400-2001 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable SystemsThis guide lists the various field test methods that are currently available or under development with guidance on HOW to perform each test. The... Superseded Standard
400-2012 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and AboveVarious field test methods that are currently available or under development are listed in this guide. The guide covers shielded, insulated power... Active Standard
400.1-2007 - Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current VoltageThe recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power... Active Standard
400.2-2004 - Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)This guide describes very low frequency (VLF) withstand and diagnostic tests and the measurements that are performed in the field on shielded... Superseded Standard
400.3-2006 - Guide for Partial Discharge Testing of Shielded Power Cable Systems in a Field EnvironmentThis guide covers the diagnostic testing of new or service-aged installed shielded power cable systems, which include cable, joints, and... Active Standard
402-1974 - Guide for Measuring Resistivity of Cable-Insulation Materials at High Direct Voltages1/92 memo from S. Vogel - Reaff in progress. Submittal expected June 1992 Withdrawn Standard
404-2006 - Extruded and Laminated Dielectric Shielded Cable Joints Rated 2 500v to 500 000vElectrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage... Superseded Standard
404-1986 - Cable Joints for Use with Extruded Dielectric Cable Rated 5000 V through 46 000 V and Cable Joints for Use with Laminated Dielectric Cable Rated 2500 V Through 500 000 VTo assure that the performance of the cable joint will equal the performance of the cable it joins electrical ratings and test requirements are... Superseded Standard
404-1993 - Cable Joints for Use With Extruded Dielectric Cable Rated 5000-138 000 V and Cable Joints for Use With Laminated Dielectric Cable Rated 2500-500 000 VThis standard establishes electrical ratings and test requirements for cable joints for use with extruded dielectric shielded cable rated in... Superseded Standard
404-2000 - Extruded and Laminated Dielectric Shielded Cable Joints Rated 2500-500 000VThis standard establishes electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable... Superseded Standard
421.3-1997 - High-Potential Test Requirements for Excitation Systems for Synchronous MachinesHigh-potential test voltages for excitation systems used with synchronous machines are established. Test voltages are established based on whether... Active Standard
421.5-1992 - Recommended Practice for Excitation System Models for Power System Stability StudiesExcitation system models suitable for use in large scale power system stability studies are presented. With these models, most of the excitation... Superseded Standard
421.5-2005 - Recommended Practice for Excitation System Models for Power System Stability StudiesExcitation system models suitable for use in large-scale system stability studies are presented. Important limiters and supplementary controls are... Active Standard
428-1981 - Standard Definitions and Requirements for Thyristor AC Power ControllersThese recommendations apply to thyristor AC power controllers that are low voltage, power electronic, industrial class equipment for the control... Withdrawn Standard
429-1994 - Recommended Practice for Thermal Evaluation of Sealed Insulation Systems for AC Electric Machinery Employing Form-Wound Preinsulated Stator Coils for Machines Rated 6900 V and BelowIn this IEEE standard a test procedure for comparing two or more sealed insulation systems in accordance with their expected life at rated... Withdrawn Standard
430-1986 - Standard Procedures for the Measurement of Radio Noise from Overhead Power Lines and SubstationsThe primary purpose of this standard is to establish uniform procedures for the measurement of radio noise generated by corona from overhead power... Withdrawn Standard
432-1976 - Guide for Insulation Maintenance for Rotating Electrical Machinery (5 hp to less than 10 000 hp)This insulation maintenance guide is intended to apply in general to industrial air-cooled rotating electrical machines rated from 5 hp to 10000... Superseded Standard
432-1992 - Guide for Insulation Maintenance for Rotating Electric Machinery (5 hp to less than 10 000 hp)In this standard, information necessary to permit an effective evaluation of the insulation systems of medium and small rotating electric machines... Withdrawn Standard
433-1974 - Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low FrequencyThis document provides a uniform method of VLF testing in order to obtain consistent results, accumulate meaningful experience, and lead to... Withdrawn Standard
434-1973 - Guide for Functional Evaluation of Insulation Systems for Large High-Voltage MachinesThe purpose of this guide is to describe classification test methods which may be used to compare insulation systems in use, or proposed for use,... Superseded Standard
434-2006 - Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and AboveA procedure that may be used to evaluate and compare insulation systems used, or proposed for use, in large ac electric machines is described in... Active Standard
436-1977 - Guide for Making Corona (Partial Discharge) Measurements on Electronics TransformersThis guide covers the detection of corona and the measurement of corona magnitude in electronics transformers. Test conditions, terminology, test... Superseded Standard
436-1991 - Guide for Making Corona (Partial Discharge) Measurements on Electronics TransformersA uniform procedure for making corona (partial discharge) measurements by electrical means on electronic transformers is presented. Methods of... Active Standard
442-1981 - Guide for Soil Thermal Resistivity MeasurementsThis guide covers the measurement of soil thermal resistivity. A thorough knowledge of the thermal properties of a soil will enable the user to... Active Standard
444-1973 - Standard Practices and Requirements for Thyristor Converters for Motor Drives Part 1- Converters for DC Motor Armature SuppliesThis standard applies to all types of line-commutated semiconductor power converters, employing monocrystalline semiconductor thyristors or diodes... Withdrawn Standard
446-1987 - Recommended Practice for Emergency and Standby Power Systems for Industrial and Commerical ApplicationsRecommended engineering principles, practices, and guidelines for the selection and application of emergency and standby power systems are... Superseded Standard
446-1995 - Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial ApplicationsThis Recommended Practice addresses the uses, power sources, design, and maintenance of emergency and standby power systems. Chapter 3 is a... Active Standard
449-1990 - Ferroresonant Voltage RegulatorsThis standard pertains to ferroresonant voltage regulators that operate at relatively constant frequencies and provide substantially constant... Withdrawn Standard
449-1998 - Ferroresonant Voltage RegulatorsFerroresonant transformers used as regulators in electronic power supplies and in other equipment are covered. Guides to application and test... Active Standard
450-1987 - Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and SubstationsThis recommended practice is limited to providing recommended practices of maintenance, test schedules, and testing procedures than can be used to... Superseded Standard
450-1995 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-2002 - Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
455-1985 - Standard Test Procedure for Measuring Longitudinal Balance of Telephone Equipment Operating in the Voice BandThe purpose of this standard is threefold: to define the basic requirements of a test circuit which can be used to measure longitudinal balance.... Withdrawn Standard
460-1988 - Electrical Measuring Transducer for Converting AC Electrical Quantities into DC Electrical QuantitiesThis standard applies to measuring transducers used for converting AC electrical quantities such as current, voltage, power (active or reactive),... Withdrawn Standard
463-1977 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesThis standard covers means of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones.... Superseded Standard
463-1993 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided. Included... Withdrawn Standard
463-2006 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans for improved safeguarding of personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided... Superseded Standard
475-2000 - Standard Measurement Procedure for Field Disturbance Sensors 300 MHz to 40 GHzTest procedures for microwave field disturbance sensors to measure radio frequency (RF) radiated field strength of the fundamental frequency,... Active Standard