Displaying results 1 - 40 of 162
Standard Name
Status Help less all
1127-2013 - Guide for the Design, Construction, and Operation of Electric Power Substations for Community Acceptance and Environmental CompatibilitySignificant community acceptance and environmental compatibility items to be considered during the planning and design phases, the construction... Active Standard
1377-2012 - Utility Industry Metering Communication Protocol Application Layer (End Device Data Tables)Common structures are provided in this standard for encoding data in communication between End Devices (meters, home appliances, IEEE 1703 Nodes)... Active Standard
1901.2-2013 - Low-Frequency (less than 500 kHz) Narrowband Power Line Communications for Smart Grid ApplicationsA worldwide standard for narrowband power line communications (PLC) via alternating current, direct current, and nonenergized electric power lines... Active Standard
81-2012 - Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding SystemPractical test methods and techniques are presented for measuring the electrical characteristics of grounding systems. Topics addressed include... Active Standard
1711-2010 - Trial-Use a Cryptographic Protocol for Cyber Security of Substation Serial LinksA cryptographic protocol to provide integrity, and optional confidentiality, for cyber security of serial links is defined in this trial use... Withdrawn Standard
1901-2010 - Broadband over Power Line Networks: Medium Access Control and Physical Layer SpecificationsA standard for high-speed communication devices via electric power lines, so called broadband over power line (BPL) devices, is defined.... Active Standard
C37.239-2010 - Common Format for Event Data Exchange (COMFEDE) for Power SystemsA common format for data files used for the interchange of various types of event data collected from electrical power systems or power system... Active Standard
802.15.4-2011 - Part 15.4: Low-Rate Wireless Personal Area Networks (LR-WPANs)The protocol and compatible interconnection for data communication devices using low-data-rate, low-power, and low-complexity short-range radio... Active Standard
802.15.4g-2012 - Part 15.4: Low-Rate Wireless Personal Area Networks (LR-WPANs) Amendment 3: Physical Layer (PHY) Specifications for Low-Data-Rate, Wireless, Smart Metering Utility NetworksIn this amendment to IEEE Std 802.15.4-2011, outdoor low-data-rate, wireless, smart metering utility network requirements are addressed. Alternate... Active Standard
1701-2011 - Optical Port Communication Protocol to Complement the Utility Industry End Device Data TablesThis standard provides multi-source and "plug and play" environment for the millions of metering devices in the field now and the future using the... Active Standard
1702-2011 - Telephone Modem Communication Protocol to Complement the Utility Industry End Device Data TablesThis standard provides multisource and "plug and play" environment for the millions of metering devices in the field now and in the future using... Active Standard
802.3-2012 - EthernetEthernet local area network operation is specified for selected speeds of operation from 1 Mb/s to 100 Gb/s using a common media access control ... Active Standard
C37.232-2011 - Common Format for Naming Time Sequence Data Files (COMNAME)A standard procedure for naming time sequence data (TSD) files, such as files produced by digital fault recorders, power swing recorders, power... Active Standard
1031-2011 - Guide for the Functional Specification of Transmission Static Var CompensatorsAn approach to preparing a specification for a transmission static var compensator is documented by this guide. The intention of this document is... Active Standard
1020-2011 - Guide for Control of Small (100 kVA to 5 MVA) Hydroelectric Power PlantsDescription of the electrical control and monitoring requirements for equipment and systems associated with small (100 kVA to 5 MVA) hydroelectric... Active Standard
1409-2012 - Guide for Application of Power Electronics for Power Quality Improvement on Distribution Systems Rated 1 kV Through 38 kVGuidelines and performance expectations are provided for the application of power electronic-based equipment on distribution systems of power... Active Standard
802.16-2012 - Air Interface for Broadband Wireless Access SystemsThis standard specifies the air interface, including the medium access control layer (MAC) and physical layer (PHY), of combined fixed and mobile... Active Standard
1888.1-2013 - Ubiquitous Green Community Control Network: Control and ManagementThis standard describes network gateway access, control, and management; specifies control and management requirements; defines the system... Active Standard
1888.2-2014 - Approved Draft Ubiquitous Green Community Control Network: Heterogeneous Networks Convergence and ScalabilityThis standard describes heterogeneous networks convergence and scalability, specifies the requirements of networks convergence, extends the system... Active Standard
