C62.41.2-2002 - Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and less) AC Power CircuitsThe scope of this recommended practice is to characterize the surge environment at locations on AC power circuits described in IEEE Std C62.41.1... Active Standard
C62.42-1987 - Guide for the Application of Gas Tube Arrester Low-Voltage Surge-Protective DevicesThe application guide applies to surge-protective devices used in systems with voltages of 1000 V RMS and 1200 V DC or less. These protective... Superseded Standard
C62.42-1992 - Guide for the Application of Gas Tube and Air Gap Arrester Low-Voltage (Equal to or Less than 1000 V rms or 1200 V dc) Surge Protective DevicesIn this standard, assistance in selecting the most appropriate type of low-voltage surge-protective device (either gas tube or air gap) for a... Superseded Standard
C62.42-2005 - Guide for the Application of Component Surge-Protective Devices for Use in Low-Voltage [Equal to or Less than 1000 V (ac) Or 1200 V (dc)] CircuitsAssistance in selecting the most appropriate type of low-voltage component surge-protective device (gas tube, air gap, metal-oxide varistor, or... Active Standard
C62.43-2005 - Guide for the Application of Surge Protectors Used in Low-Voltage (Equal to or Less than 1000 Vrms or 1200 Vdc) Data, Communications, and Signaling CircuitsThis guide provides assistance in selecting the most appropriate type of surge protector for a particular data, communication, and/or signaling... Active Standard
C62.43-1999 - Guide for the Application of Surge Protectors Used in Low-Voltage (Less Than Or Equal To 1000 Vrms or 1200 Vdc) Data, Communications, and Signaling CircuitsAssistance is provided for the selection of the most appropriate type of low-voltage data, communications, and/or signalling circuit surge... Superseded Standard
C62.45-2002 - Recommended Practice on Surge Testing for Equipment Connected to Low-Voltage (1000 V and less) AC Power CircuitsThe scope of this recommended practice is the performance of surge testing on electrical and electronic equipment connected to low-voltage ac... Active Standard
C62.45-1987 - Guide on Surge Testing for Equipment Connected to Low-Voltage AC Power CircuitsThis document provides guidance on surge testing AC power interfaces of equipment connected to low-voltage circuits that are subject to transient... Superseded Standard
C62.45-1992 - Guide on Surge Testing for Equipment Connected to Low-Voltage AC Power CircuitsGuidance is provided for applying surge testing to ac power interfaces of equipment connected to low-voltage ac power circuits that are subject to... Superseded Standard
C62.47-1992 - Guide on Electrostatic Discharge: Characterization of the ESD EnvironmentThe electromagnetic threat posed to electronic equipment and subassemblies by actual electrostatic discharge (ESD) events from humans and mobile... Withdrawn Standard
C62.48-2005 - Guide on Interactions Between Power System Disturbances and Surge Protective DevicesInformation is provided to users and manufacturers of surge-protective devices (SPIDs) about the interactions that can occur between SPIDs and... Active Standard
C62.48-1995 - Guide on Interactions Between Power System Disturbances and Surge-Protective DevicesIn this IEEE standard information is provided to users and manufacturers of surge-protective devices (SPDs) about the interactions that may occur... Superseded Standard
C62.62-2000 - Standard Test Specifications for Surge Protective Devices for Low Voltage AC Power CircuitsThis standard establishes methods for testing and measuring the performance characteristics for surge-protective devices used in low-voltage AC... Superseded Standard
C62.62-2010 - Standard Test Specifications for Surge-Protective Devices (SPDs) for Use on the Load Side of the Service Equipment in Low Voltage (1000 V and less) AC Power CircuitsSurge-protective devices (SPDs) intended to be installed on the load side of the service equipment connected to 50 Hz or 60 Hz AC power circuits... Active Standard
C62.64-1997 - Standard Specifications for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling CircuitsThis standard applies to surge protectors for application on multiconductor and coaxial, balanced or unbalanced, data, communications and... Superseded Standard
C62.64-2009 - Standard Specifications for Surge Protectors Used in Low-Voltage Data, Communications,and Signaling CircuitsSurge protectors for application on multiconductor and coaxial, balanced or unbalanced, data, communications, and signaling circuits with voltages... Active Standard
