Standard Icon

Industry Applications Standards

Standard Name
Status Help less all
3-1982 - Recommended Practice in the Selection of Reference Ambient Conditions for Test Measurements of Electrical ApparatusIn general test results and the performance of electrical apparatus are significantly influenced by variations in such parameters as temperature,... Withdrawn Standard
4a-2001 - Amendment to Standard Techniques for High-Voltage TestingThis amendment sets forth a number of clarifications and corrections to IEEE Standard Techniques for High-Voltage Testing. Superseded Standard
11-1980 - Rotating Electric Machinery for Rail and Road VehiclesThis IEEE standard applies to rotating electric machinery which forms part of the propulsion and major auxiliary equipment on internally and... Superseded Standard
11-2000 - Rotating Electric Machinery for Rail and Road VehiclesThis standard applies to rotating electric machinery which forms part of the propulsion and major auxiliary equipment on internally and externally... Active Standard
18-1980 - Shunt Power CapacitorsThis standard applies to capacitors rated 216 V or higher, 5 kVAr or more, and designed for shunt connection to alternating current transmission... Superseded Standard
18-1992 - Shunt Power CapacitorsCapacitors rated 216 V or higher, 2.5 kVAr or more, and designed for shunt connection to alternating-current transmission and distribution systems... Superseded Standard
18-2002 - Shunt Power CapacitorsCapacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection to alternating-current transmission and distribution systems... Superseded Standard
18-2012 - Shunt Power CapacitorsPower capacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection to alternating-current transmission and distribution... Active Standard
32-1972 - Standard Requirements, Terminology, and Test Procedures for Neutral Grounding DevicesThis standard applies to devices used for the purpose of controlling the ground current or the potentials to ground of an alternating current... Active Standard
43-1974 - Recommended Practice for Testing Insulation Resistance of Rotating MachineryThis document describes the recommended procedure for the measurement of insulation resistance of windings of rotating machines rated 1 hp, 1 kW... Superseded Standard
43-2000 - Recommended Practice for Testing Insulation Resistance of Rotating MachineryThis document describes the recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 1... Superseded Standard
43-2013 - Recommended Practice for Testing Insulation Resistance of Electric MachineryThe dc voltage tests procedures for the measurement of the insulation resistance and polarization index of insulated stator, and rotor windings... Active Standard
45-1998 - Recommended Practice for Electric Installations on ShipboardRecommendations for the selection and installation of equipment on merchant vessels with electric apparatus for lighting, signaling, communication... Superseded Standard
45-2002 - Recommended Practice for Electric Installations on ShipboardRecommendations for the design, selection, and installation of equipment on merchant vessels with electrical apparatus for lighting, signaling,... Active Standard
45.2-2011 - Recommended Practice for Electrical Installations on Shipboard -- Controls and AutomationThe recommendations for controls, control applications, control apparatus, and automation on shipboards are established by this document. These... Active Standard
45.7-2012 - Recommended Practice for Electrical Installations on Shipboard -- AC SwitchboardsRecommendations for the design, selection, and installation of switchboards on merchant vessels with electrical apparatus for lighting, signaling,... Active Standard
48-1975 - Standard Test Procedures and Requirements for High-Voltage Alternating-Current Cable TerminationsThis standard encompasses all (with one exception) terminations for alternating-current high-voltage cables having laminated or extruded... Superseded Standard
48-1990 - Standard Test Procedures and Requirements for High-Voltage Alternating-Current Cable TerminationsThis standard covers all indoor and outdoor cable terminations used on alternating-current cables having laminated or extruded insulation rated 2... Superseded Standard
48-1996 - Standard Test Procedures and Requirements for Alternating-Current Cable Terminations 2.5 kV Through 765 kVAll indoor and outdoor cable terminations used on alternating-current cables having laminated or extruded insulation rated 2.5 kV through 765 kV... Superseded Standard
48-2009 - Test Procedures and Requirements for Alternating-Current Cable Terminations Used on Shielded Cables Having Laminated Insulation Rated 2.5 kV through 765 kV or Extruded Insulation Rated 2.5 kV through 500 kVThis standard covers all indoor and outdoor cable terminations used on alternating-current shielded cables having laminated insulation from 2.5 kV... Active Standard
55-1953 - Guide for Temperature Correlation in the Connection of Insulated Wire and Cables to Electronic EquipmentAlthough the standard permissible operating temperatures of various types of equipment are different for one reason or another, this causes little... Withdrawn Standard
56-1977 - Guide for Insulation Maintenance of Large Alternating-Current Rotating Machinery (10,000 kVA and Larger)The purpose of this IEEE guide is to present information necessary to permit an effective evaluation of the insulation systems of large... Withdrawn Standard
58-1978 - Standard Induction Motor Letter SymbolsWithdrawn Standard. Withdrawn Date: Dec 05, 1991. Withdrawn Standard
62-1995 - Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and ReactorsIn this IEEE Standard, diagnostic tests and measurements that are performed in the field on oil-immersed power transformers and regulators are... Superseded Standard
62.2-2004 - Guide for Diagnostic Field Testing of Electric Power Apparatus - Electrical MachineryThis is a guide for determining applicable tests and inspection techniques for various types of large rotating electric machines. It provides... Active Standard
67-1972 - Guide for Operation and Maintenance of Turbine GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators with cylindrical... Superseded Standard
67-1990 - Guide for Operation and Maintenance of Turbine GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators having cylindrical... Superseded Standard
67-2005 - Guide for Operation and Maintenance of Turbine GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators that have... Active Standard
80-1986 - Guide for Safety in AC Substation GroundingThe third edition of this guide represents the first major revision since its first issue in 1961. Major modifications include the redefinition of... Superseded Standard
80-2000 - Guide for Safety in AC Substation GroundingOutdoor ac substations, either conventional or gas-insulated, are covered in this guide. Distribution, transmission, and generating plant... Superseded Standard
80-2013 - Approved Draft Guide for Safety in AC Substation GroundingThis guide is primarily concerned with outdoor AC substatons, either air-insulated or gas-insulated. Distribution, transmission and power plant... Active Standard
81-1983 - Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System Part 1: Normal MeasurementsThe technique of measuring ground resistance and impedance, earth resistivity, potential gradients from currents in the earth, and the prediction... Superseded Standard
81-2012 - Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding SystemPractical test methods and techniques are presented for measuring the electrical characteristics of grounding systems. Topics addressed include... Active Standard
81.2-1991 - Guide for Measurement of Impedance and Safety Characteristics of Large, Extended or Interconnected Grounding SystemsThe purpose of this guide is to present practical instrumentation methods that may be used for the measurement of impedance to remote earth, step... Withdrawn Standard
82-1994 - Standard Test Procedure for Impulse Voltage Tests on Insulated ConductorsA test procedure for impulse testing of insulated conductors (cables) and cables with accessories installed (cable systems) is provided in this... Withdrawn Standard
82-2002 - Standard Test Procedure for Impulse Voltage Tests on Insulated ConductorsA test procedure for the impulse testing of insulated conductors (cables) and cables with accessories installed (cable systems) is provided in... Active Standard
83-1963 - Test Procedure for Radial Power Factor Tests on Insulating Tapes in Paper-Insulated Power CableA test procedure for determining the radial power factor of insulating tapes in power cable is presented. Three-terminal type electrodes are... Withdrawn Standard
85-1973 - Test Procedure for Airborne Sound Measurements on Rotating Electric MachineryThis test procedure defines approved methods for conducting tests and reporting results to effect the uniform determination of rotating electric... Withdrawn Standard
86-1987 - Recommended Practice: Definitions of Basic Per-Unit Quantities for AC Rotating MachinesThe proper selection of base values is fundamental to the usefulness of a per-unit system. Although per-unit quantities have been used for many... Withdrawn Standard
94-1991 - Recommended Definitions of Terms for Automatic Generation Control on Electric Power SystemsThe need for standard terminology in the field of automatic generation control (AGC) became apparent when it was noted that authors of technical... Withdrawn Standard
95-1977 - Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Direct VoltageSuperseded by 95-2002. Recommendations are made to aid in the selection of metric units, so as to promote uniformity in the use of metric units... Superseded Standard
95-2002 - Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct VoltageThis recommended practice provides information on the use of high direct voltage for proof tests and for periodic diagnostic tests on the... Active Standard
96-1969 - General Principles for Rating Electric Apparatus for Short-Term, Intermittent, or Varying DutyThis standard establishes general principles for rating electric apparatus for short-time, intermittent, or varying duty. The four methods used... Withdrawn Standard
97-1969 - Recommended Practice for Specifying Service Conditions in Electrical StandardsThis document has been prepared as a guide for technical committees to use when standards are being prepared or revised, with the object of... Withdrawn Standard
98-1984 - the Preparation of Test Procedures for the Thermal Evaluation of Solid Electrical Insulating MaterialsPrinciples are given for the development of test procedures to evaluate the thermal endurance of solid electrical insulating materials and simple... Superseded Standard
98-2002 - the Preparation of Test Procedures for the Thermal Evaluation of Solid Electrical Insulating MaterialsPrinciples for the development of test procedures to evaluate the thermal endurance of solid electrical insulating materials in air are given in... Active Standard
99-1980 - Recommended Practice for the Preparation of Test Procedures for the Thermal Evaluation of Insulation Systems for Electric EquipmentThe purpose of this recommended practice is to provide a general form for the preparation of test procedures and to suggest the points to be... Superseded Standard
99-2007 - Recommended Practice for the Preparation of Test Procedures for the Thermal Evaluation of Insulation Systems for Electrical EquipmentA general form is provided for the preparation of test procedures. Points to be considered by technical committees in the preparation of specific... Active Standard
100-1992 - The New Standards Dictionary of Electrical and Electronics TermsOver 30,000 terms and definitions that have been standardized by IEEE are included. Over 10,000 new and revised terms have been added since 1988.... Superseded Standard
112-1984 - Standard Test Procedure for Polyphase Induction Motors and GeneratorsCovers instructions for conducting and reporting the more generally applicable and acceptable tests to determine the performance characteristics... Superseded Standard
112-1991 - Standard Test Procedure for Polyphase Induction Motors and GeneratorsInstructions are given for conducting and reporting the more generally applicable and acceptable tests to determine the performance... Superseded Standard
112-1996 - Standard Test Procedure for Polyphase Induction Motors and GeneratorsInstructions are given for conducting and reporting the more generally applicable and acceptable tests to determine the performance... Superseded Standard
112-2004 - Standard Test Procedure for Polyphase Induction Motors and GeneratorsInstructions for conducting, reporting the more generally applicable, acceptable tests of polyphase induction motors, generators are covered. Active Standard
113-1985 - Guide: Test Procedures for Direct-Current MachinesRecommendations are made for conducting and reporting generally acceptable tests to determine the performance characteristics of conventional DC... Withdrawn Standard
114-1982 - Standard Test Procedure for Single-Phase Induction MotorsThis standard covers instructions for conducting and reporting the more generally applicable and acceptable tests to determine the performance... Withdrawn Standard
114-2001 - Standard Test Procedure for Single-Phase Induction MotorsInstructions are given for conducting and reporting the more generally applicable and acceptable tests to determine the performance... Withdrawn Standard
114-2010 - Standard Test Procedure for Single-Phase Induction MotorsInstructions for conducting and reporting the more generally applicable and acceptable test to determine the performance characteristics of single... Active Standard
115-1983 - Guide: Test Procedures for Synchronous MachinesContains instructions for conducting the more generally applicable and accepted tests to determine the performance characteristics of synchronous... Superseded Standard
115-1995 - (Superseded) Guide: Test Procedures for Synchronous Machines Part I--Acceptance and Performance Testing Part II-Test Procedures and Parameter Determination for Dynamic AnalysisInstructions for conducting the more generally applicable and accepted tests to determine the performance characteristics of synchronous machines... Superseded Standard
115-2009 - Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic AnalysisInstructions for conducting generally applicable and accepted tests to determine the performance characteristics of synchronous machines are... Active Standard
115A-1987 - Standard Procedures for Obtaining Synchronous Machine Parameters by Standstill Frequency Response TestingA method is described for obtaining synchronous machine parameters in the form of reactances and time constants. A new approach has demonstrated... Superseded Standard
116-1975 - Standard Test Procedures for Carbon BrushesIt is the purpose of this standard to provide a procedure for determining certain operating characteristics of carbon, carbon-graphite,... Withdrawn Standard
117-1974 - Standard Test Procedure for Evaluation of Systems of Insulating Materials for Random-Wound AC Electric MachineryUseful methods for the evaluation of systems of insulation for random-wound stators of rotating electric machines are given. The chief purpose is... Withdrawn Standard
118-1978 - Standard Test Code for Resistance MeasurementThe purpose of this code is to present methods of measuring electrical resistance which are commonly used to determine the characteristics of... Withdrawn Standard
119-1974 - Recommended Practice for General Principles of Temperature Measurement as Applied to Electrical ApparatusThe purpose of this document is to provide guidelines for the application of temperature-measurement techniques in measuring the operating... Withdrawn Standard
120-1955 - Elec Msmts/Power CircuitsSuperseded by IEEE 120-1989 The methods given here include measurements, as made with either indicating or integrating instruments, of power,... Superseded Standard
120-1989 - Master Test Guide for Electrical Measurements in Power CircuitsThis guide gives instructions for those measurements of electrical quantities that are commonly needed in determining the performance... Active Standard
122-1985 - Recommended Practice for Functional Performance Characteristics of Control Systems for Steam Turbine-Generator UnitsThe object of this IEEE recommended practice is to recommend minimum functional and performance characteristics related to speed/load control... Superseded Standard
122-1991 - Recommended Practice for Functional and Performance Characteristics of Control Systems for Steam Turbine-Generator UnitsMinimum functional and performance characteristics related to speed/load-control systems for steam turbine-generator units that may be... Withdrawn Standard
139-1988 - Recommended Practice for the Measurement of Radio Frequency Emission from Industrial, Scientific, and Medical (ISM) Equipment Installed on User's PremisesDescribes equipment inspection and radio frequency (RF) electromagnetic field measurement procedures for evaluation of RF industrial, scientific,... Active Standard
141-1986 - Recommended Practice for Electric Power Distribution for Industrial Plants (IEEE Red Book)A thorough analysis of basic electrical-systems considerations is presented. Guidance is provided in design, construction, and continuity of an... Superseded Standard
141-1993 - Recommended Practice for Electric Power Distribution for Industrial PlantsA thorough analysis of basic electrical-systems considerations is presented. Guidance is provided in design, construction, and continuity of an... Active Standard
142-1982 - Recommended Practice for Grounding of Industrial and Commercial Power Systems (IEEE Green Book)The problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered... Superseded Standard
142-1991 - Recommended Practice for Grounding of Industrial and Commercial Power SystemsThe problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered... Superseded Standard
142-2007 - Recommended Practice for Grounding of Industrial and Commercial Power SystemsThe problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered... Active Standard
148-1959 - Waveguide and Waveguide Component MeasurementsThis standard is concerned with measurements of the quantities which characterize a waveguide or waveguide component and the associated... Withdrawn Standard
152-1991 - Audio Program Level MeasurementTwo audio program level measuring devices, the peak-program meter and the standard volume indicator, are described. The peak-program meter is... Withdrawn Standard
176-1987 - Standard on PiezoelectricityThis standard on piezoelectricity contains many equations based upon the analysis of vibrations in piezoelectric materials having simple... Withdrawn Standard
177-1966 - Standard Definitions and Methods of Measurements for Piezoelectric VibratorsAn introductory review of the equivalent electric circuit of a piezoelectric vibrator and its parameters is followed by a discussion of the... Withdrawn Standard
180-1986 - Standard Definitions of Primary Ferroelectric TermsCompared to some of the older areas of specialization found within the IEEE organization, ferroelectrics is a relatively new field. The first... Withdrawn Standard
181-1977 - Standard on Pulse Measurement and Analysis by Objective TechniquesThis standard provides definitions and descriptions of the techniques and procedures for time domain pulse measurements. The definitions and... Withdrawn Standard
181-2003 - Standard on Transitions, Pulses, and Related WaveformsThis standard presents approximately 100 terms, and their definitions, for accurately and precisely describing the waveforms of pulse signals and... Superseded Standard
181-2011 - Transitions, Pulses, and Related WaveformsApproximately 100 terms and their definitions, for accurately and precisely describing the waveforms of pulse signals and the process of measuring... Active Standard
187-1990 - Standard on Radio Receivers: Open Field Method of Measurement of Spurious Radiation from FM and Television Broadcast ReceiversSpurious radiations from the local oscillator of modern broadcast radio receivers of the superheterodyne type are possible sources of interference... Superseded Standard
187-2003 - Standard Measurement Methods of Emissions from FM and Television Broadcast Receivers in the Frequency Range of 9kHz to 40GHzIEEE Std 187-2003 is the standard for measurement methods of emissions from FM and television broadcast receivers in the frequency range of 9 kHz... Active Standard
205-1958 - Standards on Television: Measurement of Luminance Signal LevelsDescribes methods of measuring the significant amplitude levels of a monochrome or color television signal, either composite or noncomposite. The... Withdrawn Standard
205-2001 - Standard on Television: Measurement of Luminance Signal LevelsA method of measuring the amplitude levels of an SMPTE 170M-1994; NTSC color or monochrome television video signal is described. It is concerned... Withdrawn Standard
206-1960 - Standards on Television: Measurement of Differential Gain and Differential PhaseDescribes a method for measuring differential gain and differential phase in equipment transmitting either monochrome or color television signals.... Withdrawn Standard
208-1960 - Standards on Video Techniques: Measurement of Resolution of Camera Systems, 1961This standard is a revision of Part II of 50 IRE23.S1, and replaces it in all respects. One of the major characteristics of a television system... Withdrawn Standard
208-1995 - Standard on Video Techniques: Measurement of Resolution of Camera Systems, 1993 TechniquesThe methods for measuring the resolution of camera systems are described. The primary application is for users and manufacturers to quantify the... Active Standard
213-1987 - Standard Procedure for Measuring Conducted Emissions in the Range of 300 kHz to 25 MHz from Television and FM Broadcast Receivers to Power LinesTelevision and FM broadcast receivers are frequently potential sources of interference to other television and FM broadcast receivers and to... Withdrawn Standard
