power systemsAlso known as IEC 60255-24 Ed.2, this standard defines a format for files containing transient waveform and event data collected from power... Active Standard