1888.3-2013 - Ubiquitous Green Community Control Network: SecurityThe enhanced security management function for the protocol defined in IEEE 1888(TM), “Ubiquitous Green Community Control Network Protocol,” is... Active Standard
1686-2013 - Intelligent Electronic Devices Cyber Security CapabilitiesThe functions and features to be provided in intelligent electronic devices (IEDs) to accommodate critical infrastructure protection programs are... Active Standard
802-1955 - AIEE Proposed Trail Use Test Code DIRECT -- CURRENT CARBON -- PILE VOLTAGE REGULATORS for AIRCRAFTIt is the purpose of this code to define uniform acceptable methods of making tests to determine that the rating, performance and other... Active Standard
1703-2012 - Local Area Network/Wide Area Network (LAN/WAN) Node Communication Protocol to Complement the Utility Industry End Device Data TablesA set of application layer messaging services are provided in this standard that are applicable for the enterprise and End Device ends of an... Active Standard
C62.39-2012 - Test Methods and Preferred Values for Self-Restoring Current-Limiter Components Used in Telecommunication Surge ProtectionThe basic requirements to be met by series connected, solid-state, self-restoring overcurrent protectors (OCPs) for the protection of... Active Standard
1888-2014 - Approved Draft Ubiquitous Green Community Control Network ProtocolThe standard identifies gateways for field-bus networks, data storages for archiving and developing data sharing platform, and application units... Active Standard
80-1986 - Guide for Safety in AC Substation GroundingThe third edition of this guide represents the first major revision since its first issue in 1961. Major modifications include the redefinition of... Superseded Standard
80-2000 - Guide for Safety in AC Substation GroundingOutdoor ac substations, either conventional or gas-insulated, are covered in this guide. Distribution, transmission, and generating plant... Superseded Standard
80-2013 - Approved Draft Guide for Safety in AC Substation GroundingThis guide is primarily concerned with outdoor AC substatons, either air-insulated or gas-insulated. Distribution, transmission and power plant... Active Standard
81-1983 - Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System Part 1: Normal MeasurementsThe technique of measuring ground resistance and impedance, earth resistivity, potential gradients from currents in the earth, and the prediction... Superseded Standard
81.2-1991 - Guide for Measurement of Impedance and Safety Characteristics of Large, Extended or Interconnected Grounding SystemsThe purpose of this guide is to present practical instrumentation methods that may be used for the measurement of impedance to remote earth, step... Withdrawn Standard
367-1987 - Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power FaultWire-line telecommunication facilities serving electric power stations often require that extraordinary protection measures be taken to protect... Superseded Standard
367-1996 - Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power FaultGuidance for the calculation of power station ground potential rise (GPR) and longitudinal induction (LI) voltages is provided, as well as... Superseded Standard
367-2012 - Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power FaultGuidance for the calculation of power station ground potential rise (GPR) and longitudinal induction (LI) voltages is provided, as well as... Active Standard
487-1980 - Guide for the Protection of Wire-Line Communication Facilities Serving Electric Power StationsWire-line communication facilities serving electric power stations often require special high-voltage protection against the effects of fault... Superseded Standard
487-1992 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Power StationsWorkable methods for protecting wire-line communication circuits entering power stations are presented. This standard covers: the electric power... Superseded Standard
487-2000 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply LocationsWorkable methods for protecting wire-line communication circuits entering electric supply locations are presented. This document covers: the... Superseded Standard
487-2007 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply LocationsWorkable methods for protecting wire-line communication circuits entering electric supply locations are presented. This document covers: the... Active Standard
644-1987 - Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power LinesEstablishes uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current (AC) overhead power... Withdrawn Standard
644-1994 - Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power LinesIn this IEEE Standard uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current (AC)... Active Standard
656-1985 - the Measurement of Audible Noise from Overhead Transmission LinesThe purpose of this standard is to establish uniform procedures for the measurement of audible noise from overhead transmission lines, using... Superseded Standard
Displaying results 1 - 40 of 162 - all results