241-1990 - Recommended Practice for Electric Power Systems in Commercial BuildingsA guide and general reference on electrical design for commercial buildings is provided. It covers load characteristics; voltage considerations;... Active Standard
242-1986 - Recommended Practice for Protection and Coordination of Industrial and Commercial Power SystemsSuperseded Standard. This publication presents a step-by-step, simplified, yet comprehensive, form the principles of system protection and the... Superseded Standard
242-2001 - Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)The principles of system protection and the proper selection, application, and coordination of components that may be required to protect... Active Standard
251-1984 - Standard Test Procedures for Direct-Current Tachometer GeneratorsThis test procedure covers instructions for conducting and reporting the more generally applicable and acceptable tests to determine the... Withdrawn Standard
252-1977 - Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic GapThis test procedure covers instructions for conducting and reporting the more generally applicable and acceptable tests to determine the... Superseded Standard
252-1995 - Standard Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic GapIn this IEEE Standard instructions for conducting and reporting the more generally applicable and acceptable tests to determine the performance... Active Standard
260-1978 - Standard Letter Symbols for Units of Measurement (SI Units, Customary Inch-Pound Units, and Certain Other Units)Close cooperation of committees of the International Electrotechnical Commission, the International Organization for Standardization, and the SUN... Superseded Standard
260.1-1993 - American National Standard Letter Symbols for Units of Measurement (SI Units, Customary Inch-Pound Units, and Certain Other Units)General principles of letter symbol standardization are discussed. Symbols are given for general use and for use with limited character sets. The... Superseded Standard
260.1-2004 - Standard Letter Symbols for Units of Measurement (SI Customary Inch-Pound Units, and Certain Other Units)Letter symbols for units of measurement are covered in this standard. It does not include abbreviations for technical terms, nor does it cover... Active Standard
269-1992 - Standard Methods for Measuring Transmission Performance of Analog and Digital Telephone SetsPractical methods for measuring the transmission characteristics of both digital and conventional two-wire analog telephone sets by means of... Superseded Standard
269-2002 - Standard Methods for Measuring Transmission Performance of Analog and Digital Telephone Sets, Handsets, and HeadsetsPractical methods for making laboratory measurements of electroacoustic characteristics of analog and digital telephones, handsets, and headsets... Superseded Standard
269-2010 - Standard Methods for Measuring Transmission Performance of Analog and Digital Telephone Sets, Handsets, and HeadsetsPractical methods for making laboratory measurements of electroacoustic characteristics of analog and digital telephones, handsets and headsets.... Active Standard
269a-2007 - Standard Methods for Measuring Transmission Performance of Analog and Digital Telephone Sets, Handsets, and Headsets Amendment 1This document amends IEEE Std 269-2002. It covers the areas of: analog telephones; digital telephones; electroacoustic measurements on telephones;... Superseded Standard
269a-2012 - Standard Methods for Measuring Transmission Performance of Analog and Digital Telephone Sets, Handsets, and Headsets--Amendment 1Practical methods for making laboratory measurements of electroacoustic characteristics of analog and digital telephones, handsets, and headsets... Active Standard
275-1992 - Recommended Practice for Thermal Evaluation of Insulation Systems for Alternating-Current Electric Machinery Employing Form-Wound Preinsulated Stator Coils for Machines Rated 6900 V and BelowIn this standard a test procedure for comparing two or more insulation systems in accordance with their expected life at rated temperature is... Withdrawn Standard
277-1994 - Recommended Practice for Cement Plant Power DistributionElectrical distribution systems in cement plants that would result in satisfactory equipment utilization, reliability, performance, safety, and... Superseded Standard
277-2007 - Recommended Practice for Cement Plant Power DistributionThis document has been developed as a recommended practice for electrical distribution systems in cement plants that would result in satisfactory... Active Standard
284-1968 - Standards Report on State-of-the-Art of Measuring Field Strength, Continuous Wave, SinusoidalThis document is a Report on the state-of-the-art of measuring field strength of radio-frequency electromagnetic waves, with respect to available... Withdrawn Standard
286-1975 - Recommended Practice for Measurement of Power-Factor Tip-Up of Rotating Machinery Stator Coil InsulationThe purpose of this recommended practice is to describe the power-factor tip-up of coil insulation and to establish preferred procedures for its... Withdrawn Standard
286-2000 - Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil InsulationThe power factor tip-up testing of stator coils and bars for use in large electric machinery is covered in this recommended practice. Active Standard
290-1980 - Electric Couplings; Part I - General, Rating, Performance Characteristics; Part II - Test ProceduresElectric couplings are widely used to transmit mechanical torque from one rotating member to another. They are distinguished from mechanical... Withdrawn Standard
291-1969 - Standards Report on Measuring Field Strength in Radio Wave PropagationMost measurements with which radio wave propagation is concerned involve the measurement of field strength. Thus, the determination of power... Superseded Standard
291-1991 - Standard Methods for Measuring Electromagnetic Field Strength of Sinusoidal Continuous Waves, 30 Hz to 30 GHzTwo standard methods for field-strength measurement are described. The standard-antenna method consists of measuring the received power or open... Withdrawn Standard
299-1991 - Measuring the Effectiveness of Electromagnetic Shielding EnclosuresUniform measurement procedures and techniques are provided for determining the effectiveness of room-sized, high-performance electromagnetic... Superseded Standard
299-1997 - Standard Method for Measuring the Effectiveness of Electromagnetic Shielding EnclosuresUniform measurement procedures and techniques are provided for determining the effectiveness of electromagnetic shielding enclosures at... Superseded Standard
299-2006 - Standard Method for Measuring the Effectiveness of Electromagnetic Shielding EnclosuresUniform measurement procedures and techniques are provided for determining the effectiveness of electromagnetic shielding enclosures at... Active Standard
299.1-2013 - Standard Method for Measuring the Shielding Effectiveness of Enclosures and Boxes Having all Dimensions between 0.1 m and 2 mThis standard provides uniform measurement procedures for determining the shielding effectiveness of electromagnetic (EM) shielding for a variety... Active Standard
302-1969 - Standard Methods for Measuring Electromagnetic Field Strength for Frequencies Below 1000 MHz in Radio Wave PropagationStandard methods for the measurement of electromagnetic field strength in radiowave propagation are described in detail. These are for frequencies... Withdrawn Standard
303-1991 - Recommended Practice for Auxilary Devices for Motors in Class I, Groups A,B,C, and D, Division 2 LocationsInstallation procedures and wiring methods and materials are recommended in this IEEE standard. Termination housings, motor surge protection, and... Superseded Standard
303-2004 - Recommended Practice for Auxiliary Devices for Rotating Electrical Machines in Class I, Division 2 and Zone 2 LocationsThis recommended practice applies to the application and installation procedures of auxiliary devices in or on electric rotating machines that are... Active Standard
304-1977 - Test Procedure for Evaluation and Classification of Insulation Systems for Direct-Current MachinesThis test procedure has been prepared to serve as a useful guide for the evaluation of insulation systems for direct-current machines and to... Withdrawn Standard
314-1971 - Standards Report on State of the Art of Measuring Unbalanced Transmission-Line ImpedanceThis document is concerned with reporting the state of the art of measuring impedance in distributed parameter coaxial waveguide systems,... Withdrawn Standard
315-1975 - Graphic Symbols for Electrical and Electronics Diagrams (Including Reference Designation Letters)A list of graphic symbols and class designation letters for use on electrical and electronics diagrams is provided. All of the symbols are... Active Standard
315A-1986 - Supplement to Graphic Symbols for Electrical and Electronics DiagramsGraphic symbols and information needed for use on electrical and electronic diagrams, which are internationally approved, are presented. Active Standard
319-1971 - Standard on Magnetostrictive Materials: Piezomagnetic NomenclatureThe purpose of this Standard is to make possible the comparison of the relative merits of magnetostrictive, electromagnetic, piezoelectric, and... Superseded Standard
319-1990 - Standard on Magnetostrictive Materials: Piezomagnetic NomenclatureThis standard serves to aid the comparison of the relative merits of magnetostrictive, electromagnetic, piezoelectric, and electrostrictive... Withdrawn Standard
333-1980 - Electrical Installation of Packaging Machinery and Associated EquipmentThe purpose of this standard is to provide guidelines for the proper application of electrical equipment to packaging machinery. These guidelines... Withdrawn Standard
336-1985 - Standard Installation, Inspection and Testing Requirements for Power, Instrumentation, and Control Equipment at Nuclear FacilitiesThis standard sets forth the requirements for installation, inspection, and testing of power, instrumentation, and control equipment and systems... Superseded Standard
336-2005 - Guide for Installation, Inspection, and Testing for Class 1E Power, Instrumentation, and Control Equipment at Nuclear FacilitiesThis guide provides considerations for the pre-installation, installation, inspection, and testing of Class 1E power, instrumentation, and control... Superseded Standard
336-2010 - Recommended Practice for Installation, Inspection, and Testing for Class 1E Power, Instrumentation, and Control Equipment at Nuclear FacilitiesConsiderations for the pre-installation, installation, inspection, and testing of Class 1E power, instrumentation, and control equipment and... Active Standard
356-1974 - Guide for Radio Methods for Measuring Earth ConductivityThe guide presents a survey of radio techniques for measuring the electrical conductivity of the Earth. The results are applicable to the design... Withdrawn Standard
356-2001 - Guide for Measurements of Electromagnetic Properties of Earth MediaThe electromagnetic properties of the earth play an important role in the design and implementation of radio communications systems, geophysical... Superseded Standard
356-2010 - Guide for Measurements of Electromagnetic Properties of Earth MediaMeasurements of the electrical properties of naturally occurring solids are covered in the scope of this project. Not covered are methods that... Active Standard
367-1987 - Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power FaultWire-line telecommunication facilities serving electric power stations often require that extraordinary protection measures be taken to protect... Superseded Standard
367-1996 - Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power FaultGuidance for the calculation of power station ground potential rise (GPR) and longitudinal induction (LI) voltages is provided, as well as... Superseded Standard
367-2012 - Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power FaultGuidance for the calculation of power station ground potential rise (GPR) and longitudinal induction (LI) voltages is provided, as well as... Active Standard
376-1975 - the Measurement of Impulse Strength and Impulse BandwidthFor many purposes in radio interference and electromagnetic compatibility work, it has become convenient to measure broadband emission in terms of... Withdrawn Standard
377-1980 - Recommended Practice for Measurement of Spurious Emission from Land-Mobile Communication TransmittersThis recommended practice covers definitions of terms, controlled test conditions, test apparatus, test methods and data presentation, all of... Active Standard
378-1986 - Standard on Network Analyzers (100 kHz to 18 GHz)This standard was written for users and manufacturers of automatic network analyzers. The purpose of the standard is to provide common terminology... Withdrawn Standard
386-1985 - Separable Insulated Connector Systems for Power Distribution Systems Above 600 VThis IEEE standard establishes definitions, service conditions, ratings, interchangeable construction features and tests for load-break and dead... Superseded Standard
386-1995 - Separable Insulated Connector Systems for Power Distribution Systems above 600 VIn this IEEE Standard, definitions, service conditions, ratings, interchangeable construction features, and tests are established for load-break... Superseded Standard
386-2006 - Separable Insulated Connector Systems for Power Distribution Systems above 600 VDefinitions, service conditions, ratings, interchangeable construction features, and tests are established for loadbreak and deadbreak separable... Active Standard
387-1984 - Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating StationsThe criteria for the application and testing of diesel-generator units as Class 1E standby power supplies in nuclear power generating stations is... Withdrawn Standard
387-1995 - Standard Criteria for Diesel-Generator Units Applied as Standby Power Supplies for Nuclear Power Generating StationsThe criteria for the application and testing of diesel-generator units as Class 1E standby power supplies in nuclear power generating stations is... Active Standard
393-1977 - Test Procedures for Magnetic CoresMost of the test methods described include specific parameter ranges, instrument accuracies, core sizes, etc, and may be used in the specification... Superseded Standard
393-1991 - Test Procedures for Magnetic CoresTest methods useful in the design, analysis, and operation of magnetic cores in many types of applications are presented. Tests for specifying and... Active Standard
399-1980 - Recommended Practice for Power System Analysis (IEEE Brown Book)Superseded by 399-1990. This recommended practice is a reference source for engineers involved in industrial and commercial power systems analysis... Superseded Standard
399-1990 - Recommended Practice for Industrial and Commercial Power System AnalysisSuperseded by 399-1997. This recommended practice is a reference source for engineers involved in industrial and commercial power systems analysis... Superseded Standard
399-1997 - Recommended Practice for Industrial and Commercial Power Systems Analysis (Brown Book)This Recommended Practice is a reference source for engineers involved in industrial and commercial power systems analysis. It contains a thorough... Active Standard
400-1980 - Guide for Making High-Direct-Voltage Tests on Power Cable Systems in the FieldThe purpose of this guide is: to provide uniform procedures for performing high-direct-voltage acceptance tests and maintenance tests on power... Superseded Standard
400-1991 - Guide for Making High-Direct-Voltage Tests on Power Cable Systems in the FieldProcedures and recommended test voltage values for acceptance and maintenance high-direct-voltage testing of shielded power cable systems are set... Superseded Standard
400-2001 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable SystemsThis guide lists the various field test methods that are currently available or under development with guidance on HOW to perform each test. The... Superseded Standard
400-2012 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and AboveVarious field test methods that are currently available or under development are listed in this guide. The guide covers shielded, insulated power... Active Standard
400.1-2007 - Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current VoltageThe recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power... Active Standard
400.2-2004 - Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)This guide describes very low frequency (VLF) withstand and diagnostic tests and the measurements that are performed in the field on shielded... Superseded Standard
400.2-2013 - Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded... Active Standard
400.3-2006 - Guide for Partial Discharge Testing of Shielded Power Cable Systems in a Field EnvironmentThis guide covers the diagnostic testing of new or service-aged installed shielded power cable systems, which include cable, joints, and... Active Standard
402-1974 - Guide for Measuring Resistivity of Cable-Insulation Materials at High Direct Voltages1/92 memo from S. Vogel - Reaff in progress. Submittal expected June 1992 Withdrawn Standard
404-1986 - Cable Joints for Use with Extruded Dielectric Cable Rated 5000 V through 46 000 V and Cable Joints for Use with Laminated Dielectric Cable Rated 2500 V Through 500 000 VTo assure that the performance of the cable joint will equal the performance of the cable it joins electrical ratings and test requirements are... Superseded Standard
404-1993 - Cable Joints for Use With Extruded Dielectric Cable Rated 5000-138 000 V and Cable Joints for Use With Laminated Dielectric Cable Rated 2500-500 000 VThis standard establishes electrical ratings and test requirements for cable joints for use with extruded dielectric shielded cable rated in... Superseded Standard
404-2000 - Extruded and Laminated Dielectric Shielded Cable Joints Rated 2500-500 000VThis standard establishes electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable... Superseded Standard
404-2006 - Extruded and Laminated Dielectric Shielded Cable Joints Rated 2 500v to 500 000vElectrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage... Superseded Standard
404-2012 - Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kVElectrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage... Active Standard
421.3-1998 - High-Potential Test Requirements for Excitation Systems for Synchronous MachinesHigh-potential test voltages for excitation systems used with synchronous machines are established. Test voltages are established based on whether... Active Standard
421.5-1992 - Recommended Practice for Excitation System Models for Power System Stability StudiesExcitation system models suitable for use in large scale power system stability studies are presented. With these models, most of the excitation... Superseded Standard
421.5-2005 - Recommended Practice for Excitation System Models for Power System Stability StudiesExcitation system models suitable for use in large-scale system stability studies are presented. Important limiters and supplementary controls are... Active Standard
428-1981 - Standard Definitions and Requirements for Thyristor AC Power ControllersThese recommendations apply to thyristor AC power controllers that are low voltage, power electronic, industrial class equipment for the control... Withdrawn Standard
429-1994 - Recommended Practice for Thermal Evaluation of Sealed Insulation Systems for AC Electric Machinery Employing Form-Wound Preinsulated Stator Coils for Machines Rated 6900 V and BelowIn this IEEE standard a test procedure for comparing two or more sealed insulation systems in accordance with their expected life at rated... Withdrawn Standard
430-1986 - Standard Procedures for the Measurement of Radio Noise from Overhead Power Lines and SubstationsThe primary purpose of this standard is to establish uniform procedures for the measurement of radio noise generated by corona from overhead power... Withdrawn Standard
432-1976 - Guide for Insulation Maintenance for Rotating Electrical Machinery (5 hp to less than 10 000 hp)This insulation maintenance guide is intended to apply in general to industrial air-cooled rotating electrical machines rated from 5 hp to 10000... Superseded Standard
432-1992 - Guide for Insulation Maintenance for Rotating Electric Machinery (5 hp to less than 10 000 hp)In this standard, information necessary to permit an effective evaluation of the insulation systems of medium and small rotating electric machines... Withdrawn Standard
433-1974 - Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low FrequencyThis document provides a uniform method of VLF testing in order to obtain consistent results, accumulate meaningful experience, and lead to... Withdrawn Standard
433-2009 - Recommended Practice for Insulation Testing™ of AC Electric Machinery with High Voltage at Very Low FrequencyThis recommended practice describes very low frequency withstand and diagnostic tests that are performed on the stator windings of ac electric... Active Standard
434-1973 - Guide for Functional Evaluation of Insulation Systems for Large High-Voltage MachinesThe purpose of this guide is to describe classification test methods which may be used to compare insulation systems in use, or proposed for use,... Superseded Standard
434-2006 - Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and AboveA procedure that may be used to evaluate and compare insulation systems used, or proposed for use, in large ac electric machines is described in... Active Standard
436-1977 - Guide for Making Corona (Partial Discharge) Measurements on Electronics TransformersThis guide covers the detection of corona and the measurement of corona magnitude in electronics transformers. Test conditions, terminology, test... Superseded Standard
436-1991 - Guide for Making Corona (Partial Discharge) Measurements on Electronics TransformersA uniform procedure for making corona (partial discharge) measurements by electrical means on electronic transformers is presented. Methods of... Active Standard
442-1981 - Guide for Soil Thermal Resistivity MeasurementsThis guide covers the measurement of soil thermal resistivity. A thorough knowledge of the thermal properties of a soil will enable the user to... Active Standard
