Project Icon

Power and Energy Standards

Displaying results 641 - 680 of 954
Power and Energy Standards
Status Help
C37.06-2009 - IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 VThe preferred ratings of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial, and util ... active Standard
C37.06.1-2000 - American National Standard Guide for High-Voltage Circuit Breakers Rated on Symmetrical Current Basis Designated -Definite Purpose for Fast Transient Recovery Voltage Rise TimesThe purpose of this guide is to provide suggested values of fast transient recovery voltage rise time ratings. The proposed ratings wer ... withdrawn Standard
C37.06.1-2017 - IEEE Recommended Practice for Preferred Ratings for High-Voltage(>1000 volts) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise TimesThe preferred ratings of transformer-limited fault duty (fast transient recovery voltage rise times) of indoor and outdoor high-voltage ... active Standard
C37.09-1999 - IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisThe testing procedures for all high-voltage circuit breakers that include all voltage ratings above 1000 V ac and comprise both indoor a ... active Standard
C37.09-1999/Cor 1-2007 - IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis - Corrigendum 1Corrigendum to IEEE Std C37.09-1999. Reaffirmed September 2007. This corrigendum corrects technical and other non-editorial errors made ... active Standard
C37.09a-2005 - American National Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis Amendment 1: Capacitance Current SwitchingAmendment to Std. C37.09-1999. Reaffirmed September 2007. The scope of IEEE Std C37.09a-2005 is to incorporate IEC 62271-100 capacitanc ... active Standard
C37.10-2011 - IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker FailuresPractices and processes to perform, analyze, and report failure investigations of power circuit breakers are provided. active Standard
C37.010-2016 - IEEE Application Guide for AC High-Voltage Circuit Breakers > 1000 Vac Rated on a Symmetrical Current BasisThe application of indoor and outdoor high-voltage circuit breakers rated above 1000 Vac for use in commercial, industrial, and utility ... active Standard
C37.10.1-2000 - IEEE Guide for the Selection of Monitoring for Circuit BreakersThis IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Direction is provided for the se ... active Standard
C37.11-1957 - ASA American National Standard Requirements for Power Circuit Breaker ControlThe purpose of this standard is to establish basic requirements for power circuit breaker control schemes so that users and manufacturer ... withdrawn Standard
C37.011-2011 - IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit BreakersProcedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breaker ... active Standard
C37.11-2014 - IEEE Standard Requirements for Electrical Control for AC High-Voltage (>1000 V) Circuit BreakersStandard requirements for all types of electrical control circuits for ac high-voltage circuit breakers rated above 1000 V are given. Th ... active Standard
C37.12-2008 - IEEE Guide for Specifications of High-Voltage Circuit Breakers (over 1000 Volts)These specifications apply to all indoor and outdoor types of ac high-voltage circuit breakers rate above 1000 volts. this document is i ... active Standard
C37.012-2014 - IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 VGuidance for the application of ac high-voltage circuit breakers is provided. The application guide addresses the general theory of capa ... active Standard
C37.012-2014/Cor 1-2016 - IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers above 1000 V - Corrigendum 1This corrigendum addresses a change in Equation (26) and the list of variables belonging to this equation. active Standard
C37.12.1-2007 - IEEE Guide for High-Voltage (>1000 V)Circuit Breaker Instruction Manual ContentThis Guide provides a recommended table of contents for high-voltage circuit breaker instruction manuals. The Guide provides a listing o ... active Standard
C37.13-2015 - IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in EnclosuresThe following enclosed low-voltage ac power circuit breakers are covered in this standard: a) stationary or drawout type of two-, three- ... active Standard
C37.13.1-2016 - IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage (600 V AC and Below) Power Circuit Breaker SwitchgearDefinite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear are covered in this standard. ... active Standard
C37.14-2015 - IEEE Standard for DC (3200 V and below) Power Circuit Breakers Used in EnclosuresEnclosed dc power circuit breakers of the stationary or drawout 32 type of one- or two-pole construction with one or more rated maximum ... active Standard
