Standard Icon

Power and Energy Standards

Displaying results 321 - 360 of 1335
Standard Name
Status Help less all
436-1977 - Guide for Making Corona (Partial Discharge) Measurements on Electronics TransformersThis guide covers the detection of corona and the measurement of corona magnitude in electronics transformers. Test conditions, terminology, test... Superseded Standard
436-1991 - Guide for Making Corona (Partial Discharge) Measurements on Electronics TransformersA uniform procedure for making corona (partial discharge) measurements by electrical means on electronic transformers is presented. Methods of... Active Standard
442-1981 - Guide for Soil Thermal Resistivity MeasurementsThis guide covers the measurement of soil thermal resistivity. A thorough knowledge of the thermal properties of a soil will enable the user to... Active Standard
444-1973 - Standard Practices and Requirements for Thyristor Converters for Motor Drives Part 1- Converters for DC Motor Armature SuppliesThis standard applies to all types of line-commutated semiconductor power converters, employing monocrystalline semiconductor thyristors or diodes... Withdrawn Standard
446-1987 - Recommended Practice for Emergency and Standby Power Systems for Industrial and Commerical ApplicationsRecommended engineering principles, practices, and guidelines for the selection and application of emergency and standby power systems are... Superseded Standard
446-1995 - Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial ApplicationsThis Recommended Practice addresses the uses, power sources, design, and maintenance of emergency and standby power systems. Chapter 3 is a... Active Standard
449-1990 - Ferroresonant Voltage RegulatorsThis standard pertains to ferroresonant voltage regulators that operate at relatively constant frequencies and provide substantially constant... Withdrawn Standard
449-1998 - Ferroresonant Voltage RegulatorsFerroresonant transformers used as regulators in electronic power supplies and in other equipment are covered. Guides to application and test... Active Standard
450-1987 - Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and SubstationsThis recommended practice is limited to providing recommended practices of maintenance, test schedules, and testing procedures than can be used to... Superseded Standard
450-1995 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-2002 - Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
460-1988 - Electrical Measuring Transducer for Converting AC Electrical Quantities into DC Electrical QuantitiesThis standard applies to measuring transducers used for converting AC electrical quantities such as current, voltage, power (active or reactive),... Withdrawn Standard
463-1977 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesThis standard covers means of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones.... Superseded Standard
463-1993 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided. Included... Withdrawn Standard
463-2006 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans for improved safeguarding of personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided... Active Standard
467-1980 - Standard Quality Assurance Program Requirements for the Design and Manufacture of Class 1E Instrumentation and Electric Equipment for Nuclear Power Generating StationsThis standard establishes the basic Quality Assurance Program requirements to be implemented by manufacturers of Class 1E Instrumentation and... Withdrawn Standard
484-2002 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary ApplicationsRecommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of... Active Standard
484-1987 - Recommended Practice for Installation Design and Installation of Large Lead Storage Batteries for Generating Stations and SubstationsProvides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly and... Superseded Standard
484-1996 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary ApplicationsIn this IEEE Standard recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
485-1983 - Recommended Practice for Sizing Large Lead Storage Batteries for Generating Stations and SubstationsMethods for defining the dc load in a generating station or a substation and for sizing a lead storage battery to supply that load are described.... Superseded Standard
485-1997 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary ApplicationsMethods for defining the DC load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float... Superseded Standard
485-2010 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary ApplicationsMethods for defining the direct current (dc) load and for sizing a lead-acid battery to supply that load for stationary battery applications in... Active Standard
487-1980 - Guide for the Protection of Wire-Line Communication Facilities Serving Electric Power StationsWire-line communication facilities serving electric power stations often require special high-voltage protection against the effects of fault... Superseded Standard
487-1992 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Power StationsWorkable methods for protecting wire-line communication circuits entering power stations are presented. This standard covers: the electric power... Superseded Standard
487-2000 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply LocationsWorkable methods for protecting wire-line communication circuits entering electric supply locations are presented. This document covers: the... Superseded Standard
487-2007 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply LocationsWorkable methods for protecting wire-line communication circuits entering electric supply locations are presented. This document covers: the... Active Standard
492-1974 - Guide for Operation and Maintenance of Hydro-GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of hydro-generators and generator/motors (pump/turbines),... Withdrawn Standard
492-1999 - Guide for Operation and Maintenance of Hydro-GeneratorsGeneral recommendations for the operation, loading and maintenance of synchronous hydroelectric generators and generator/motors are covered. This... Active Standard
493-1980 - Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (IEEE Gold Book)Superseded. The fundamentals of reliability analysis as it applies to the planning and design of industrial and commercial electric power... Superseded Standard
493-1990 - Recommended Practice for the Design of Reliable Industrial and Commercial Power SystemsThe fundamentals of reliability analysis as it applies to the planning and design of industrial and commercial electric power distribution systems... Superseded Standard
493-1997 - Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (Gold Book)The fundamentals of reliability analysis as it applies to the planning and design of industrial and commercial electric power distribution systems... Superseded Standard
493-2007 - Recommended Practice for the Design of Reliable Industrial and Commercial Power SystemsThe objective of this book is to present the fundamentals of reliability analysis applied to the planning and design of industrial and commercial... Active Standard
494-1974 - Standard Method for Identification of Documents Related to Class 1E Equipment and Systems for Nuclear Power Generating StationsThis IEEE standard establishes criteria for the uniform identification of documents significant to design, construction, testing, operation, and... Withdrawn Standard
495-1986 - Guide for Testing Faulted Circuit IndicatorsDefinitions, service conditions, test procedures, and conditions for faulted circuit indicators for use on power distribution systems are established. Withdrawn Standard
495-2007 - Guide for Testing Faulted Circuit IndicatorsDefinitions, service conditions, test procedures, and test conditions for faulted circuit indicators for use on power distribution systems are... Active Standard
497-2002 - Standard Criteria for Accident Monitoring Instrumentation for Nuclear Power Generating StationsCriteria for variable selection, performance, design, and qualification of accident monitoring instrumentation are established in this standard.... Superseded Standard
497-1981 - Standard Criteria for Accident Monitoring Instrumentation for Nuclear Power Generating StationsThis IEEE standard applies to the design of instrumentation provided for the control room operator to monitor variables required to determine... Withdrawn Standard
497-2002/Cor 1-2007 - Standard Criteria for Accident Monitoring Instrumentation for Nuclear Power Generating Stations - Corrigendum 1: Incorporation of User Feedback through 2005This corrigendum incorporates user feedback by providing editorial and minor technical corrections to IEEE Std 497-2002. The corrigendum also... Superseded Standard
498-1985 - Standard Requirements for the Calibration and Control of Measuring and Test Equipment Used in Nuclear FacilitiesThis standard sets forth the requirements for a calibration program to control and verify the accuracy of measuring and test equipment used to... Superseded Standard
Displaying results 321 - 360 of 1335 - all results