444-1973 - Standard Practices and Requirements for Thyristor Converters for Motor Drives Part 1- Converters for DC Motor Armature SuppliesThis standard applies to all types of line-commutated semiconductor power converters, employing monocrystalline semiconductor thyristors or diodes... Withdrawn Standard
446-1987 - Recommended Practice for Emergency and Standby Power Systems for Industrial and Commerical ApplicationsRecommended engineering principles, practices, and guidelines for the selection and application of emergency and standby power systems are... Superseded Standard
446-1995 - Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial ApplicationsThis Recommended Practice addresses the uses, power sources, design, and maintenance of emergency and standby power systems. Chapter 3 is a... Active Standard
449-1990 - Ferroresonant Voltage RegulatorsThis standard pertains to ferroresonant voltage regulators that operate at relatively constant frequencies and provide substantially constant... Withdrawn Standard
449-1998 - Ferroresonant Voltage RegulatorsFerroresonant transformers used as regulators in electronic power supplies and in other equipment are covered. Guides to application and test... Active Standard
450-1972 - Recommended Practice for Maintenance, Testing, and Replacement of Large Stationary Type Power Plant and Substation Lead Storage BatteriesProper maintenance will prolong the life of a battery and will aid in assuring that it is capable of supplying its design power requirements. A... Superseded Standard
450-1975 - EEE Recommended Practice for Maintenance, Testing, and Replacement of Large Lead Storage Batteries for Generating Stations and SubstationsLarge stationary lead storage batteries play an ever increasing role in substation and generating station control systems and in providing the... Superseded Standard
450-1987 - Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and SubstationsThis recommended practice is limited to providing recommended practices of maintenance, test schedules, and testing procedures than can be used to... Superseded Standard
450-1995 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-2002 - Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-2010 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Active Standard
455-1985 - Standard Test Procedure for Measuring Longitudinal Balance of Telephone Equipment Operating in the Voice BandThe purpose of this standard is threefold: to define the basic requirements of a test circuit which can be used to measure longitudinal balance.... Withdrawn Standard
460-1988 - Electrical Measuring Transducer for Converting AC Electrical Quantities into DC Electrical QuantitiesThis standard applies to measuring transducers used for converting AC electrical quantities such as current, voltage, power (active or reactive),... Withdrawn Standard
463-1977 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesThis standard covers means of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones.... Superseded Standard
463-1993 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans of safeguarding personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided. Included... Withdrawn Standard
463-2006 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans for improved safeguarding of personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided... Superseded Standard
463-2013 - Electrical Safety Practices in Electrolytic Cell Line Working ZonesMeans for improved safeguarding of personnel while operating or maintaining equipment located in electrolytic cell line working zones are provided... Active Standard
475-2000 - Standard Measurement Procedure for Field Disturbance Sensors 300 MHz to 40 GHzTest procedures for microwave field disturbance sensors to measure radio frequency (RF) radiated field strength of the fundamental frequency,... Active Standard
484-1987 - Recommended Practice for Installation Design and Installation of Large Lead Storage Batteries for Generating Stations and SubstationsProvides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly and... Superseded Standard
484-1996 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary ApplicationsIn this IEEE Standard recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
484-2002 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary ApplicationsRecommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of... Active Standard
485-1983 - Recommended Practice for Sizing Large Lead Storage Batteries for Generating Stations and SubstationsMethods for defining the dc load in a generating station or a substation and for sizing a lead storage battery to supply that load are described.... Superseded Standard
485-1997 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary ApplicationsMethods for defining the DC load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float... Superseded Standard
485-2010 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary ApplicationsMethods for defining the direct current (dc) load and for sizing a lead-acid battery to supply that load for stationary battery applications in... Active Standard
487-1980 - Guide for the Protection of Wire-Line Communication Facilities Serving Electric Power StationsWire-line communication facilities serving electric power stations often require special high-voltage protection against the effects of fault... Superseded Standard
487-1992 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Power StationsWorkable methods for protecting wire-line communication circuits entering power stations are presented. This standard covers: the electric power... Superseded Standard
487-2000 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply LocationsWorkable methods for protecting wire-line communication circuits entering electric supply locations are presented. This document covers: the... Superseded Standard
487-2007 - Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply LocationsWorkable methods for protecting wire-line communication circuits entering electric supply locations are presented. This document covers: the... Active Standard
492-1974 - Guide for Operation and Maintenance of Hydro-GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of hydro-generators and generator/motors (pump/turbines),... Withdrawn Standard
492-1999 - Guide for Operation and Maintenance of Hydro-GeneratorsGeneral recommendations for the operation, loading and maintenance of synchronous hydroelectric generators and generator/motors are covered. This... Active Standard
493-1980 - Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (IEEE Gold Book)Superseded. The fundamentals of reliability analysis as it applies to the planning and design of industrial and commercial electric power... Superseded Standard
493-1990 - Recommended Practice for the Design of Reliable Industrial and Commercial Power SystemsThe fundamentals of reliability analysis as it applies to the planning and design of industrial and commercial electric power distribution systems... Superseded Standard
493-1997 - Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (Gold Book)The fundamentals of reliability analysis as it applies to the planning and design of industrial and commercial electric power distribution systems... Superseded Standard
493-2007 - Recommended Practice for the Design of Reliable Industrial and Commercial Power SystemsThe objective of this book is to present the fundamentals of reliability analysis applied to the planning and design of industrial and commercial... Active Standard
495-1986 - Guide for Testing Faulted Circuit IndicatorsDefinitions, service conditions, test procedures, and conditions for faulted circuit indicators for use on power distribution systems are established. Withdrawn Standard
495-2007 - Guide for Testing Faulted Circuit IndicatorsDefinitions, service conditions, test procedures, and test conditions for faulted circuit indicators for use on power distribution systems are... Active Standard
498-1985 - Standard Requirements for the Calibration and Control of Measuring and Test Equipment Used in Nuclear FacilitiesThis standard sets forth the requirements for a calibration program to control and verify the accuracy of measuring and test equipment used to... Superseded Standard
498-1990 - Standard Requirements for the Calibration and Control of Measuring and Test Equipment Used in Nuclear FacilitiesThe standard sets forth the requirements for a calibration program to control and verify the accuracy of measuring and test equipment used to... Withdrawn Standard
499-1989 - Recommended Practice for Cement Plant Electric Drives and Related Electrical EquipmentA recommended practice for electric drives and related electrical equipment for installation in the cement industry is set forth. The... Superseded Standard
499-1997 - Recommended Practice for Cement Plant Electric Drives and Related Electrical EquipmentAll electric drives, including motors and control wiring associated with machinery or equipment commonly used in the manufacturing areas of cement... Active Standard
500-1984 - Guide To The Collection And Presentation Of Electrical, Electronic, Sensing Component, And Mechanical Equipment Reliability Data for Nuclear-Power Generating StationsA method of collecting and presenting reliability data for use in nuclear power generating station reliability calculations is established. It... Withdrawn Standard
511-1979 - Standard on Video Signal Transmission Measurement of Linear Waveform DistortionThe standard describes methods for measuring the linear waveform distortions of TV video signals, that is, distortions which are caused by... Withdrawn Standard
515-1989 - Recommended Practice for the Testing, Design, Installation, and Maintenance of Electrical Resistance Heat Tracing for Industrial ApplicationsThis recommended practice provides recommendations for the testing, design, installation, and maintenance of electrical resistance heat tracing in... Superseded Standard
515-1997 - the Testing, Design, Installation and Maintenance of Electrical Resistance Heat Tracing for Industrial ApplicationsThe specific test requirements for qualifying electrical resistance heating cables for industrial service are provided, as well as the basis for... Superseded Standard
515-2004 - the Testing, Design, Installation, and Maintenance of Electrical Resistance Heat Tracing for Industrial ApplicationsSpecific testing requirements for qualifying electrical resistance heating cables and heating devices for use in industrial applications, as well... Superseded Standard
515-2011 - the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial ApplicationsSpecific testing requirements for qualifying electrical resistance heating cables and heating devices for use in industrial applications, as well... Active Standard
515.1-1995 - Recommended Practice for the Testing, Design, Installation, and Maintenance of Electrical Resistance Heat Tracing for Commercial ApplicationsIn this IEEE standard the specific test requirements for qualifying electrical resistance heating cables for commercial service and a basis for... Superseded Standard
515.1-2005 - the Testing, Design, Installation, and Maintenance of Electrical Resistance Heat Tracing for Commercial ApplicationsSpecific test requirements for qualifying electrical resistance heat tracing for commercial service. A basis for electrical and thermal design is... Superseded Standard
515.1-2012 - the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Commercial ApplicationsSpecific test requirements for qualifying electrical resistance trace heating for commercial service are provided in this standard. A basis for... Active Standard
518-1982 - Guide for the Installation of Electrical Equipment to Minimize Electrical Noise Inputs to Controllers from External SourcesThis guide is limited to techniques for the installation of controllers and control systems so that proper operation can be achieved in the... Withdrawn Standard
519-1981 - Guide for Harmonic Control and Reactive Compensation of Static Power ConvertorsThis guide applies to all types of static power converters used in industrial and commercial power systems. The purpose is to discuss the problems... Superseded Standard
519-1992 - Recommended Practices and Requirements for Harmonic Control in Electrical Power SystemsThis guide applies to all types of static power converters used in industrial and commercial power systems. The problems involved in the harmonic... Superseded Standard
519-2014 - Recommended Practice and Requirements for Harmonic Control in Electric Power SystemsGoals for the design of electrical systems that include both linear and nonlinear loads are established in this recommended practice. The voltage... Active Standard
522-1992 - Guide for Testing Turn-to-Turn Insulation on Form-Wound Stator Coils for Alternating-Current Rotating Electric MachinesIn this standard, suggestions are made for testing the dielectric strength of the insulation separating the various turns from each other within... Superseded Standard
522-2004 - Guide for Testing Turn Insulation of Form-Wound Stator Coils for Alternating-Current Electric MachinesSuggestions are made for testing the dielectric strength of the insulation separating the various turns from each other within multiturn form... Active Standard
525-1987 - Guide for the Design and Installation of Cable Systems in SubstationsThis standard has been developed as a guide for the design, installation, and protection of wire and cable systems in substations with the... Superseded Standard
525-1992 - Guide for the Design and Installation of Cable Systems in SubstationsGuidance for the design, installation, and protection of wire and cable systems in substations with the objective of minimizing cable failures and... Superseded Standard
525-2007 - Guide for the Design and Installation of Cable Systems in SubstationsThe design, installation, and protection of wire and cable systems in substations are covered in this guide, with the objective of minimizing... Active Standard
532-1993 - Guide for Selecting and Testing Jackets for Underground CablesThis guide covers corrosion protection, properties of commonly used jackets, electrical characteristics of jackets, physical requirements for... Superseded Standard
532-2007 - Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control CablesThis guide covers properties of commonly used jackets as well as selection and testing of jackets. It is written for those responsible for... Active Standard
548-1984 - Standard Criteria and Guidelines for the Laboratory Measurement and Reporting of Fly Ash ResistivityUniform criteria and guidelines for laboratory measurement and reporting of fly ash resistivity data obtained in the laboratory are presented. Fly... Withdrawn Standard
551-2006 - Recommended Practice for Calculating AC Short-Circuit Currents in Industrial and Commercial Power SystemsThis recommended practice provides short-circuit current information including calculated short-circuit current duties for the application in... Active Standard
563-1978 - Guide on Conductor Self-Damping MeasurementsWith the increasing interest and concern regarding the vibration of overhead conductors, and the emphasis on the improvement of existing methods... Active Standard
575-1988 - Guide for Application of Sheath-Bonding Methods for Single-Conductor Cables and the Calculation of Induced Voltages and Currents in Cable SheathsThe guide describes the most common sheath-bonding systems now in use and the methods of calculating sheath voltages and currents, particularly as... Withdrawn Standard
575-2014 - Approved Draft Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5 kV through 500 kVThis guide describes the most common sheath-bonding systems now in use on high voltage single-conductor shielded power cables and the methods of... Active Standard
576-1989 - Recommended Practice Installation, Termination, and Testing of Insulated Power Cable as Used in the Petroleum and Chemical IndustryThe recommended practice provides a guide to installation, splicing, termination, and field-proof testing of cable systems for the petrochemical... Superseded Standard
576-2000 - Recommended Practice for Installation, Termination, and Testing of Insulated Power Cable as Used in Industrial and Commercial ApplicationsA guide for installing, splicing, terminating, and field proof testing of cable systems in industrial and commercial applications is provided. It... Active Standard
583-1982 - Standard Modular Instrumentation and Digital Interface System (CAMAC) (Computer Automated Measurement and Control)The interface system on which this standard is based was developed by the ESONE Committee of European Laboratories with the collaboration of the... Active Standard
592-1977 - Exposed Semiconducting Shields on Premolded High Voltage Cable Joints and Separable Insulated ConnectorsCable accessories, specifically separable insulated connectors and cable joints, used with extruded dielectric cable rated above 5 kV, are... Superseded Standard
592-1990 - Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable Insulated ConnectorsThis standard covers design tests for shield resistance and a simulated fault-current initiation for exposed semiconducting shields used on cable... Withdrawn Standard
592-2007 - Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable ConnectorsDesign test for shield resistance and a simulated fault-current initiation for exposed semiconducting shields used on cable accessories,... Active Standard
595-1982 - Standard Serial Highway Interface System (CAMAC) (Computer Automated Measurement and Control)The IEEE standard defines a serial highway interface system using byte-organized messages, and configured as a unidirectional loop to which are... Active Standard
596-1982 - Standard Parallel Highway Interface System (CAMAC) (Computer Automated Measurement and Control)The CAMAC parallel highway interface system for interconnecting up to seven CAMAC crates (or other devices) and a system controller is defined. In... Active Standard
597-1983 - Standard Practices and Requirements for General Purpose Thyristor DC DrivesLine-commutated semiconductor power converters for general-purpose industrial dc motor drives powered from three-phase or single-phase ac supplies... Withdrawn Standard
602-1986 - Recommended Practice for Electric Systems in Health Care FacilitiesThese recommended practices will aid electrical systems designers in achieving safety of life and preservation of property through operational... Superseded Standard
602-1996 - Recommended Practice for Electric Systems in Health Care FacilitiesA recommended practice for the design and operation of electric systems in health care facilities is provided. The term fi(h)ealth care facility... Superseded Standard
602-2007 - Recommended Practice for Electric Systems in Health Care FacilitiesA recommended practice for the design and operation of electric systems in health care facilities is provided. The term health care facility as... Active Standard
605-1987 - Guide for Design of Substation Rigid-Bus StructuresSubstation rigid-bus structures reduce substation heights, have greater ampacity and lower corona than single conductor strain bus structures. The... Withdrawn Standard
605-1998 - (Superseded) Guide for the Design of Substation Rigid-Bus StructuresRigid-bus structures for outdoor and indoor, air-insulated, and alternating-current substations are covered. Portions of this guide are also... Superseded Standard
605-2008 - Guide for Bus Design in Air Insulated SubstationsA proper design of the substation bus ensures a safe and reliable operation of the substation and the power system. Two different types of buses... Active Standard
620-1987 - Guide for Construction and Interpretation of Thermal Limit Curves for Squirrel-Cage Motors Over 500 hpAssists in a uniform understanding of the construction, interpretation, and use of motor thermal limit curves. The author defines thermal limit... Withdrawn Standard
620-1996 - Guide for the Presentation of Thermal Limit Curves for Squirrel Cage Induction MachinesIn this IEEE standard thermal limit curves for induction machines are defined. A procedure is established for the presentation of these curves,... Active Standard
625-1979 - Recommended Practices to Improve Electrical Maintenance and Safety in the Cement IndustryThis IEEE recommended practice defines and recommends practices for improving electrical maintenance and safety in the cement industry. These... Superseded Standard
625-1990 - Recommended Practice to Improve Electrical Maintenance and Safety in the Cement IndustryThe IEEE recommended practice assists in the effective application of relays and other devices for the protection of shunt capacitors used in... Superseded Standard
625-2001 - Recommended Practice to Improve Electrical Maintenance and Safety in the Cement IndustryThese recommended practices are intended as a reference document for use by members of cement industry electrical maintenance departments. The... Withdrawn Standard
634-1978 - Standard Cable Penetration Fire Stop QualificationThis standard provides qualification test procedures for type testing cable penetration fire stops when mounted in rated fire barriers. In the... Withdrawn Standard
634-2005 - Cable-Penetration Fire Stop Qualification TestRevision of IEEE Std 634-1978 This standard is applicable to fire stops of various materials and construction. Cablepenetration fire stops are... Active Standard
635-1989 - Guide for Selection and Design of Aluminum Sheaths for Power CablesThe purpose of this guide is as follows: to outline requirements and establish design guidelines for the selection of aluminum sheaths for extra... Superseded Standard
635-2003 - Guide for Selection and Design of Aluminum Sheaths for Power CablesDesign guidelines for cables with aluminum sheaths on low-, medium-, and high-voltage cables are provided. The aluminum sheath is an impervious... Active Standard
644-1987 - Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power LinesEstablishes uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current (AC) overhead power... Withdrawn Standard
