SysName |
REFID |
Mnemonic |
Description |
PART |
CODE10 |
12-lead, unspecified | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_UNSPECIFIED |
SCP_12LD_0 |
Unspecified. Systems that do not record the electrode placement information should use this term. |
10 |
11264 |
12-lead, standard | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD |
SCP_12LD_1 |
Standard 12-lead positions: RA, RL, LA, and LL are placed at limb extremities. V1 to V6 at standard positions on the chest. All electrodes are placed individually. This lead positioning supports the standard 12 leads I, II, III, aVR, aVL, aVR, V1, V2, V3, V4, V5, V6 and the Cabrera 12 leads aVL, I, aVR, II, aVF, III, V1, V2, V3, V4, V5, V5, V6. |
10 |
11265 |
12-lead, Mason-Likar | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_MASON_LIKAR |
SCP_12LD_2 |
RA, RL, LA, and LL are placed on the torso (Mason-Likar positions). V1 to V6 are placed at standard positions on the chest. All electrodes are placed individually. |
10 |
11266 |
12-lead, V-Pad | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_VPAD |
SCP_12LD_3 |
RA, RL, LA, and LL are placed on the torso (Mason-Likar positions). These limb electrodes are individually placed. V1 to V6 on the chest as part of a single electrode pad (V1 to V6 are NOT placed individually). |
10 |
11267 |
12-lead, Pad | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_PAD |
SCP_12LD_4 |
RA, RL, LA, LL, and V1 to V6 (all electrodes) are on the chest in a single electrode pad (such as Omnitrode). (None of the electrodes are placed individually) |
10 |
11268 |
12-lead from Frank XYZ | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_FROM_FRANK |
SCP_12LD_5 |
12-lead ECG is derived from Frank XYZ leads |
10 |
11269 |
12-lead, non-standard | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_NON_STANDARD |
SCP_12LD_6 |
12-lead ECG is derived from non-standard leads |
10 |
11270 |
12-lead, bicycle | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_BICYCLE |
|
Standard leads for bicycle exercise testing in Europe (Germany, Finland,..) where bicycle tests in upright position are performed the limb leads are often positioned not on the chest (Mason-Likar), but on the back (shoulder and on the hips) of the patient. Doing this has a practical reason, since the patient bows his back during bicycling and the limb lead electrodes applied on the chest would be disturbed. |
10 |
11271 |
12-lead, raised intercostal | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_RAISED_INTERCOSTAL |
|
Standard leads one intercostal space higher. The Wilson electrodes are applied one intercostal space higher the limb electrodes remain on their position. I..aVF, V1', V2' ... V6'. |
10 |
11272 |
XYZ, unspecified | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_XYZ_UNSPECIFIED |
SCP_XYZ_0 |
Unspecified. Systems that do not record the electrode placement information should use this term. |
10 |
11273 |
XYZ, Frank | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_XYZ_FRANK |
SCP_XYZ_1 |
Frank lead system (Frank, E., An accurate clinically practical system for spatial vectorcardiography. Circulation 13:737, 1956). |
10 |
11274 |
XYZ, McFee-Parungao | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_XYZ_MCFEE_PARUNAGO |
SCP_XYZ_2 |
McFee-Parungao lead system (see Benchimol, Vectorcardiography, Williams & Wilkins, Baltimore, 1973, Fig 1.6 on page 6) |
10 |
11275 |
XYZ, Cube |
MDC_ECG_LDSYS_XYZ_CUBE |
SCP_XYZ_3 |
Cube lead system (Grishman et al, Amer Heart J 1951; 41:483). |
10 |
11276 |
XYZ, Bipolar |
MDC_ECG_LDSYS_XYZ_BIPOLAR |
SCP_XYZ_4 |
Bipolar uncorrected XYZ lead system |
10 |
11277 |
XYZ, Pseudo-Orthogonal |
MDC_ECG_LDSYS_XYZ_PSEUDO_ORTH |
SCP_XYZ_5 |
Pseudo-orthogonal XYZ lead system (as used in Holter recording) |
10 |
11278 |
XYZ, from 12-lead |
MDC_ECG_LDSYS_XYZ_FROM_12LD |
SCP_XYZ_6 |
XYZ leads derived from standard 12-lead ECG |
10 |
11279 |
3-lead, NEHB | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_3LD_NEHB |
|
NEHB lead system (see also Annex CC of IEC 60601-2-51) |
10 |
11280 |
3-lead, CC5-CM5-ML | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_3LD_CC5_CM5_ML |
|
First electrode at mid-sternum at the second intercostal space and second electrode in the fifth intercostal space in the anterior axillary line (V5R/C5R). |
10 |
11281 |
3-lead, CM5-CC5-CH5 | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_3LD_CM5_CC5_CH5 |
|
First electrode at mid-sternum at the second intercostal space; second electrode in the fifth intercostal space in the anterior axillary line (V5R/C5R) and third electrode on either side of neck above shoulders. |
10 |
11282 |
12-lead from Dower | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_FROM_DOWER |
|
12-lead from Frank leads (X, Y, Z) leads by Dower transformation |
10 |
11283 |
12-lead from EASI | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_FROM_EASI |
|
12-lead from EASI leads (ES, AS, AI) by Dower/EASI transformation |
10 |
11284 |
12-lead from Limb | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_FROM_LIMB |
|
12-lead from Limb Leads (I, II) and one or more V leads |
10 |
11285 |
12-lead and XYZ | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_AND_XYZ |
|
Standard 12-lead and XYZ |
10 |
11286 |
12-lead and NEHB | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_AND_NEHB |
|
Standard 12-lead and NEHB |
10 |
11287 |
12-lead and CC5-CM5-ML | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_AND_CC5_CM5_ML |
|
Standard 12-lead and CC5-CM5-ML |
10 |
11288 |
12-lead and CM5-CC5-CH5 | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_AND_CM5_CC5_CH5 |
|
Standard 12-lead and CM5-CC5-CH5 |
10 |
11289 |
12-lead extended | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_EXTD |
|
Standard 12-lead with extra leads to the right and/or left sides, specified by their lead labels |
10 |
11290 |
12-lead extended right | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_EXTD_RIGHT |
|
Standard 12-lead extended to the right by V5R, V4R, V3R (see Annex CC of IEC 60601-2-51) |
10 |
11291 |
12-lead extd left | ECG, lead system | Heart | CVS |
MDC_ECG_LDSYS_12LD_STD_EXTD_LEFT |
|
Standard 12-lead extended to the left by V7, V8, V9 (see Annex CC of IEC 60601-2-51) |
10 |
11292 |