C62.72-2007 - Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power CircuitsInformation is provided to specifiers and users of surge-protective devices (SPDs) about the application considerations of SPDs associated with... Active Standard
C62.92-1987 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part 1 - IntroductionSome basic considerations for the selection of neutral grounding parameters that will provide for the control of ground-fault current and... Superseded Standard
C62.92.1-2000 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part 1 - IntroductionThis guide is the introduction to the C62.92 series of five IEEE guides on neutral grounding in three-phase electrical utility systems. It... Active Standard
C62.92.3-1993 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III - Generator Auxiliary SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power... Superseded Standard
C62.92.3-2012 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III -Generator Auxiliary SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power... Active Standard
C62.92.4-1991 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part IV-DistributionIn this standard the neutral grounding of singleand three-phase AC electric utility primary distribution systems with nominal voltages in the... Active Standard
C62.92.5-1992 - Guide for the Application of Neutral Grounding in Electric Utility Systems, Part V - Transmission Systems and Subtransmission SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for a particular AC transmission or subtransmission... Superseded Standard
C62.92.5-2009 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part V-Transmission Systems and Subtransmission SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for a particular ac transmission or subtransmission... Active Standard
C62.92.2-1989 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part II - Grounding of Synchronous Generator SystemsReaffirmed in 2005 General considerations for grounding synchronous generator systems are summarized, focusing on the objectives of generator... Active Standard
C92.2-1987 - American National Power Systems - Alternating-Current Electrical Systems and Equipment Operating at Voltages Above 230 kV Nominal-Preferred Voltage RatingsThe article presents ANSI standard C92.2-1987. This standard supersedes ANSI C92.2-1981, preferred voltage ratings for alternating-current... Superseded Standard
C135.1-1999 - Zinc-Coated Steel Bolts and Nuts for Overhead Line ConstructionThe requirements for inch-based carriage bolts, machine bolts, double-arming bolts, and double-end bolts and nuts, commonly used in overhead line... Active Standard
C135.2-1999 - Threaded Zinc-Coated Ferrous Strand-Eye Anchor Rods and Nuts for Overhead Line ConstructionRequirements for threaded zinc-coated ferrous strand-eye anchor rods and nuts commonly used in overhead power line construction are covered in... Active Standard
C135.3-2001 - Zinc-Coated Ferrous Lag Screws for Overhead Line ConstructionZinc-coated steel lag screws of the fetter drive, gimlet point, and twist drive types commonly used in overhead line construction are covered in... Active Standard
C135.20-1998 - Zinc-Coated Ferrous Insulator Clevises for Overhead Line ConstructionZinc-coated ferrous clevises for spool-type insulators commonly used for supporting or dead-ending conductors in line construction are covered.... Active Standard
C135.61-1997 - the Testing of Overhead Transmission and Distribution Line HardwareRequirements for mechanically testing load-rated line hardware for use on transmission and distribution facilities are described. Items... Active Standard
C135.62-2009 - Zinc-Coated Forged Anchor ShacklesDimensions and strength requirements for anchor shackles used in overhead transmission and distribution line hardware are covered in this standard. Active Standard
C135.63-1998 - Shoulder Live Line Extension Links for Overhead Line ConstructionDimensions and strength requirements for shoulder live line extension links used in overhead transmission and distribution hardware are covered. Active Standard
62539-2007 - IEC 62539 Ed.1 (Std 930 (TM)-2004): Guide for the Statistical Analysis of Electrical Insulation Breakdown DataAbstract: This guide describes, with examples, statistical methods to analyze times to break down and breakdown voltage data obtained from... Active Standard