644-1994 - Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power LinesIn this IEEE Standard uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current (AC)... Active Standard
656-1985 - the Measurement of Audible Noise from Overhead Transmission LinesThe purpose of this standard is to establish uniform procedures for the measurement of audible noise from overhead transmission lines, using... Superseded Standard
656-1992 - the Measurement of Audible Noise from Overhead Transmission LinesIn this standard uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their... Active Standard
664-1980 - Guide on the Measurement for the Performance of Aeolian Vibration Dampers for Single ConductorsThe basic engineering approach to the control of vibration of overhead conductors is to compare, at an acceptable amplitude, the wind power input... Superseded Standard
664-1993 - Guide for Laboratory Measurement of the Power Dissipation Characteristics of Aeolian Vibration Dampers for Single ConductorsThe current methodologies, including apparatus, procedures, and measurement accuracies, for determining the dynamic characteristics of vibration... Active Standard
666-1991 - Design Guide for Electric Power Service Systems for Generating StationsThis guide applies to power station service systems that supply electric power to auxiliary loads. The discussions and recommendations contained... Superseded Standard
666-2007 - Design Guide for Electric Power Service Systems for Generating StationsThis guide applies to station service systems that supply electric power to auxiliary loads for electric power generating stations. The... Active Standard
668-1987 - Recommended Practice for Electrical Heating Applications to Melting Furnaces and Forehearths in the Glass IndustryThe purpose of this recommended practice is to present procedures and positions preferred by the IEEE for using electric heating in the glass... Withdrawn Standard
675-1982 - Standard Multiple Controllers in a CAMAC Crate (Computer Automated Measurement and Control)This IEEE standard defines a method for incorporating more than one source of control into a CAMAC crate. The standard fully conforms to the... Active Standard
683-1976 - Recommended Practice for Block Transfers in CAMAC Systems (Computer Automated Measurement and Control)A wide variety of block transfer algorithms (or modes) are possible in CAMAC systems. However, a restricted number of such algorithms can satisfy... Active Standard
693-1984 - Recommended Practices for Seismic Design of SubstationsThe report presents recommended practises containing recommendations for the seismic design of substation facilities. Superseded Standard
693-1997 - Recommended Practices for Seismic Design of SubstationsRecommendations for seismic design of substations, including qualification of each equipment type, are discussed. Design recommendations consist... Superseded Standard
693-2005 - Recommended Practice for Seismic Design of SubstationsAbstract: Seismic design recommendations for substations, including qualification of each equipment type, are discussed. Design recommendations... Active Standard
726-1982 - Standard Real-Time BASIC for CAMAC (Computer Automated Measurement and Control)Real-time BASIC for CAMAC is ANSI standard real-time BASIC in which the declarations and real-time statements are defined for use with CAMAC... Active Standard
730-1989 - Software Quality Assurance PlansSuperseded Uniform minimum acceptable requirements for the preparation and content of Software Quality Assurance Plans (SQAPs) are provided. The... Superseded Standard
730-1998 - Software Quality Assurance PlansUniform, minimum acceptable requirements for the preparation and content of software quality assurance plans (SQAPs) are provided. This standard... Superseded Standard
730-2002 - Software Quality Assurance PlansThe standard specifies the format and content of software quality assurance plans. It meets the IEEE/EIA 12207.1 requirements for such plans. Superseded Standard
730-2014 - Software Quality Assurance ProcessesRequirements for initiating, planning, controlling, and executing the Software Quality Assurance processes of a software development or... Active Standard
739-1984 - Recommended Practice for Energy Conservation and Cost-Effective Planning in Industrial FacilitiesSuperseded by IEEE Std 739-1995 This recommended practice serves as an engineering guide for use in electrical design for energy conservation. It... Superseded Standard
739-1995 - Recommended Practice for Energy Management in Industrial and Commercial FacilitiesThis recommended practice serves as an engineering guide for use in electrical design for energy conservation. It provides a standard design... Active Standard
743-1984 - Standard Methods and Equipment for Measuring the Transmission Characteristics of Analog Voice Frequency CircuitsThe purpose of this standard is to establish functional requirements for measuring analog transmission characteristics of voice frequency... Superseded Standard
743-1995 - Standard Equipment Requirements and Measurement Techniques for Analog Transmission Parameters for TelecommunicationsPerformance requirements for test equipment that measures the analog transmission parameters of subscriber loops, message trunks, PBX trunks, and... Withdrawn Standard
746-1984 - Performance Measurements of A/D and D/A Converters for PCM Television Video CircuitsThis standard describes methods for measuring the performance of uniformly coded analog-to-digital (A/D) converters and digital-to-analog (D/A)... Withdrawn Standard
752-1986 - Functional Requirements for Methods and Equipment for Measuring the Performance of Tone Address Signal SystemsThis standard provides brief descriptions of applicable tone address signaling techniques and definitions of the related signaling parameters that... Withdrawn Standard
758-1979 - Standard Subroutines for Computer Automated Measurement and Control (CAMAC)This IEEE standard presents a recommended set of software subroutines for use with the CAMAC modular instrumentation and interface system of IEEE... Active Standard
762-1987 - Standard Definitions for Use in Reporting Electric Generating Unit Reliability, Availability, and ProductivityThe standard is intended to aid the electric power industry in reporting and evaluating electric generating unit reliability, availability and... Superseded Standard
762-2006 - Standard Definitions for Use in Reporting Electric Generating Unit Reliability, Availability, and ProductivityThis standard provides a methodology for the interpretation of electric generating unit performance data from various systems and to facilitate... Active Standard
790-1989 - Guide for Medical Ultrasound Field Parameter MeasurementsThis IEEE standard describes procedures for measuring medical ultrasound field parameters such as pressure, power and intensity. It is intended... Withdrawn Standard
792-1995 - Recommended Practice for the Evaluation of the Impulse Voltage Capability of Insulation Systems for AC Electric Machinery Employing Form-Wound Stator CoilsA test procedure for evaluation of the impulse voltage capability of insulation systems of form-wound alternating current rotating electrical... Withdrawn Standard
802-1955 - AIEE Proposed Trail Use Test Code DIRECT -- CURRENT CARBON -- PILE VOLTAGE REGULATORS for AIRCRAFTIt is the purpose of this code to define uniform acceptable methods of making tests to determine that the rating, performance and other... Withdrawn Standard
802-1990 - Standard: Overview and ArchitectureThis standard provides an overview to the family of IEEE 802 Standards, defines compliance with the family of IEEE 802 Standards, describes the... Superseded Standard
802-2001 - Overview and ArchitectureIEEE Std 802-2001 is the IEEE standard for local and metropolitan area networks. It provides an overview to the family of IEEE 802 standard and... Superseded Standard
802-2014 - Overview and ArchitectureThis standard provides an overview to the family of IEEE 802® standards. It describes the reference models for the IEEE 802 standards and explains... Active Standard
802.3j-1993 - Supplement to 802.3 - Fiber Optic Active and Passive Star-Based Segments, Type 10BASE-F (Sections 15-18)Superseded by IEEE Std 802.3-2002 This amendment to IEEE Std 802.3-2002, as amended by IEEE Std 802.3ae-2002 10Gb/s Ethernet and IEEE Std 802.3af... Superseded Standard
802.4a-1986 - Local Area Network: Fiber Optic Token BusAdd additional physical layer and media specifications utilizing fiber optic media to IEEE Std 802.4. Withdrawn Standard
802.5j-1993 - Trial Use Information Processing Systems-Local Area Networks-Part 5: Token Ring Access Method and Physical Layer Spec.-Fiber Optic Media Station AttachmentSuperseded by IEEE Std 802.1b-1995 The functional, electrical, optical, and mechanical characteristics of a fibre optic interface for connecting a... Superseded Standard
802.11k-2008 - Specific requirements-- Part 11: Wireless LAN Medium Access Control (MAC)and Physical Layer (PHY) Specifications Amendment 1: Radio Resource Measurement of Wireless LANsThis amendment specifies the extensions to IEEE Std 802.11 for Wireless LANs providing mechanisms for Radio Resource Measurement. Superseded Standard
816-1987 - Guide for Determining the Smoke Generation of Solid Materials Ued for Insulations and Coverings of Electric Wire and CableThe guide is to aid wire and cable manufacturers in the study of smoke generation characteristics of materials used in products. The two test... Withdrawn Standard
817-1993 - Standard Test Procedure for Flame-Retardant Coatings Applied to Insulated Cables in Cable TraysA test protocol and the performance criteria to determine the flame propagation tendency of flame-retardant coated cables in a vertical cable tray... Withdrawn Standard
835-1994 - Standard Power Cable Ampacity TablesOver 3000 ampacity tables for extruded dielectric power cables rated through 138 kV and laminar dielectric power cables rated through 500 kV are... Active Standard
835a-2012 - Standard Power Cable Ampacity Tables Amendment 1: Revision to IntroductionCorrections to the introduction for the standard with over 3000 ampacity tables for extruded dielectric power cables rated through 138 kV and... Active Standard
837-1989 - Qualifying Permanent Connections Used in Substation GroundingThis IEEE standard has been written to fill a need for standardization of terminology and test requirements for permanent grounding connections... Superseded Standard
837-2002 - Qualifying Permanent Connections Used in Substation GroundingDirection and methods for qualifying permanent connections used for substation grounding are provided in this standard. This standard particularly... Active Standard
839-1986 - Guide on Procedures for Testing Single-Phase and Polyphase Induction Motors for Use in Hermetic CompressorsThis guide specifies test procedures to determine the efficiency and other performance characteristics of hermetic motors. Hermetic motors are... Withdrawn Standard
841-1986 - Recommended Practice for Chemical Industry Severe Duty Squirrel-Cage Induction Motors-600 V and BelowThe purpose is to define and recommend specifications that deal with mechanical and electrical design, electrical insulation systems, corrosion... Superseded Standard
841-1994 - Petroleum and Chemical Industry - Severe Duty Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors - Up to and Including 500 hpThis standard applies to high-effi(c)iency TEFC, horizontal and vertical, single-speed, squirrel cage polyphase induction motors, up to and... Superseded Standard
841-2001 - Petroleum and Chemical Industry - Severe Duty Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors - Up to and Including 370 kW (500 hp)This standard applies to high-efficiency totally enclosed fan-cooled (TEFC), horizontal and vertical, single-speed, squirrel cage polyphase... Superseded Standard
841-2009 - Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp)This standard applies to premium efficiency totally enclosed fan-cooled (TEFC), horizontal and vertical, single-speed, squirrel cage polyphase... Active Standard
844-1991 - Recommended Practice for Electrical Impedance, Induction, and Skin Effect Heating of Pipelines and VesselsRecommended practices are provided for the design, installation, testing, operation, and maintenance of impedance, induction, and skin-effect... Superseded Standard
844-2000 - Recommended Practice for Electrical Impedance, Induction, and Skin Effect Heating of Pipelines and VesselsRecommended practices are provided for the design, installation, testing, operation, and maintenance of impedance, induction, and skin-effect... Active Standard
848-1996 - Standard Procedure for the Determination of the Ampacity Derating of Fire-Protected CablesA detailed test procedure is provided for determining the ampacity or derating factor in the following cable installation configurations: block... Active Standard
858-1987 - Standard Definitions in Power Operations TerminologyThis standard is a revision of Part 1 of IEEE Std. 346-1973, Glossary of Power Operations Terms. It is intended for engineers in power systems... Superseded Standard
858-1993 - Standard Definitions in Power Operations TerminologyTerms in the field of power operations are defined. Power distribution and transmission aspects are covered. Withdrawn Standard
859-1987 - Standard Terms for Reporting and Analyzing Outage Occurrences and Outage States of Electrical Transmission FacilitiesThe report is intended to aid the electric power industry in reporting and analyzing outrage occurrences of transmission facilities. Use of... Active Standard
902-1998 - Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book)Guidelines for the numerous personnel who are responsible for safely operating and maintaining industrial and commercial electric power facilities... Active Standard
930-1987 - Guide for the Statistical Analysis of Electrical Insulation Voltage Endurance DataThe guide describes, with examples, statistical methods to analyze the data for time-to-failure from constant-stress voltage endurance tests or... Superseded Standard
930-2004 - (Replaced) Guide for the Statistical Analysis of Electrical Insulation Breakdown DataThis guide describes, with examples, statistical methods to analyze times to break down and breakdown voltage data obtained from electrical... Active Standard
944-1986 - Recommended Practice for the Application and Testing of Uninterruptible Power Supplies for Power Generating StationsThe application and performance requirements for a low-voltage uninterruptible power supply system used for service in power generating stations... Withdrawn Standard
946-1985 - Recommended Practice for the Design of Safety-Related DC Auxiliary Power Systems for Nuclear Power Generating StationsGuidance for the design of the dc auxiliary power systems for nuclear and large fossil-fueled power generating stations is provided. The... Superseded Standard
946-1992 - Recommended Practice for the Design of DC Auxiliary Power Systems for Generating StationsGuidance for the design of the DC auxiliary power systems for nuclear and large fossil-fueled power generating stations is provided. The... Superseded Standard
946-2004 - Recommended Practice for the Design of DC Auxiliary Power Systems for Generating SystemsGuidance for the design of the dc auxiliary power systems for nuclear and non-nuclear power generating stations is provided by this recommended... Active Standard
952-1997 - Standard Specification Format Guide and Test Procedure for Single-Axis Interferometric Fiber Optic GyrosSpecification and test requirements for a single-axis interferometric fiber optic gyro ( I FOG) for use as a sensor in attitude control systems,... Active Standard
972-1985 - Trial-Use Connections of Insulated Aluminum ConductorsThis standard covers connectors used for making electrical connections between insulated aluminum cables rated 601 V through 46 000 V. This... Withdrawn Standard
977-1991 - Guide to Installation of Foundations for Transmission Line StructuresVarious approaches to good construction practices that could improve the installation of transmission line structure foundations are presented.... Superseded Standard
977-2010 - Guide to Installation of Foundations for Transmission Line StructuresVarious approaches to good construction practices that could improve the installation of transmission line structure foundations are presented.... Active Standard
978-1984 - Guide for In-Service Maintenance and Electrical Testing of Live-Line ToolsThis guide provides recommendations for in-service inspection, maintenance, and electrical testing of live-line tools. These selected... Withdrawn Standard
979-1984 - Guide for Substation Fire Protection Substation fire-protection practices that generally have been accepted by the electric utility industry and existing fire- protection standards... Superseded Standard
979-1994 - Guide for Substation Fire ProtectionIn this IEEE standard guidance is provided to substation engineers in determining the design, equipment and practices deemed necessary for the... Superseded Standard
979-2012 - Guide for Substation Fire ProtectionGuidance is provided to substation engineers in determining the design, equipment, and practices deemed necessary for the fire protection of... Active Standard
980-1987 - Guide for Containment and Control of Oil Spills in SubstationsThe guide discusses the significance of federal oil spillage regulations and their applicability to substations; identifies the problem of oil... Superseded Standard
980-1994 - Guide for Containment and Control of Oil Spills in SubstationsIn this IEEE standard the significance of oil-spillage regulations and their applicability to electric supply substations are discussed: the... Superseded Standard
980-2013 - Guide for Containment and Control of Oil Spills in SubstationsThe significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are... Active Standard
982.1-1988 - Standard Dictionary of Measures to Produce Reliable SoftwareThe standard provides a set of measures indicative of software reliability that can be applied to the software product as well as to the... Superseded Standard
982.1-2005 - Standard Dictionary of Measures of the Software Aspects of DependabilityA standard dictionary of measures of the software aspects of dependability for assessing and predicting the reliability, maintainability, and... Active Standard
982.2-1988 - Guide for the Use of IEEE Standard Dictionary of Measures to Produce Reliable SoftwareThe guide provides the conceptual insights, implementation considerations, and assessment suggestions for the application of IEEE Std 982.1-1988,... Withdrawn Standard
995-1987 - Recommended Practice for Efficiency Determination of Alternating-Current Adjustable Speed Drives: Part I - Load Commutated Inverter Synchronous Motor DrivesThis recommended practice proposes a method for determining the efficiency of large, adjustable-speed AC motor-drive systems consisting of a load... Withdrawn Standard
998-1996 - Guide for Direct Lightning Stroke Shielding of SubstationsDesign information for the methods, historically and typically applied by substation designers to minimize direct lightning strokes to equipment... Superseded Standard
998-2012 - Guide for Direct Lightning Stroke Shielding of SubstationsDesign information for the methods historically and typically applied by substation designers to reduce direct lightning strokes to equipment and... Active Standard
1001-1988 - Guide for Interfacing Dispersed Storage and Generation Facilities with Electric Utility SystemsThe purpose of this IEEE guide is to alert electric utilities, manufacturers of dispersed storage and generation (DSG) equipment, consultants,... Withdrawn Standard
1003.3-1991 - Test Methods for Measuring Conformance to POSIX(R)IEEE Std 1003.3-1991, IEEE Standard for Information Technology-Test Methods for Measuring Conformance to POSIX, defines the general requirements... Withdrawn Standard
1007-1991 - Standard Methods and Equipment for Measuring the Transmission Characteristics of Pulse-Code Modulation (PCM) Telecommunications Circuits and SystemsTest equipment requirements and methods for testing the transmission characteristics of PCM telecommunications equipment, circuits, and systems... Withdrawn Standard
1015-1997 - Recommended Practice for Applying Low-Voltage Circuit Breakers Used in Industrial and Commercial Power SystemsInformation is provided for selecting the proper circuit breaker for a particular application. This recommended practice helps the application... Superseded Standard
1015-2006 - Recommended Practice for Applying Low-Voltage Circuit Breakers Used in Industrial and Commercial Power SystemsInformation is provided for selecting the proper circuit breaker for a particular application. This recommended practice helps the application... Active Standard
1015-2006/Cor 1-2007 - Recommended Practice for Applying Low Voltage Circuit Breakers Used in Industrial and Commercial Power Systems - Corrigendum 1To correct technical omission/errors to IEEE Std 1015™-2006 Chapter 4 4.12 Normative references Annex 7A (informative) MCCB or MCP data record 7A... Active Standard
1017-1985 - Recommended Practice for Field Testing Electric Submersible Pump CableThe recommended practice, under the jurisdiction of the IEEE Industry Applications Society, Petroleum and Chemical Industry Committee, is... Superseded Standard
1017-1991 - Recommended Practice for Field Testing Electric Submersible Pump CableProcedures and test voltage values for acceptance and maintenance testing of electrical submersible pump cable systems are presented. This IEEE... Withdrawn Standard
1017-2004 - Recommended Practice for Field Testing Electric Submersible Pump CableProcedures and test voltage values for acceptance and maintenance testing of electrical submersible pump (ESP) cable systems are presented. This... Superseded Standard
1017-2013 - Recommended Practice for Field Testing Electric Submersible Pump CableProcedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This... Active Standard
1018-1985 - Recommended Practice for Specifying Electric Submersible Pump Cable-Ethylene Propylene Rubber InsulationThe recommended practice, under the jurisdiction of the IEEE Industry Applications Society, Petroleum and Chemical Industry Committee, presents... Superseded Standard