C37.015-2017 - IEEE Approved Draft Guide for the Application of Shunt Reactor SwitchingGuidance for the application of ac high-voltage circuit breakers for shunt reactor switching is provided. Overvoltage generation for the ... active Standard
C37.016-2006 - IEEE Standard for AC High Voltage Circuit Switchers rated 15.5kV through 245kVThis Standard is applicable to AC circuit switchers designed for outdoor installation and for rated power frequencies of 50 and 60 Hz an ... active Standard
C37.017-2010 - IEEE Standard for Bushings for High-Voltage [over 1000 V (ac)] Circuit Breakers and Gas-Insulated SwitchgearThis standard is applicable to bushings intended for use in high-voltage circuit breakers and gas-insulated switchgear. These bushings a ... active Standard
C37.17-2012 - IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit BreakersRequirements for direct acting current and voltage protective functions of direct-acting overcurrent electromechanical trip devices, dir ... active Standard
C37.18-1979 - IEEE Standard Enclosed Field Discharge Circuit Breakers for Rotating Electric MachineryLow-voltage power circuit breakers that are intended for use in field circuits of apparatus such as generators, motors, synchronous cond ... withdrawn Standard
C37.19-1963 - ASA American National Standard Safety Requirements for Standard for Low-Voltage AC Power Circuit Breakers and Switchgear AssembliesThis standard covers the following equipment. 19-1.1 Low-Voltage AC Power Circuit Breakers. Low-voltage ac power circuit breakers (not m ... withdrawn Standard
C37.20.1-2015 - IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker SwitchgearMetal-enclosed, low-voltage switchgear—which contains either stationary or drawout, manually or electrically operated low-voltage ac o ... active Standard
C37.20.2-2015 - IEEE Standard for Metal-Clad SwitchgearMetal-clad (MC) medium-voltage switchgear that contains drawout electrically operated circuit breakers is covered. MC switchgear is comp ... active Standard
C37.20.3-2013 - IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV–38 kV)Metal-enclosed interrupter (MEI) switchgear assemblies containing, but not limited to, such devices as interrupter switches; selector sw ... active Standard
C37.20.4-2013 - IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed SwitchgearIndoor ac medium-voltage switches for use in enclosures for application in power circuits at voltages above 1 kV through 38 kV are cover ... active Standard
C37.20.6-2015 - IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in EnclosuresDrawout-type ground and test devices for use in medium-voltage metal-clad switchgear rated 4.76 kV through 38 kV are covered. The descri ... active Standard
C37.20.7-2017 - IEEE Guide for Testing Switchgear Rated Up to 52 kV for Internal Arcing FaultsProcedures for testing and evaluating the performance of switchgear for internal arcing faults is covered. A method of identifying the c ... active Standard
C37.20.10-2016 - IEEE Standard Definitions for AC (52 kV and below)and DC (3.2 kV and below) Switchgear AssembliesTerms and definitions encompassing the products within the scope of ac (38 kV and below for air insulated equipment, 52 kV and below for ... active Standard
C37.21-2017 - IEEE Standard for Control SwitchboardsRatings, construction, and testing of dead-front control switchboards containing, but not limited to, devices such as switches, control ... active Standard
C37.22-1959 - ASA Automatic Circuit Reclosers and Automatic Line Sectionalizers for Alternating Current Systems1.1 This standard applies to all single- or multi-pole alternating-current automatic circuit reclosers and automatic line sectionalizers ... withdrawn Standard
C37.23-2015 - IEEE Standard for Metal-Enclosed BusMetal-enclosed (ME) bus assemblies for indoor and outdoor use are discussed in this standard. The types of assemblies covered are nonseg ... active Standard
C37.24-2017 - IEEE Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed SwitchgearInformation to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear including metal-enclosed bus and ... active Standard
C37.26-2014 - IEEE Guide for Methods of Power-Factor Measurement for Low-Voltage (1000 V AC or lower) Inductive Test CircuitsMethods for determining the value of the power factor for inductive low-voltage (1000 V ac and lower) test circuits are provided. These ... active Standard
C37.27-2015 - IEEE Guide for Low-Voltage AC (635 V and below) Power Circuit Breakers Applied with Separately-Mounted Current-Limiting FusesApplication recommendations to assist in selection of separately mounted current-limiting fuses to be installed in series with low-volta ... active Standard
C37.29-1981 - IEEE Standard for Low-Voltage AC Power Circuit Protectors Used in EnclosuresThis standard covers enclosed low-voltage ac power circuit protectors that are manually operated or power operated. Addressed are circui ... withdrawn Standard