Active Standard

IEEE C57.123-2019

IEEE Guide for Transformer Loss Measurement

Information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, and load losses of power and distribution transformers are provided. The guide is intended as a complement to the test code procedures given in Clause 8 and Clause 9 of IEEE Std C57.12.90.

Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Status
Active Standard
PAR Approval
2017-06-15
Superseding
C57.123-2010
Board Approval
2019-11-07
History
Published:
2020-02-10

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Working Group
PerfCharac-WGC57.123 - Performance Characteristics - Xfrmr Loss Measurement Working Group
IEEE Program Manager
Malia Zaman
Contact Malia Zaman
Working Group Chair
Ed TeNyenhuis

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C57.123-2002

IEEE Guide for Transformer Loss Measurement

Information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, and loadlosses of power and distribution transformers are provided. The guide is intended as a complement to the test code procedures given in Clause 8 and Clause 9 of IEEE Std C57.12.90-1999.

Learn More About C57.123-2002

C57.123-2010

IEEE Guide for Transformer Loss Measurement

Information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, and load losses of power and distribution transformers are provided. The guide is intended as a complement to the test code procedures given in Clause 8 and Clause 9 of IEEE Std C57.12.90.

Learn More About C57.123-2010

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.