1018-1991 - Recommended Practice for Specifying Electric Submersible Pump Cable - Ethylene-Propylene Rubber InsulationIn this standard minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are... Withdrawn Standard
1018-2004 - Recommended Practice for Specifying Electric Submersible Pump Cable - Ethylene-Propylene Rubber InsulationMinimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable... Superseded Standard
1018-2013 - Recommended Practice for Specifying Electric Submersible Pump Cable—Ethylene-Propylene Rubber InsulationMinimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable... Active Standard
1019-1985 - Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene InsulationThe recommended practice, under the jurisdiction of the IEEE Industry Applications Society, Petroleum and Chemical Industry Committee, presents... Superseded Standard
1019-1991 - Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene InsulationSuperseded by IEEE Std 1019-2004 Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible... Withdrawn Standard
1019-2004 - Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene InsulationMinimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable... Superseded Standard
1019-2013 - Recommended Practice for Specifying Electric Submersible Pump Cable—Polypropylene InsulationMinimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are... Active Standard
1026-1995 - Recommended Practice for Test Methods for Determination of Compatibility of Materials With Conductive Polymeric Insulation Shields and JacketsIn this IEEE Standard a test method is provided to qualify various essentially nonvolatile, highly viscous fluids or solid materials at 90/spl deg... Withdrawn Standard
1027-1984 - Draft Trial-Use Standard Method for Measuring the Magnetic Field Intensity Around a Telephone ReceiverDescribes the methodology for determining the magnetic-field intensity in the proximity of a telephone receiver. The impetus for this work was... Superseded Standard
1027-1996 - Standard Method for Measurement of the Magnetic Field in the Vicinity of a Telephone ReceiverThe methodology for measuring the magnetic field strength in the vicinity of a telephone receiver is described. Withdrawn Standard
1037-1992 - Standard Terms and Definitions for Surface Acoustic Wave (SAW) DevicesThe following topics were dealt with: Terms and their definitions for surface acoustic wave devices are provided. The terms and definitions are... Withdrawn Standard
1045-1992 - Software Productivity MetricsA consistent way to measure the elements that go into computing software productivity is defined. Software productivity metrics terminology are... Withdrawn Standard
1048-1990 - Guide for Protective Grounding of Power LinesThe primary purpose of protective groundings is to limit the voltage difference between any two accessible points at the work site to a safe value... Superseded Standard
1048-2003 - Guide for Protective Grounding of Power LinesGuidelines for protective grounding methods for individuals engaged in de-energized overhead transmission and distribution line maintenance are... Active Standard
1068-1990 - Recommended Practice for Repair and Rewinding of Motors for the Petroleum and Chemical IndustryThis recommended practice is intended to be a basic or primary document that can be utilized and referenced by owners of electric motors that need... Superseded Standard
1068-1996 - Recommended Practice for the Repair and Rewinding of Motors for the Petroleum and Chemical IndustryGeneral recommendations are provided for users of motors that need repair as well as owners and operators of establishments that offer motor... Superseded Standard
1068-2009 - the Repair and Rewinding of AC Electric Motors in the Petroleum, Chemical, and Process IndustriesThis standard is intended to be a basic or primary document that can be utilized and referenced by owners of ac motors and generators (machines)... Active Standard
1076-1987 - Standard VHDL Language Reference ManualThe VHSIC Hardware Description Language (VHDL) is a formal notation intended for use in all phases of the creation of electronic systems. Because... Superseded Standard
1076-1993 - Standard VHDL Language Reference ManualThis standard defines the VHSIC Hardware Description Language (VHDL). VHDL is a formal notation intended for use in all phases of the creation of... Superseded Standard
1076-2000 - Standard VHDL Language Reference ManualVHSIC Hardware Description Language [VHDL] is defined. VHDL is a formal notation intended for use in all phases of the creation of electronic... Superseded Standard
1076-2002 - Standard VHDL Language Reference ManualVHSIC Hardware Description Language (VHDL) is defined. VHDL is a formal notation intended for use in all phases of the creation of electronic... Superseded Standard
1076-2008 - Standard VHDL Language Reference ManualVHSIC hardware description language (VHDL) is defined. VHDL is a formal notation intended for use in all phases of the creation of electronic... Active Standard
1076.1-1999 - Standard VHDL Analog and Mixed-Signal ExtensionsThis standard defines the IEEE 1076.1 language, a hardware description language for the description and the simulation of analog, digital, and... Superseded Standard
1076.1-2007 - (Withdrawn)Standard VHDL Analog and Mixed-Signal ExtensionsThis standard defines the IEEE 1076.1 language, a hardware description language for the description and the simulation of analog, digital, and... Active Standard
1076.1.1-2004 - Standard VHDL Analog and Mixed-Signal Extensions---Packages for Multiple Energy Domain SupportThis standard defines a collection of VHDL 1076.1 packages, compatible with IEEE Std 1076.1-1999, along with recommendations for conforming use,... Superseded Standard
1076.1.1-2011 - VHDL Analog and Mixed-Signal Extensions -- Packages for Multiple Energy Domain SupportThis standard defines a collection of VHDL 1076.1 packages, compatible with IEEE Std 1076.1, along with recommendations for conforming use, in... Active Standard
1076.2-1996 - Standard VHDL Mathematical PackagesThe MATH-REAL package declaration, the MATH-COMPLEX package declaration, and the semantics of the standard mathematical definition and the... Superseded Standard
1076.3-1997 - Standard VHDL Synthesis PackagesThe current interpretation of common logic values and the association of numeric values to specific VHDL array types is described. This standard... Superseded Standard
1076.4-1995 - Standard VITAL Application-Specific Integrated Circuit (ASIC) Modeling SpecificationThe VITAL (VHDL Initiative Towards ASIC Libraries) ASIC Modeling Specification is defined. It creates a methodology that promotes the development... Superseded Standard
1076.4-2000 - Standard VITAL ASIC (Application Specific Integrated Circuit) Modeling SpecificationThe VITAL (VHDL Initiative Towards ASIC Libraries)ASIC Modeling Specification is defined in this standard.This modeling specification defines a... Withdrawn Standard
1076.6-1999 - VHDL Register Transfer Level SynthesisA standard syntax and semantics for VHDL register transfer level (RTL) synthesis is defined. The subset of IEEE 1076 (VHDL) that is suitable for... Superseded Standard
1076.6-2004 - VHDL Register Transfer Level (RTL) SynthesisThis document specifies a standard for use of very high-speed integrated circuit hardware description language (VHDL) to model synthesizable... Withdrawn Standard
1076c-2007 - Standard VHDL Language Reference Manual - Procedural Language Application InterfaceThis amendment adds a simulation runtime application interface (VHDL Programming Interface or VHPI) to the existing base standard IEEE Std 1076-2002. Superseded Standard
1100-1992 - Recommended Practice for Powering and Grounding Sensitive Electronic EquipmentRecommended design, installation, and maintenance practices for electrical power and grounding (including both power-related and signal-related... Superseded Standard
1100-1999 - Recommended Practice for Powering and Grounding Electronic EquipmentRecommended design, installation, and maintenance practices for electrical power and grounding (including both power-related and signal-related... Superseded Standard
1100-2005 - Recommended Practice for Powering and Grounding Electronic EquipmentThe IEEE Emerald Book presents a collection of consensus best practices for the powering and grounding of electronic equipment used in commercial... Active Standard
1106-1987 - Recommended Practice for Maintenance, Testing, and Replacement of Nickel-Cadmium Storage Batteries for Generating Stations and SubstationsThis recommended practice provides maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of... Superseded Standard
1106-1995 - Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary ApplicationsInstallation design, installation, maintenance and testing procedures, and test schedules that can be used to optimize the life and performance of... Superseded Standard
1106-2005 - Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary ApplicationsThis recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be... Active Standard
1107-1996 - Recommended Practice for Thermal Evaluation of Sealed Insulation Systems for AC Electric Machinery Employing Random-Wound Stator CoilsIn this IEEE standard a test procedure for comparing expected life, at rated temperature, of two or more sealed insulation systems, is outlined.... Withdrawn Standard
1109-1990 - Guide for the Interconnection of User-Owned Substations to Electric UtilitiesThe report provides a checklist and selected guidance, for persons not normally practicing in this specialized field, of major technical design... Withdrawn Standard
1110-1991 - Guide for Synchronous Generator Modeling Practices in Stability AnalysesThis document has been written to assist the power system analyst in choosing appropriate synchronous generator models for power system stability... Superseded Standard
1110-2002 - Guide for Synchronous Generator Modeling Practices and Applications in Power System Stability AnalysesCategorizes three direct-axis and four quadrature-axis models, along with the basic transient reactance model. Discusses some of the assumptions... Active Standard
1115-1992 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary ApplicationsMethods for defining the dc load and for sizing a nickel-cadmium battery to supply that load are described. Installation, maintenance,... Superseded Standard
1115-2000 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary ApplicationsThe sizing of nickel-cadmium batteries used in full float operation for stationary applications is covered in this recommended practice. Active Standard
1115a-2007 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications Amendment 1: Additional Discussion on Sizing MarginsThis amendment provides additional guidance on sizing margins that may be applied when nickel-cadmium batteries are used in stationary... Active Standard
1119-1988 - Guide for Fence Safety Clearances in Electric-Supply StationsThe purpose of this standard is to provide design guidance for the location of fences with respect to live parts within an electric-supply station... Withdrawn Standard
1120-1990 - Guide to the Factors to Be Considered in the Planning, Design, and Installation of Submarine Power and Communications CablesThis guide presents a list of factors relating to power and communications cables installed in a submarine environment including the shore ends of... Superseded Standard
1120-2004 - Guide for the Planning, Design, Installation, and Repair of Submarine Power Cable SystemsThis guide provides a list of factors to consider when planning, designing, permitting, installing, commissioning, and repairing submarine power... Active Standard
1122-1987 - Digital Recorders for Measurements in High-Voltage Impulse TestsThe object of this standard is to define the terms specifically related to the digital recorders used for monitoring high-voltage (HV) and high... Superseded Standard
1122-1998 - Digital Recorders for Measurements in High-Voltage Impulse TestsThis standard defines the terms specifically related to the digital recorders used for monitoring high-voltage and high-current impulse tests,... Active Standard
1125-1994 - Guide for Moisture Measurement and Control in SF6 Gas-Insulated EquipmentReaffirmed 2004 Guidelines for moisture level measurement, moisture data interpretation, and moisture control in gas-insulated transmission class... Superseded Standard
1127-1990 - Guide for the Design, Construction, and Operation of Safe and Reliable Substations for Environmental AcceptanceMore and more substations are becoming necessary, due to the ever increasing load growth being evidenced by most electric utility companies and... Superseded Standard
1127-1998 - Guide for the Design, Construction, and Operation of Electric Power Substations for Community Acceptance and Environmental CompatibilitySignificant community acceptance and environmental compatibility items to be considered during the planning and design phases, the construction... Superseded Standard
1127-2013 - Guide for the Design, Construction, and Operation of Electric Power Substations for Community Acceptance and Environmental CompatibilitySignificant community acceptance and environmental compatibility items to be considered during the planning and design phases, the construction... Active Standard
1129-1992 - Recommended Practice for Monitoring and Instrumentation of Turbine GeneratorsA basic philosophy and guidelines are established for the design and implementation of monitoring systems for cylindrical-rotor, synchronous... Withdrawn Standard
1129-2014 - Guide for Online Monitoring of Large Synchronous Generators (10 MVA and Above)The guidelines for online monitoring of large synchronous generators are described in this guide. High-level discussions of each of the proposed... Active Standard
1138-1994 - Standard Construction of Composite Fiber Optic Groundwire (OPGW) for Use on Electric Utility Power LinesThe construction, mechanical and electrical performance, installation guidelines, acceptance criteria, and test requirements for a composite... Superseded Standard
1138-2009 - Testing and Performance for Optical Ground Wire (OPGW) for Use on Electric Utility Power LinesThis standard covers the performance, test requirements, procedures, and acceptance criteria for a transmission line overhead ground wire (a.k.a.... Active Standard
1139-1988 - Standard Definitions of Physical Quantities for Fundamental Frequency and Time MetrologyThis standard covers the fundamental metrology for describing physical quantities of importance to frequency and time metrology. Quantities... Withdrawn Standard
1139-1999 - Standard Definitions of Physical Quantities for Fundamental Frequency and Time Metrology-Random InstabilitiesMethods of describing random instabilities of importance to frequency and time metrology is covered in this standard. Quantities covered include... Superseded Standard
1139-2008 - Standard Definitions of Physical Quantities for Fundamental Frequency and Time Metrology--Random InstabilitiesMethods of describing random instabilities of importance to frequency and time metrology are covered. Quantities covered include frequency,... Active Standard
1140-1994 - Standard Procedures for the Measurement of Electric and Magnetic Fields from Video Display Terminals (VDTs) from 5 Hz to 400 kHzProcedures for the measurement of electric and magnetic fields in close proximity to video display terminals (VDTs) in the frequency range of 5 Hz... Active Standard
1142-1995 - Guide for the Design, Testing, and Application of Moisture-Impervious, Solid Dielectric, 5-35 kV Power Cable Using Metal-Plastic LaminatesIn this IEEE Standard the user of underground cables is provided with information on the design, testing, and application of moisture-impervious,... Withdrawn Standard
1142-2009 - Guide for the Selection, Testing, Application, and Installation of Cables having Radial-Moisture Barriers and/or Longitudinal Water BlockingDetailed information relating to the design, testing, application and installation of various types of electrical cables in order to prevent the... Active Standard
1143-1994 - Guide on Shielding Practice for Low Voltage CablesThis IEEE guide provides the following: an enumeration of sources of electrostatic and electromagnetic interference; a review of shielding... Superseded Standard
1143-2012 - Guide on Shielding Practice for Low Voltage CablesA concise overview of shielding options for various types of interference is discussed in this guide. Recommendations on shielding practices for... Active Standard
1159-1995 - Recommended Practice for Monitoring Electric Power QualityThe monitoring of electric power quality of single-phase and polyphase AC power systems, definitions of power quality terminology, impact of poor... Superseded Standard
1159-2009 - Recommended Practice for Monitoring Electric Power QualityThis recommended practice encompasses the monitoring of electrical characteristics of single-phase and polyphase ac power systems. It includes... Active Standard
1159.3-2003 - Recommended Practice for the Transfer of Power Quality DataThis recommended practice defines a file format suitable for exchanging power quality related measurement and simulation data in a vendor... Active Standard
1160-1993 - Standard Test Procedures for High-Purity Germanium Crystals for Radiation DetectorsThis standard applies to the measurement of bulk properties of high-purity germanium as they relate to the fabrication and performance of... Active Standard
1184-1994 - Guide for the Selection and Sizing of Batteries for Uninterruptible Power SystemsThe characteristics of the various battery energy systems available are described so that users can select the system best suited to their... Superseded Standard
1184-2006 - Guide for Batteries for Uninterruptible Power Supply SystemsVarious battery systems are discussed so that the user can make informed decisions on selection, installation design, installation, maintenance,... Active Standard
1185-1994 - Guide for Installation Methods for Generating Station CablesInstallation methods to improve cable installation practices in generating stations are provided. These include cable lubrication methods, conduit... Superseded Standard
1185-2010 - Recommended Practice for Cable Installation in Generating Stations and Industrial FacilitiesGuidance for the proper installation of cable in generating stations and industrial facilities is provided. Active Standard
1187-1996 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Storage Batteries for Stationary ApplicationsThis IEEE standard covers recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
1187-2002 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary ApplicationsThis recommended practice provides guidance for the installation and installation design of valve-regulated lead acid (VRLA) batteries. This... Superseded Standard
1187-2013 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary ApplicationsThis recommended practice provides guidance for the installation and installation design of valve-regulated lead acid (VRLA) batteries. This... Active Standard
1188-1996 - Recommended Practice for Maintenance, Testing, and Replacement of Valve- Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsIn this IEEE standard maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of valve-regulated... Superseded Standard
1188-2005 - Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsThis recommended practice is limited to maintenance, test schedules, and testing procedures that can be used to optimize the life and performance... Active Standard
1189-1996 - Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsMethods for selecting the appropriate type of valve-regulated, immobilized-electrolyte, recombinant lead-acid battery for any of a variety of... Superseded Standard
1189-2007 - Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsThis guide describes methods for selecting the appropriate type of valve-regulated, immobilized-electrolyte, recombinant lead-acid battery for any... Active Standard
1193-1994 - Guide for Measurement of Environmental Sensitivities of Standard Frequency GeneratorsStandard frequency generators that include all atomic frequency standards and precision quartz crystal oscillators are addressed. There are three... Superseded Standard
1193-2003 - Guide for Measurement of Environmental Sensitivities of Standard Frequency GeneratorsStandard frequency generators that include all atomic frequency standards, quartz oscillators, dielectric resonator oscillators, yttrium-iron... Active Standard
1202-1991 - Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial OccupanciesA test protocol and the performance criteria to determine the flame propagation tendency of cables in a vertical cable tray are presented. They... Superseded Standard
1202-2006 - Flame-Propagation Testing of Wire & CableStandardization of cable flame propagation testing is beneficial to cable manufacturers, distributors, and users. Uniform procedures; consistent,... Active Standard
1202-2006/Cor 1-2012 - Flame-Propagation Testing of Wire and Cable - Corrigendum 1Corrected English unit conversions are included in this corrigendum to IEEE Std 1202-2006. Active Standard
1206-1994 - Standard Methods for Measuring Transmission Performance of Telephone Handsets and HeadsetsPractical methods for measuring the transmission characteristics of a telephone handset or headset by means of using a test connection to obtain... Superseded Standard
1210-1996 - Standard Tests for Determining Compatibility of Cable-Pulling Lubricants With Wire and CableCriteria and test methods for determining the compatibility of cable-pulling lubricants (compounds) with cable jacket or other exterior cable... Superseded Standard
1210-2004/Cor 1-2014 - Standard Tests for Determining Compatibility of Cable-Pulling Lubricants with Wire and Cable - Corrigendum 1Criteria and test methods for determining the compatibility of cable-pulling lubricants (compounds) with cable jacket or other exterior cable... Active Standard
1210-2005 - Standard Tests for Determining Compatibility of Cable-Pulling Lubricants With Wire and CableCriteria and test methods for determining the compatibility of cable-pulling lubricants (compounds) with cable jacket or other exterior cable... Active Standard
1215-2001 - Guide for the Application of Separable Insulated ConnectorsThis guide provides general information on the application and operation of separable connectors. It is intended to be basic, and supplement the... Superseded Standard
1215-2013 - Guide for the Application of Separable Insulated ConnectorsGeneral information on the application and operation of separable connectors is provided in this guide. It is intended to be basic and supplement... Active Standard
1216-2000 - Guide for the Application of Faulted Circuit Indicators for 200 A, Single-Phase Underground Residential Distribution (URD)This application guide provides information on what a basic faulted circuit indicator (FCI) is designed to do, and describes methods for selecting... Active Standard
1222-2003 - All-Dielectric Self-Supporting Fiber Optic CableSUMMARY: This standard covers construction, mechanical, electrical, and optical performance, installation guidelines, acceptance criteria, test... Superseded Standard
1222-2011 - Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power LinesThis standard covers the construction, mechanical, electrical and optical performance, installation guidelines, acceptance criteria, test... Active Standard
1227-1990 - Guide for the Measurement of DC Electric-Field Strength and Ion Related QuantitiesThe purpose of this document is to provide guidance for the measurement of the electric field strength, ion-current density, conductivity,... Active Standard
1234-2007 - Guide for Fault Locating Techniques on Shielded Power Cable SystemsTests and measurements that are performed on shielded power cables to identify the location of a fault are described. Whenever possible, the... Active Standard
1234-2007 - Guide for Fault Locating Techniques on Shielded Power Cable SystemsTests and measurements that are performed on shielded power cables to identify the location of a fault are described. Whenever possible, the... Active Standard
1235-2000 - Guide for the Properties of Identifiable Jackets for Underground Power Cables and DuctsIdentification markings of jacketed underground power cables and ducts are established in this guide. Included are various methods of identifying... Active Standard
1242-1999 - Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical PlantsInformation on the specification and selection of power, control, and special-purpose cable, as typically used in petroleum, chemical, and similar... Active Standard
1243-1997 - Guide for Improving the Lightning Performance of Transmission LinesThe effects of routing, structure type, insulation, shielding and grounding on transmission lines are discussed. The way these transmission-line... Active Standard
1255-2000 - Guide for Evaluation of Torque Pulsations During Starting of Synchronous MotorsA uniform method for calculating and measuring torque pulsations that occur during starting of synchronous motors is provided. Synchronous motors,... Active Standard
1260-1996 - Guide on the Prediction, Measurement, and Analysis of AM Broadcast Reradiation by Power LinesIn this IEEE standard a set of procedures to be followed to cope with reradiation of AM broadcast signals from power lines and other large... Active Standard
1284-1994 - Standard Signaling Method for a Bidirectional Parallel Peripheral Interface for Personal ComputersA signaling method for asynchronous, fully interlocked, bidirectional parallel communications between hosts and printers or other peripherals is... Superseded Standard
1284-2000 - Standard Signaling Method for a Bidirectional Parallel Peripheral Interface for Personal ComputersA signaling method for asynchronous, fully interlocked, bidirectional parallel communi-cations between hosts and printers or other peripherals is... Active Standard
1291-1993 - Guide for Partial Discharge Measurement in Power SwitchgearThis guide defines methods of measuring partial discharges that may occur in energized power switchgear apparatus in flaws, voids, and interfaces... Withdrawn Standard
1299-1996 - Guide for the Connection of Surge Arresters to Protect Insulated, Shielded Electric Power Cable SystemsThis guide suggests surge arrester installation methods at distribution cable terminal poles in order to minimize the total impressed transient... Active Standard
1300-1996 - Guide for Cable Connections for Gas-Insulated SubstationsIn this IEEE standard the coordination of design, material supply, installation, and test procedures required for the connection of a gas... Superseded Standard
1300-2011 - Guide for Cable Connections for Gas-Insulated SubstationsThis guide establishes typical dimensions for connections of a gas-insulated substation (GIS) to extruded, self contained fluid-filled, and high... Active Standard
1309-1996 - Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHzConsensus calibration methods for electromagnetic field sensors and field probes are provided. Data recording and reporting requirements are given... Superseded Standard
1309-2005 - Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHzConsensus calibration methods for electromagnetic (EM) field sensors and probes are provided. Data recording and reporting requirements are given,... Superseded Standard
1309-2013 - Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHzConsensus calibration methods for electromagnetic (EM) field sensors and probes are provided. Data recording and reporting requirements are given,... Active Standard
1310-1996 - Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large GeneratorsIn this IEEE standard a test method to determine the relative ability of high-voltage, form-wound stator bars and coils of large rotating machines... Superseded Standard
1310-2012 - Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating MachinesThis procedure is intended for form-wound bars/coils for rotating machines rated 10 kV or more at 50 Hz or 60 Hz that are subjected to many... Active Standard
1313-1993 - Power Systems - Insulation CoordinationEquipment for three-phase alternating-current (ac) systems having a system voltage above 1 kV nominal is discussed. Except for some definitions,... Superseded Standard
1313.1-1996 - Insulation Coordination - Definitions, Principles and RulesIn this IEEE standard the procedure for selection of the withstand voltages for equipment phase-to-ground and phase-to-phase insulation systems is... Superseded Standard
1313.2-1999 - Guide for the Application of Insulation CoordinationThe calculation method for selection of phase-to-ground and phase-to-phase insulation withstand voltages for equipment is presented. This guide... Active Standard
1326-1993 - Test Methods for Measuring Conformance to Open Systems Interconnection (OSI) Abstract Data Manipulation - Application Program Interface (API) [Language Independent]Test methods for measuring conformance to IEEE Std 1224-1993, which defines a general purpose OSI Abstract Data Manipulation (OM) Application... Withdrawn Standard
1326.1-1993 - Test Methods for Measuring Conformance to X.400 Based Electronic Messaging Application Program Interfaces (API) [Language Independent]The test methods that may be used to test conformance to IEEE Std 1224.1-1993, IEEE Standard for Information Technology Open Systems... Withdrawn Standard
1326.2-1993 - Test Methods for Measuring Conformance to Directory Services--Application Program Interface (API) [Language Independent]Test methods for IEEE Std 1224.2-1993 language-independent specification of the applications interface to directory services are defined. Withdrawn Standard
1328-1993 - Test Methods for Measuring Conformance to Open Systems Interconnection (OSI) Abstract Data Manipulation C Language Interfaces--Binding for Application Program Interface (API)Test methods that may be used to test conformance to IEEE Std 1327-1993, IEEE Standard for Information Technology" Open Systems Interconnection ... Withdrawn Standard
1328.1-1993 - Test Methods for Measuring Conformance to X.400 Based Electronic Messaging C Language Interfaces--Binding for Application Program Interfaces (API)This standard defines test methods that may be used to test conformance to IEEE Std 1327.11993, which is a C language binding for IEEE Std 1224.1... Withdrawn Standard
1328.2-1993 - Test Methods for Measuring Conformance to Directory Services C Language Interfaces--Binding for Application Program Interface (API)Test methods for the C language binding defined in IEEE Std 1327.2-1993 for the applications interface to directory services defined in IEEE Std... Withdrawn Standard
1329-1999 - Standard Method for Measuring Transmission Performance of Handsfree Telephone SetsTechniques for objective measurement of electroacoustic and voice switching characteristics of analog and digital handsfree telephones (HFTs) are... Superseded Standard
1329-2010 - Standard Method for Measuring Transmission Performance of SpeakerphonesThis standard provides techniques for objective measurement of electroacoustic and voice-switching characteristics of speakerphones that connect... Active Standard
1333-1994 - Guide for Installation of Cable Using the Guided Boring MethodIn this IEEE standard the method and equipment involved in proper and economical installation of insulated conductors and/or conduits using the... Withdrawn Standard
1346-1998 - Recommended Practice for Evaluating Electric Power System Compatibility With Electronic Process EquipmentA standard methodology for the technical and financial analysis of voltage sag compatibility between process equipment and electric power systems... Withdrawn Standard
1349-2001 - Guide for Application of Electric Motors in Class I, Division 2 Hazardous (Classified) LocationsThis guide was developed to assist individuals, organizations, and suppliers with the application of motors in Class I, Division 2 locations,... Superseded Standard
1349-2011 - Guide for Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) LocationsThree-phase and single-phase AC synchronous and induction electric motors in ratings 0.18 kW (1/4 hp) and larger are covered in this guide.... Active Standard
1368-2006 - Guide for Aeolian Vibration Field Measurements of Overhead ConductorsCurrent practices related to field measurements of aeolian vibration of overhead conductors are covered in this guide. Active Standard
1393-1999 - Spaceborne Fiber Optic Data BusThe design requirements for a fiber-optic serial interconnect protocol, topology, and media is established. The application target for this... Withdrawn Standard
1406-1998 - Guide to the Use of Gas-In-Fluid Analysis for Electric Power Cable SystemsIn this standard, the application of the analysis of gases dissolved in the fluids of fluid-filled cable systems is discussed with respect to the... Active Standard
1407-1998 - Guide for Accelerated Aging Tests for Medium-Voltage Extruded Electric Power Cables Using Water-Filled TanksAccelerated aging tests on extruded medium-voltage cables using water-filled tanks are addressed. Information on the equipment, cable samples,... Superseded Standard
1407-2007 - Guide for Accelerated Aging Tests for Medium-Voltage (5 kV-35 kV) Extruded Electric Power Cables Using Water-Filled TanksAccelerated aging tests on extruded medium-voltage cables using water-filled tanks are addressed. Information on the equipment, cable samples,... Active Standard
1415-2006 - Guide for Induction Machinery Maintenance Testing and Failure AnalysisThis guide provides maintenance testing and failure analysis guidance for form-wound, squirrel cage, induction machinery rated up to 15 kV. It... Active Standard
1425-2001 - Guide for the Evaluation of the Remaining Life of Impregnated Paper-Insulated Transmission Cable SystemsThis guide provides technical information regarding factors that can affect the life of an impregnated paper-insulated transmission cable system,... Active Standard
1428-2004 - Guide for Installation Methods for Fiber Optic Cables in Electric Power Generating Stations and in Industrial FacilitiesThis guide is intended for cables designed for use in power generating stations and industrial facilities, in both the outside plant environment... Active Standard
1434-2000 - Guide to the Measurement of Partial Discharges in Rotating MachineryA review of the nature of partial discharge in machine windings, how it can be measured under both off-line and on-line conditions, how it can be... Active Standard
1453-2004 - Recommended Practice for Measurement and Limits of Voltage Fluctuations and Associated Light Flicker on AC Power SystemsVoltage fluctuations on electric power systems sometimes give rise to noticeable illumination changes from lighting equipment. This phenomenon is... Withdrawn Standard
1453-2011 - Recommended Practice--Adoption of IEC 61000-4-15:2010, Electromagnetic compatibility (EMC)--Testing and measurement techniques--Flickermeter--Functional and design specificationsIEC 61000-4-15:2010 is adopted by this standard. IEC 61000-4-15:2010 gives a functional and design specification for flicker measuring apparatus... Active Standard
1458-2005 - Recommended Practice for the Selection, Field Testing, and Life Expectancy of Molded Case Circuit Breakers for Industrial ApplicationsA recommended procedure for the selection, application, and determination of the remaining life in molded case circuit breaker is provided. Active Standard
1459-2000 - Standard Definitions for the Measurement of Electric Power Quantities under Sinusoidal, Non-Sinusoidal, Balanced, or Unbalanced ConditionsThis is a trial-use standard for definitions used for measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or... Superseded Standard
1459-2010 - Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced ConditionsThis document provides definitions of electric power to quantify the flow of electrical energy in single-phase and three-phase circuits under... Active Standard
1460-1996 - Guide for the Measurement of Quasi-Static Magnetic and Electric FieldsA listing of possible measurement goals related to characterizing quasi-static magnetic and electric fields and possible methods for their... Active Standard
1493-2006 - Guide for the Evaluation of Solvents Used for Cleaning Electrical Cables and AccessoriesTest procedures for evaluating the physical characteristics of cable cleaning solvents and their compatibility with extruded dielectric cable... Active Standard
1511-2004 - Guide for Investigating and Analyzing Power Cable, Joint, and Termination Failures on Systems Rated 5 kV Through 46 kVThis guide applies to the process of investigating, evaluating, and analyzing field failures. This guide covers the overall format for failure... Active Standard
1511.1-2010 - Guide for Investigating and Analyzing Shielded Power Cable Failures on Systems Rated 5 kV Through 46 kVThis guide covers specific methods of failure mode classifications and analysis for shielded power cables rated 5 kV through 46 kV. Active Standard
1521-2003 - Measurement of Video Jitter and WanderA set of metrics and methods to enable consistent measurement of the components of timing interval error in video synchronization signals is... Active Standard
1528-2003 - Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement TechniquesIEEE Std 1528-2003 specifies protocols and test procedures for the measurement of the peak spatial-average SAR induced inside a simplified model... Superseded Standard
1528-2013 - Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement TechniquesProtocols and test procedures are specified for the measurement of the peak spatial-average SAR induced inside a simplified model of the head of... Active Standard
1553-2002 - Voltage Endurance Testing of Form-Wound Coils and Bars for HydrogeneratorsThe test parameters and acceptance criteria for voltage-endurance testing of form-wound bars and coils for use in large hydrogenerators are... Active Standard
1560-2005 - Methods of Measurement of Radio Frequency Power Line Interference Filter in the Range of 100 Hz to 10 GHzUniform methods of measurements of radio-frequency power-line interference filter attenuation performance in the range of 100 Hz to 10 GHz are set... Active Standard
1566-2005 - Performance of Adjustable Speed AC Drives Rated 375 kW and LargerThis standard is applied to ac adjustable speed drive (ASD) systems rated above 375 kW and above 750 V output voltage as used in petrochemical and... Active Standard
1580-2001 - Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating PlatformsRequirements are given for single or multiconductor cables, with or without metal armor and/or jacket, and rated 300 V to 35 kV, intended to be... Superseded Standard
1580-2010 - Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating FacilitiesRequirements are given for single or multiconductor cables, with or without metal armor and/or jacket, and rated 300 V to 35 kV, intended to be... Active Standard
1584-2002 - Guide for Performing Arc Flash Hazard CalculationsThis guide provides techniques for designers and facility operators to apply in determining the arc-flash hazard distance and the incident energy... Active Standard
1584.1-2013 - Guide for the Specification of Scope and Deliverable Requirements for an Arc-Flash Hazard Calculation Study in Accordance with IEEE Std 1584(TM)Guidance for the specification and performance of an arc-flash hazard calculation study, in accordance with the process defined in IEEE Std 1584... Active Standard
1584a-2004 - Guide for Performing Arc-Flash Hazard Calculations--Amendment 1This amendment provides additions and corrections to IEEE Std 1584-2002. Active Standard
1584b-2011 - Guide for Performing Arc-Flash Hazard Calculations--Amendment 2: Changes to Clause 4Techniques for designers and facility operators to apply in determining the arc-flash hazard distance and the incident energy to which employees... Active Standard
1588-2002 - a Precision Clock Synchronization Protocol for Networked Measurement and Control SystemsA protocol to synchronize independent clocks running on separate nodes of a distributed measurement and control system to a high degree of... Superseded Standard
1588-2008 - a Precision Clock Synchronization Protocol for Networked Measurement and Control SystemsA protocol is provided in this standard that enables precise synchronization of clocks in measurement and control systems implemented with... Active Standard
1591.3-2011 - Qualifying Hardware for Helically-Applied Fiber Optic Cable Systems (WRAP Cable)The purpose of this standard is to establish performance and testing specifications for hardware used on WRAP CABLE systems in order to... Active Standard
1594-2008 - Helically Applied Fiber Optic Cable Systems (Wrap Cable) for Use on Overhead Utility LinesThis standard covers an all-dielectric fiber optic (wrap) cable designed to be helically wrapped around a conductor or other messenger on overhead... Active Standard
1610-2007 - Guide for the Application of Faulted Circuit Indicators for 200 / 600 A, Three-phase Underground DistributionThis application guide provides information on what a FCI is designed to do and describes methods for selecting FCIs for three-phase, 200 / 600... Active Standard
1617-2007 - Guide for Detection, Mitigation, and Control of Concentric Neutral Corrosion in Medium-Voltage Underground CablesThis guide provides a summary of the methods for detection, mitigation, and control of concentric neutral corrosion in medium-voltage, unjacketed,... Active Standard
1624-2008 - Organizational Reliability CapabilityOrganizational reliability capability and the identification of the criteria for assessing the reliability capability of an organization are defined. Active Standard
1631-2008 - Recommended Practice for Measurement of 8-VSB Digital Television Transmission Mask Compliance for the USAThis recommended practice provides a standardized body of theory, techniques, and procedures for measuring the spectral characteristics of 8-VSB... Active Standard
1637-2010 - Guide to Select Terminations for Shielded Alternating-Current Power Cable Rated 5 kV - 46 kVA step-by-step process for selecting an appropriate termination that is commensurate with a particular shielded power cable design is provided in... Active Standard
1641-2004 - Signal and Test DefinitionThis standard provides the means to define and describe signals used in testing. It also provides a set of common basic signals, mathematically... Superseded Standard
1641-2010 - Signal and Test DefinitionThis standard provides the means to define and describe signals used in testing. It also provides a set of common basic signals, built upon formal... Active Standard
1650-2005 - Standard Test Methods for Measurement of Electrical Properties of Carbon NanotubesRecommended methods and standardized reporting practices for electrical characterization of carbon nanotubes (CNTs) are covered. Due to the nature... Active Standard
1652-2008 - the Application of Free Field Acoustic Reference to Telephony MeasurementsThis standard provides the techniques and rationale for referencing acoustic telephony measurements to the free field. It applies to ear related... Active Standard
1662-2008 - Guide for the Design and Application of Power Electronics in Electrical Power Systems on ShipsThis guide applies to power electronics components and systems on ships and similar applications. It summarizes current electrical engineering... Active Standard
1682-2011 - Qualifying Fiber Optic Cables, Connections, and Optical Fiber Splices for Use in Safety Systems in Nuclear Power Generating StationsThis standard provides general requirements, directions, and methods for qualifying fiber optic cables, connections, and optical fiber splices for... Active Standard
1683-2014 - Guide for Motor Control Centers Rated up to and including 600 V AC or 1000 V DC with Recommendations Intended to Help Reduce Electrical HazardsFunctional design recommendations and field practices for motor control centers (single- and three-phase 50 Hz and 60 Hz and dc) are provided in... Active Standard
1709-2010 - Recommended Practice for 1 kV to 35 kV Medium-Voltage DC Power Systems on ShipsGuidelines to specify, procure, design, manufacture and develop manuals, safety procedures, practices and procedures for effective maintenance of... Active Standard
1716-2014 - Approved Draft Recommended Practice for Managing Natural Disaster Impact on key electrical systems and installations in Petroleum and Chemical FacilitiesThis document provides recommendations and guidelines for managing natural disaster impact on key electrical facilities and systems in petroleum... Active Standard
1717-2012 - Testing Circuit Integrity Cables Using a Hydrocarbon Pool Fire Test ProtocolStandardization of circuit integrity cable testing is beneficial to cable manufacturers, distributors, and users. Uniform procedures, consistent,... Active Standard
1718-2012 - Guide for Temperature Monitoring of Cable SystemsThe various existing technologies that are used or can be used to monitor the temperature of cable systems are reviewed in this guide. The... Active Standard
1720-2012 - Recommended Practice for Near-Field Antenna MeasurementsNear-field test practices for the measurement of antenna properties are described in this document and near-field measurement practices for the... Active Standard
1727-2013 - Guide for Working Procedures on Underground Transmission Circuits with Induced VoltageInduced voltage working procedures for underground transmission circuits are established in this guide. A transmission circuit when de-energized... Active Standard
1775-2010 - Power Line Communication Equipment--Electromagnetic Compatibility (EMC) Requirements--Testing and Measurement MethodsElectromagnetic compatibility (EMC) criteria and consensus test and measurements procedures for broadband over power line (BPL) communication... Active Standard
1776-2008 - Recommended Practice for Thermal Evaluation of Unsealed or Sealed Insulation Systems for AC Electric Machinery Employing Form-Wound Pre-Insulated Stator Coils for Machines Rated 15 000 V and BelowA test procedure (Combination of IEEE Std 275™-1992 and IEEE Std 429™-1994) for comparing two or more insulation systems in accordance with their... Active Standard
1793-2012 - Guide for Planning and Designing Transition Facilities between Overhead and Underground Transmission LinesCareful consideration of the physical and electrical characteristics of overhead lines and transmission cables are necessary in designing a... Active Standard
1816-2013 - Guide for Preparation Techniques of Extruded Dielectric, Shielded Cables Rated 2.5 kV through 46 kV and the Installation of Mating AccessoriesAccepted best industry practices for the preparation of extruded dielectric shielded medium voltage cables rated 2.5 kV through 46 kV for the... Active Standard
1826-2012 - Power Electronics Open System Interfaces in Zonal Electrical Distribution Systems Rated Above 100 kWOpen system interfaces for high power electronics equipment used in zonal electrical distribution systems rated above 100 kW are identified in... Active Standard
2003-1997 - Requirements and Guidelines for Test Methods Specifications and Test Method Implementations for Measuring Conformance to POSIX StandardsThis standard defines the requirements and guidelines for test method specifications and test method implementations for measuring conformance to... Withdrawn Standard
2003.1-1992 - Test Methods for Measuring Conformance to POSIX(R)--Part1: System InterfacesIEEE Std 2003.1-1992 provides a definition of the requirements placed upon providers of POSIX test methods for POSIX.1 (IEEE Std 10031-1990; ISO... Withdrawn Standard
2003.1b-2000 - Test Methods Specifications for Measuring Conformance to POSIX(R) - Part 1: System Application Program Interface (API) -Amendment 1: Realtime Extension [C Language]This standard defines the test method specifications for IEEE Std 1003.1b-1993 [based on the document corresponding to the merger of IEEE Std 1003... Withdrawn Standard
2003.2-1997 - Test Methods for Measuring Conformance to POSIX(R) - Part II: Shell and UtilitiesA definition of the requirements placed upon providers of aPOSIXConformance Test Suite for thePOSIX.2 standard (ISO/IEC9945-2:1993,IEEE/ANSIStd.... Withdrawn Standard
3001.5-2013 - Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power SystemsThe selection and application of power distribution apparatus used in industrial and commercial power systems are covered in this recommended... Active Standard
3001.8-2013 - Recommended Practice for the Instrumentation and Metering of Industrial and Commercial Power SystemsThis recommended practice covers the instrumentation and metering of industrial and commercial power systems. It describes the importance of... Active Standard
3004.1-2013 - Recommended Practice for the Application of Instrument Transformers in Industrial and Commercial Power SystemsThe selection and application of instrument transformers used in industrial and commercial power systems are covered in this recommended practice. Active Standard
3006.7-2013 - Recommended Practice for Determining the Reliability of 7x24 Continuous Power Systems in Industrial and Commercial FacilitiesMethods for determining the reliability of 7×24 continuous power systems in industrial and commercial facilities are described in this recommended... Active Standard
3006.9-2013 - Recommended Practice for Collecting Data for Use in Reliability, Availability, and Maintainability Assessments of Industrial and Commercial Power SystemsCollection of data for use in reliability, availability, and maintainability assessments of industrial and commercial power systems is described... Active Standard
3007.1-2010 - Recommended Practice for the Operation and Management of Industrial and Commercial Power SystemsRecommended practices for the numerous personnel who are responsible for safely operating and managing industrial and commercial electric power... Active Standard
3007.2-2010 - Recommended Practice for the Maintenance of Industrial and Commercial Power SystemsThis recommended practice covers the maintenance of industrial and commercial power systems. It covers the fundamentals of electrical equipment... Active Standard
3007.3-2012 - Recommended Practice for Electrical Safety in Industrial and Commercial Power SystemsAll aspects of electrical safety in industrial and commercial power systems are covered. This recommended practice provides personnel with... Active Standard
14143.1-2000 - Adoption of ISO/IEC 14143-1:1998 Information Technology - Software Measurement - Functional Size Measurement - Part 1: Definition of ConceptsImplementation notes that relate to the IEEE interpretation of the ISO/IEC 14143-1:1998 standard are described. Withdrawn Standard
14515-1:2000 /Amd.1-2003 - ISO/IEC Portable Operating System Interface (POSIX(R)) -- Test methods for measuring conformance to POSIX -- Part 1: System interfaces -- Amendment 1: Realtime extension (C Language)This standard defines the test method specifications for IEEE Std 1003.b-1993 (based on the document corresponding to the merger of IEEE Std 1003... Active Standard
14515-2-2003 - ISO/IEC International Portable Operating System Interface (POSIX)--Test methods for measuring conformance to POSIX--Part 2:Shell and utilitiesA definition of the requirements placed upon providers of a POSIX Conformance Test Suite for the POSIX.2 standard (ISO/IEC 9945-2:1993, IEEE/ANSI... Active Standard
15939-2008 - Standard Adoption of ISO/IEC 15939:2007--Systems and Software Engineering--Measurement ProcessA measurement process applicable to system and software engineering and management disciplines is defined by this International Standard. The... Active Standard
61588-2004 - IEC/Precision clock sychronization protocol for networked measurement and control systemsA protocol to synchronize independent clocks running on separate nodes of a distributed measurement and control system to a high degree of... Superseded Standard
61588-2009 - IEC 61588 Ed.2 (Std 1588-2008): Precision Clock Synchronization Protocol for Networked Measurement and Control SystemsA protocol is provided in this standard that enables precise synchronization of clocks in measurement and control systems implemented with... Active Standard
61691-1-1-2004 - IEC 61691-1-1 Ed.1 (Std 1076(TM)-2002): Behavioural Languages - Part 1-1: VHDL Language Reference ManualVHSIC Hardware Description Language (VHDL) is defined. VHDL is a formal notation intended for use in all phases of the creation of electronic... Active Standard
61691-1-1-2011 - Behavioural languages - Part 1-1: VHDL Language Reference ManualAdoption of IEEE Std 1076-2008. VHSIC Hardware Description Language (VHDL) is defined. VHDL is a formal notation intended for use in all phases of... Active Standard
61691-4-2004 - IEC 61691-4 Ed.1 (Std 1364(TM)-2001): Behavioural Languages - Part 4: Verilog(C) Hardware Description LanguageThe Verilog Hardware Description Language (HDL) is defined in this standard. Verilog HDL is a formal notation intended for use in all phases of... Withdrawn Standard
61691-5-2004 - IEC 61691-5 Ed.1 (Std 1076.4(TM)-2000): Behavioural Languages - Part 5: Standard VITAL ASIC (Application Specific Integrated Circuit) Modeling SpecificationThe VITAL (VHDL Initiative Towards ASIC Libraries) ASIC Modeling Specication is defined in this standard. This modeling specication defines a... Active Standard
61691-6-2009 - Behavioural languages - Part 6: VHDL Analog and Mixed-Signal ExtensionsThis standard defines the IEEE 1076.1 language, a hardware description language for the description and the simulation of analog, digital, and... Active Standard
61691-7-2009 - Behavioural languages - Part 7: SystemC Language Reference ManualSystemC is defined in this standard. SystemC is an ANSI standard C++ class library for system and hardware design for use by designers and... Active Standard
62271-37-082-2012 - High-voltage switchgear and controlgear -Part 37-082: Standard practice for the measurement of sound pressure levels on alternating current circuit-breakersThis standard provides methods for the measurement of sound pressure level produced by outdoor alternating current circuit-breakers in a free... Active Standard
62624-2009 - Test methods for measurement of electrical properties of carbon nanotubesAdoption of IEEE Std 1650-2005. Recommended methods and standardized reporting practices for electrical characterization of carbon nanotubes (CNTs... Active Standard
80005-1-2012 - IEC/ISO/Utility Connections in Port--Part 1: High Voltage Shore Connection (HVSC) Systems--General requirementsIEC/ISO/IEEE 80005-1-2012 describes high voltage shore connection (HVSC) systems, on board the ship and on shore, to supply the ship with... Active Standard
C2-1981 - National Electrical Safety CodeThis IEEE Standards product is part of the NESC family. Superseded Standard
C2-1984 - National Electrical Safety CodeBasic provisions are set forth for safeguarding of persons from hazards arising from the installation, operation, or maintenance of (1) conductors... Superseded Standard
C2-1987 - Tables from the National Electrical Safety CodeThis IEEE Standards product is part of the NESC family. Withdrawn Standard
C2-1987 - National Electrical Safety CodeBasic provisions are set forth for safeguarding of persons from hazards arising from the installation, operation, or maintenance of (1) conductors... Superseded Standard
C2-1990 - Tables from the National Electrical Safety Code(R) (NESC)This IEEE Standards product is part of the family on NESCs. The tables from the 1990 edition of the National Electrical Safety Code are presented... Withdrawn Standard
C2-1990 - National Electric Safety CodeThis standard covers basic provisions for safeguarding of persons form hazards arising from the installation, operation, or maintenance of 1)... Active Standard
C2-2002 - National Electrical Safety Code 2002 EditionThis standard covers basic provisions for safeguarding of persons from hazards arising from the installation, operation, or maintenance of 1)... Active Standard
C2-2012 - National Electrical Safety Code (NESC) Handbook, Seventh EditionThe 2012 NESC(R) Handbook, Seventh Edition, edited by Allen Clapp, is an essential companion to the Code. It gives users insight into what lies... Active Standard
C2-2012 - 2012 National Electrical Safety Code (NESC)This Code covers basic provisions for safeguarding of persons from hazards arising from the installation, operation, or maintenance of (1)... Active Standard
C37.1-1987 - Standard Definition, Specification, and Analysis of Systems Used for Supervisory Control, Data Acquisition, and Automatic ControlThe standard applies to systems used for monitoring, switching and controlling electric apparatus in unattended or attended substations,... Superseded Standard
C37.1-1994 - Standard Definition, Specification and Analysis of Systems Used for Supervisory Control, Data Acquisition, and Automatic ControlIn this IEEE standard, distributed multi-computer master stations and distributed remote terminal units (RTUs) are introduced. Submaster RTUs used... Superseded Standard
C37.1-2007 - SCADA and Automation SystemsThe requirements for SCADA and automation systems in substations are defined. This standard defines the process of substation integration as the... Active Standard
C37.2-1987 - Standard Electrical Power System Device Function NumbersThis standard applies tot he definition and application of function numbers for devices used in electrical substations and generating plants and... Superseded Standard
C37.2-1991 - Standard Electrical Power System Device Function NumbersA device function number, with an appropriate prefix and suffix where necessary, is used to identify the function of each device in all types of... Superseded Standard
C37.2-1996 - Standard Electrical Power System Device Function Numbers and Contact DesignationsThe definition and application of function numbers for devices used in electrical substations and generating plants and in installations of power... Superseded Standard
C37.2-2008 - Standard Electrical Power System Device Function Numbers, Acronyms, and Contact DesignationsThe definition and application of function numbers and acronyms for devices and functions used in electrical substations and generating plants and... Active Standard
C37.04-1979 - Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisSuperseded by C37.04-1999 A rating structure for AC high-voltage circuit breakers rated on a symmetrical current basis is established. The rating... Superseded Standard
C37.04-1999 - Standard Rating Structure for AC High-Voltage Circuit BreakersThis standard covers the rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V AC and comprise... Active Standard
C37.04a-2003 - Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis: Amendment 1 Capacitance Current SwitchingThis amendment specifies the capacitance current switching portion of the rating structure for all ac circuit breakers rated above 1000 V,... Active Standard
C37.04g-1986 - Supplement to Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisSupplement to IEEE C37.04-1979. Superseded by C37.04-1999 (SH94774/SS94774). Supplement to IEEE Standard Rating Structure for AC High-Voltage... Superseded Standard
C37.04h-1990 - Supplement to Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisWithdrawn Standard. Withdrawn Date: May 20, 1996. No longer endorsed by the IEEE. Supplement to IEEE Standard Rating Structure for AC High-Voltage... Withdrawn Standard
C37.04i-1991 - Supplement to Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisThis supplement replaces the last paragraph of 5.11.4.2 in C37.04- 1979 and adds a new section, 5.11.4.3, Initial Transient Recovery Voltage. Superseded Standard
C37.06-2009 - AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities for Voltages Above 1000 VThe preferred ratings of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial, and utility... Active Standard
C37.09-1979 - Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisSuperseded The various tests that are made on AC high-voltage circuit breakers are summarized. Accepted methods used in making the tests are... Superseded Standard
C37.09-1999 - Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisThe testing procedures for all high-voltage circuit breakers that include all voltage ratings above 1000 V AC and comprise both indoor and outdoor... Active Standard
C37.09a-1991 - Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisThe required load-current switching capability and life are defined, and load-current switching tests are specified. Superseded Standard
C37.09g-1991 - Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisSuperseded by C37.09-1999. Supplement to IEEE C37.09-1979 Available at no charge Abstract: This supplement to C37.09-1979 adds a paragraph at the... Superseded Standard
C37.010-1979 - Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisAC high-voltage circuit breakers rated in accordance with the methods given in ANSI/IEEE C37.04-1979 and listed in ANSI C37.06-1979 are covered.... Superseded Standard
C37.10-1995 - Guide for Diagnostics and Failure Investigation of Power Circuit BreakersIn this IEEE standard procedures to be used to perform failure investigations of power circuit breakers are recommended. Although the procedure... Superseded Standard
C37.010-1999 - Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisThis guide covers the application of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial and... Active Standard
C37.10-2011 - Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker FailuresPractices and processes to perform, analyze, and report failure investigations of power circuit breakers are provided. Active Standard
C37.10.1-2000 - Guide for the Selection of Monitoring for Circuit BreakersDirection is provided for the selection of monitoring and for diagnostic parameters to be used with high-voltage circuit breakers (i.e., above 100... Active Standard
C37.010b-1985 - Emergency Load Current-Carrying Capability A section on emergency load current-carrying capability is added to IEEE C37.010-1979 as 4.4.4. Superseded Standard
C37.011-1979 - Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisSuperseded by C37.011-1994. Transient recovery voltage requirements for AC high-voltage circuit breakers rated above 1000 V and on a symmetrical... Superseded Standard
C37.011-1994 - Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisProcedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for AC high-voltage circuit breakers rated... Superseded Standard
C37.11-1997 - Standard Requirements for Electrical Control for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisStandard requirements for all types of electrical control circuits for AC high-voltage breakers rated above 1000 V are given. This IEEE Standard... Active Standard
C37.011-2005 - Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit BreakersProcedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated... Superseded Standard
C37.011-2011 - Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit BreakersProcedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated... Active Standard
C37.012-1979 - Application Guide for Capacitance Current Switching for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current BasisThis IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. AC high-voltage circuit breakers rated in... Superseded Standard
C37.012-2005 - Application Guide for Capacitance Current Switching for AC High-Voltage Circuit BreakersGuidance for the application of ac high-voltage circuit breakers for capacitance current switching is provided. The application guide addresses... Superseded Standard
C37.012-2014 - Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 VGuidance for the application of ac high-voltage circuit breakers is provided. The application guide addresses the general theory of capacitance... Active Standard
C37.13-1981 - LV AC PCBs Used in EnclosuresThis standard covers enclosed low-voltage AC power circuit breakers, as follows: (1) stationary or draw-out type of two or three-pole construction... Superseded Standard
C37.013-1989 - AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current BasisThis standard applies to all AC high-voltage generator circuit breakers rated on a symmetrical current basis, with rated maximum voltage 15.8 kV... Superseded Standard
C37.13-1990 - Low-Voltage AC Power Circuit Breakers Used in EnclosuresThe standard covers enclosed low-voltage AC power circuit breakers of the stationary or draw-out type of two or three-pole construction, with one... Superseded Standard
C37.013-1993 - AC High Voltage Generator Circuit Breakers Rated on a Symmetrical Current BasisRatings, performance requirements, and compliance test methods are provided for ac high-voltage generator circuit breakers rated on a symmetrical... Superseded Standard
C37.013-1997 - AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current BasisRatings, performance requirements and compliance test methods are provided for AC high-voltage generator circuit breakers rated on a symmetrical... Active Standard
C37.13-2008 - Low-Voltage AC Power Circuit Breakers Used in EnclosuresThe following enclosed low-voltage ac power circuit breakers are covered in this standard: a) stationary or draw-out type of two-, three-, or four... Active Standard
C37.14-1979 - Low-Voltage DC Power Circuit Breakers Used in EnclosuresThis standard covers enclosed low-voltage DC power circuit breakers of the stationary or drawout type of single- or two-pole construction with one... Superseded Standard
C37.14-1992 - Low-Voltage DC Power Circuit Breakers Used in EnclosuresThis standard covers enclosed low-voltage dc power circuit breakers of the stationary or drawout type of single- or two-pole construction with one... Superseded Standard
C37.14-1999 - Low-Voltage DC Power Circuit Breakers Used in EnclosuresThis standard covers enclosed low-voltage DC power circuit breakers of the stationary or draw-out type of singleor two-pole construction with one... Superseded Standard
C37.14-2002 - Low-Voltage DC Power Circuit Breakers Used in EnclosuresThis standard covers enclosed low-voltage DC power circuit breakers of the stationary or draw-out type of oneor two-pole construction with one or... Active Standard
C37.16-2009 - Preferred Ratings,Related Requirements, and Application Recommendations for Low-Voltage AC (635 V and below)and DC (3200 V and below) Power Circuit BreakersThis standard defines the preferred ratings for low-voltage ac (635 V and below) power circuit breakers, general purpose dc (325 V and below)... Active Standard
C37.17-2012 - Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit BreakersRequirements for direct acting current and voltage protective functions of direct-acting overcurrent electromechanical trip devices, direct-acting... Active Standard
C37.18-1979 - Standard Enclosed Field Discharge Circuit Breakers for Rotating Electric MachineryLow-voltage power circuit breakers that are intended for use in field circuits of apparatus such as generators, motors, synchronous condensers, or... Withdrawn Standard
C37.20.1-1987 - Metal-Enclosed Low-Voltage Power Circuit-Breaker SwitchgearThe standard covers metal-enclosed LV power circuit breaker switchgear assemblies containing such devices as power circuit breakers, interrupting... Superseded Standard
C37.20.1-1993 - Metal-Enclosed Low-Voltage Power Circuit Breaker SwitchgearLow-voltage metal-enclosed switchgear, which can contain either stationary or drawout, manually or electrically operated low-voltage ac or dc... Superseded Standard
C37.20.1-2002 - Metal-Enclosed Low-Voltage Power Circuit Breaker SwitchgearLow-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually or electrically operated low-voltage ac or dc power... Active Standard
C37.20.1a-2005 - Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear---Amendment 1: Short-Time and Short-Circuit Withstand Current Tests---Minimum Areas for Multiple Cable ConnectionsThis amendment revises IEEE Std C37.20.1-2002. Use of "dummy elements," previously allowed for short-circuit tests in 6.2.4 and 6.2.5.2, is... Active Standard
C37.20.2-1987 - Metal-Clad and Station-Type Cubicle SwitchgearThe standard covers metal-clad and station-type cubicle switchgear containing but not limited to such devices as power circuits breakers,... Superseded Standard
C37.20.2-1993 - Metal-Clad and Station-Type Cubicle SwitchgearMetal-enclosed medium voltage switchgear (ME), which can contain either drawout electrically operated circuit breakers or stationary electrically... Superseded Standard
C37.20.2-1999 - Metal-Clad SwitchgearMetal-clad (MC) medium-voltage switchgear that contains drawout electrically operated circuit breakers is covered. MC switchgear is... Active Standard
C37.20.2b-1994 - Supplement to Metal-Clad and Station-Type Cubicle Switchgear: Current Transformers AccuraciesMetal-enclosed medium voltage switchgear (ME), which can contain either drawout electrically operated circuit breakers or stationary electrically... Superseded Standard
C37.20.3-1987 - Metal-Enclosed Interrupter SwitchgearThe standard covers metal-enclosed interrupter switchgear assemblies containing such devices as interrupter/switches, selector switches, power... Superseded Standard
C37.20.3-2001 - Metal-Enclosed Interrupter SwitchgearThis standard covers metal-enclosed interrupter (MEI) switchgear assemblies containing, but not limited to, such devices as interrupter switches;... Superseded Standard
C37.20.3-2013 - Metal-Enclosed Interrupter Switchgear (1 kV–38 kV)Metal-enclosed interrupter (MEI) switchgear assemblies containing, but not limited to, such devices as interrupter switches; selector switches;... Active Standard
C37.20.4-1996 - Trial-Use Indoor AC Switches (1 kV-38 kV) for Use in Metal-Enclosed SwitchgearIndoor ac medium-voltage switches for use in enclosures for application in power circuits at voltages above 1 kV through 38 kV are covered. These... Superseded Standard
C37.20.4-2001 - Indoor AC Switches (1 kV - 38 kV) for Use in Metal-Enclosed SwitchgearIndoor AC medium-voltage switches for use in enclosures for application in power circuits at voltages above 1 kV through 38 kV are covered. These... Superseded Standard
C37.20.4-2013 - Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed SwitchgearIndoor ac medium-voltage switches for use in enclosures for application in power circuits at voltages above 1 kV through 38 kV are covered in this... Active Standard
C37.20.6-1997 - 4.76 kV to 38 kV Rated Grounding and Testing Devices Used in EnclosuresDrawout type grounding and testing (G&T) devices for use in medium-voltage metal-clad switchgear rated above 4.76 kV through 38 kV are covered... Superseded Standard
C37.20.6-2007 - 4.76 kV to 38 kV Rated Ground and Test Devices Used in EnclosuresDrawout-type ground and test devices for use in medium-voltage metal-clad switchgear rated 4.76 kV through 38 kV are covered. The description,... Superseded Standard
C37.20.6-2007 - 4.76 kV to 38 kV Rated Ground and Test Devices Used in EnclosuresDrawout-type ground and test devices for use in medium-voltage metal-clad switchgear rated 4.76 kV through 38 kV are covered. The description,... Active Standard
C37.20.7-2001 - Guide for Testing Medium-Voltage Metal-Enclosed Switchgear for Internal Arcing FaultsA procedure for testing, evaluating the performance of medium-voltage metal-enclosed switchgear for internal arcing faults is covered in this... Superseded Standard
C37.20.7-2007 - Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing FaultsRevision of IEEE Std C37.20.7-2001. A procedure for testing and evaluating the performance of metal-enclosed switchgear for internal arcing faults... Active Standard
C37.21-1985 - Control SwitchboardsThe standard outlined, draft ANSI/IEEE C37.21-1985, covers ratings, construction, and testing of dead-front control switchboards containing but... Superseded Standard
C37.21-2005 - Control SwitchboardsThis standard covers ratings, construction, and testing of dead-front control switchboards containing, but not limited to, devices such as... Active Standard
C37.23-1987 - Guide for Metal-Enclosed Bus and Calculating Losses in Isolated-Phase BusAssemblies of metal-enclosed conductors along with associated interconnections, enclosures and supporting structures are considered. When switches... Superseded Standard
C37.23-2003 - Metal-Enclosed BusMetal-enclosed (ME) bus assemblies for indoor and outdoor use are covered in this standard. The types of assemblies covered are nonsegregated... Active Standard
C37.24-1986 - Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed SwitchgearSuperseded by C37.24-2003. This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. This standard... Superseded Standard
C37.24-2003 - Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed SwitchgearThis guide provides information to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear including metal... Active Standard
C37.26-1972 - Standard Guide for Methods of Power-Factor Measurement for Low-Voltage Inductive Test CircuitsSuperseded by C37.26-2003. Methods used to measure the power factor in low-voltage test circuits are covered. Since the power factor measurement... Superseded Standard
C37.26-2003 - Guide for Methods of Power-Factor Measurement for Low-Voltage Inductive Test CircuitsThis guide provides methods for determining the value of power factor for inductive lowvoltage (1000 volts ac and below) test circuits. These... Active Standard
C37.29-1981 - Low-Voltage AC Power Circuit Protectors Used in EnclosuresWithdrawn Standard. Withdrawn Date: Feb 06, 2006. This standard covers enclosed low-voltage ac power circuit protectors that are manually operated... Withdrawn Standard
C37.30-1971 - American National Standard Definitions and Requirements for High-Voltage Air Switches, Insulators, and Bus SupportsSuperseded. Required ratings and constructional requirements for switches above 1000 V are described. Superseded Standard
C37.30-1992 - Standard Requirements for High Voltage Air SwitchesIn this standard, requirements for all high-voltage enclosed indoor or outdoor and nonenclosed indoor or outdoor air switches rated in excess of... Superseded Standard
C37.30-1997 - Standard Requirements for High Voltage SwitchesRequired ratings and constructional requirements for switches above 1000 V are described. Superseded Standard
C37.34-1994 - Standard Test Code for High-Voltage Air SwitchesIn this IEEE Standard design test requirements for all high-voltage enclosed indoor and outdoor and non enclosed indoor and outdoor air switches... Superseded Standard
C37.35-1976 - Guide for the Application, Installation, Operation, and Maintenance of High-Voltage Air Disconnecting and Load Interrupter SwitchesSuperseded Suggestions on application, installation, operation, and maintenance are presented as an aid to obtaining satisfactory performance from... Superseded Standard
C37.35-1995 - Guide for the Application, Installation, Operation, and Maintenance of High-Voltage Air Disconnecting and Interrupter SwitchesThis IEEE guide presents suggestions on application, installation, operation, and maintenance as an aid to obtaining satisfactory performance of... Superseded Standard
C37.40-1981 - American National Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesThe standard applies to high-voltage fuses (above 600 V), distribution enclosed single-pole air switches and fuse disconnecting switches.... Superseded Standard
C37.40-1993 - Standard Service Conditions and Definitions for High Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches & AccessoriesService conditions and definitions for high-voltage fuses (above 1,000 V), distribution enclosed single-pole air switches, fuse disconnecting... Superseded Standard
C37.40-2003 - Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesService conditions and definitions for high-voltage fuses (above 1000 V), distribution enclosed single-pole air switches, fuse disconnecting... Active Standard
C37.41-1988 - Standard Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesThis standard applies to tests for high-voltage fuses (above 600 V), distribution enclosed single-pole air switches, fuse disconnecting switches,... Superseded Standard
C37.41-1994 - Standard Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches and AccessoriesIn this IEEE Standard required procedures for performing design tests for high-voltage distribution-class and power-class fuses, as well as for... Superseded Standard
C37.41-2000 - Standard Design Tests For High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesRequired procedures for performing design tests for high-voltage distribution class and power-class fuses, as well as for fuse-disconnecting... Superseded Standard
C37.45-2007 - Standard Specifications for High Voltage Distribution Class Enclosed Single-Pole Air Switches with Rated Voltages from 1 through 8.3 kVIEEE specifications for high-voltage (above 1000 V) distribution class enclosed single-pole air switches and associated accessories with rated... Active Standard
C37.46-2000 - Amerian National High Voltage Expulsion and Current-Limiting Type Power Class Fuses and Fuse Disconnecting SwitchesThis standard establishes specifications for high voltage (above 1000 volts) expulsion and current-limiting type power class fuses, and... Withdrawn Standard
C37.46-2010 - Standard Specifications for High-Voltage (>1000 V) Expulsion and Current-Limiting Power Class Fuses and Fuse Disconnecting SwitchesSpecifications for high-voltage (above 1000 V) expulsion and current-limiting type power class fuses, fuse disconnecting switches, their... Active Standard
C37.47-2011 - Standard Specifications for High-Voltage (>1000 V) Distribution Class Current-Limiting Type Fuses and Fuse Disconnecting SwitchesSpecifications for high-voltage (>1000 V) distribution class current-limiting fuses and fuse disconnecting switches, and associated accessories... Active Standard
C37.48-1987 - Guide for Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesThe guide applies to high-voltage fuses (above 600 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and... Superseded Standard
C37.48-1997 - Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesInformation on the application, operation, and maintenance of high-voltage fuses (above 1000 V), distribution enclosed single-pole air switches,... Superseded Standard
C37.48-2005 - Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and AccessoriesInformation on the application, operation and maintenance of high-voltage fuses (above 1000 V and through 169 W), distribution enclosed single... Active Standard
C37.61-1973 - Standard Guide for the Application, Operation, and Maintenance of Automatic Circuit ReclosersInformation on the selection, application, operation, and maintenance of single-or multi-pole AC automatic circuit reclosers is provided. The... Withdrawn Standard
C37.082-1982 - Standard Methods for the Measurement of Sound Pressure Levels of AC Power Circuit BreakersGuidelines for uniform measurement and reporting of sound produced by AC power circuit breakers are established. The methods are intended for... Superseded Standard
C37.90-1989 - Relays and Relay Systems Associated with Electric Power ApparatusThis standard applies only to relays and relay systems used to protect and control power apparatus. The purpose of this standard is to specify... Superseded Standard
C37.90-2005 - Relays and Relay Systems Associated with Electric Power ApparatusService conditions, electrical ratings, thermal ratings, and testing requirements are defined for relays and relay systems used to protect and... Active Standard
C37.90.1-1974 - Standard Surge Withstand Capability Test For Proctective Relays and Relay SystemsThe development of the transistor resulted in semiconductor components being used in both relay and communication equipment. However, it was... Superseded Standard
C37.90.1-1989 - Standard Surge Withstand Capability (SWC) Tests for Protective Relays and Relay SystemsThese surge withstand capability (SWC) tests are design tests intended for protective relays and relay systems, including those incorporating... Superseded Standard
C37.90.1-2002 - Standard Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power ApparatusTwo types of design tests for relays and relay systems that relate to the immunity of this equipment to repetitive electrical transients are... Superseded Standard
C37.90.1-2012 - Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power ApparatusTwo types of design tests for relays and relay systems that relate to the immunity of this equipment to repetitive electrical transients are... Active Standard
C37.90.2-1987 - Trial-Use Standard Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from TransceiversEstablishes a common reference and test procedure for evaluating the performance of static protective and control relays used in electric power... Superseded Standard
C37.90.2-1995 - Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from TransceiversA design test to evaluate the susceptibility of protective relays to single-frequency electromagnetic fields in the radio frequency domain, such... Superseded Standard
C37.90.2-2004 - Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from TransceiversDesign tests for relays and relay systems that relate to the immunity of this equipment to Radiated Electromagnetic Interference from Transceivers... Active Standard
C37.90.3-2001 - Standard Electrostatic Discharge Tests for Protective RelaysThis standard describes test procedure, test point selection, test level, and acceptance criteria for repeatable electrostatic discharge immunity... Active Standard
C37.91-2000 - Guide for Protective Relay Applications to Power TransformersThe protection of power transformers is covered; various electrical protection schemes are explored; and guidelines are given for the application... Superseded Standard
C37.91-2008 - Guide for Protecting Power TransformersThis guide is intended to provide protection engineers and other readers with guidelines for protecting three-phase power transformers of more... Active Standard
C37.95-1989 - Guide for Protective Relaying of Utility-Consumer InterconnectionsThis report contains information on a number of different protective relaying practices for the utility-consumer interconnection. It is intended... Superseded Standard
C37.95-2002 - Guide for Protective Relaying of Utility-Consumer InterconnectionsProtective relay applications involving electric service to consumers that requires a transformation between the utility's supply voltage and the... Superseded Standard
C37.95-2014 - Guide for Protective Relaying of Utility-Consumer InterconnectionsDescribed in this guide are protective relay applications involving electric service to consumers that requires a transformation between the... Active Standard
C37.96-1988 - Guide for AC Motor ProtectionThis IEEE guide for the relay protection of squirrel-cage and wound-rotor induction motors and synchronous motors presents a review of the... Withdrawn Standard
C37.96-2000 - Guide for AC Motor ProtectionGenerally accepted methods of protection for AC motors are provided. This guide identifies and summarizes the functions necessary for adequate... Superseded Standard
C37.96-2012 - Guide for AC Motor ProtectionGenerally accepted methods of protection for ac motors are provided. The functions necessary for adequate protection of motors based on type, size... Active Standard
C37.97-1979 - Guide for Protective Relay Applications to Power System BusesA bus is a critical element of a power systems, as it is the point of convergence of many circuits-transmission, generation, or loads. Factors... Withdrawn Standard
C37.99-1980 - Guide for Protection of Shunt Capacitor BanksThis guide has been prepared to assist in the effective application of relays and other devices for the protection of shunt capacitors used in... Superseded Standard
C37.99-1990 - Guide for the Protection of Shunt Capacitor BanksThis guide has been prepared to assist in the effective application of relays and other devices for the protection of shunt capacitors used in... Superseded Standard
C37.99-2000 - Guide for the Protection of Shunt Capacitor BanksThe protection of shunt power capacitor, filter banks are covered. Guidelines for reliable applications of protection methods intended for use in... Superseded Standard
C37.99-2012 - Guide for the Protection of Shunt Capacitor BanksThis guide applies to the protection of shunt power capacitor banks and filter capacitor banks. Included are guidelines for reliable applications... Active Standard
C37.100-1992 - Standard Definitions for Power SwitchgearIn this standard, terms that encompass the products with the scope of the C37 project are defined. These include power switchgear for switching,... Active Standard
C37.100-1992 - standard definitions for power switchgearIn this standard, terms that encompass the products with the scope of the C37 project are defined. These include power switchgear for switching,... Active Standard
C37.100d-1991 - Supplement to C37.100-1981, Standard Definitions for Power SwitchgearSupplement to IEEE C37.100-1981. Add definition "Initial Transient Recovery Voltage". Terms that encompass the products with the scope of the C37... Superseded Standard
C37.101-1985 - Guide for Generator Ground ProtectionGuidance in the application of relays and relaying schemes for protection against stator ground faults on high-impedance grounded generators is... Superseded Standard
C37.101-1993 - Guide for Generator Ground ProtectionGuidance in the application of relays and relaying schemes for protection against stator ground faults on high-impedance grounded generators is... Superseded Standard
C37.101-2006 - Guide for Generator Ground ProtectionThe guide is intended to assist protection engineers in applying relays and relaying schemes for protection against stator ground faults on... Active Standard
C37.102-1987 - Guide for AC Generator ProtectionThe guide for the relay protection of synchronous generators presents a review of the generally accepted forms of protection for the generator and... Superseded Standard
C37.102-1995 - Guide for AC Generator ProtectionIn this IEEE standard a review of the generally accepted forms of relay protection for the synchronous generator and its excitation system is... Superseded Standard
C37.102-2007 - Guide for AC Generator ProtectionA review of the generally accepted forms of relay protection for the synchronous generator and its excitation system is presented. This guide is... Active Standard
C37.103-1990 - Guide for Differential and Polarizing Relay Circuit TestingThe following topics were dealt with: IEEE C37.103-1990, IEEE Guide for Differential and Polarizing Relay Circuit Testing, covers the testing and... Withdrawn Standard
C37.103-2004 - Guide for Differential and Polarizing Relay Circuit TestingThe issues concerning testing and verification of the correctness of differential and polarizing circuits are described and discussed in this... Active Standard
C37.108-1989 - Guide for the Protection of Network TransformersNetwork transformer vaults are fire retardant enclosures within buildings or adjacent to them that contain two or more power transformers. These... Superseded Standard
C37.108-2002 - Guide for the Protection of Network TransformersGuidelines for the application of network protectors are established. The use of network transformers and protectors with distributed resources is... Active Standard
C37.111-1991 - Standard Common Format for Transient Data Exchange (COMTRADE) for Power SystemsIn this standard a common format for the data files and exchange medium needed for the interchange of various types of fault, test, or simulation... Superseded Standard
C37.111-1999 - Standard Common Format for Transient Data Exchange (COMTRADE) for Power SystemsA common format for data files and exchange medium used for the interchange of various types of fault, test, or simulation data for electrical... Superseded Standard
C37.111-2013 - /IEC Measuring relays and protection equipment – Part 24: Common format for transient data exchange (COMTRADE) for power systemsAlso known as IEC 60255-24 Ed.2, this standard defines a format for files containing transient waveform and event data collected from power... Active Standard
C37.118.1-2011 - Synchrophasor Measurements for Power SystemsSynchronized phasor (synchrophasor) measurements for power systems are presented. This standard defines synchrophasors, frequency, and rate of... Active Standard
C37.118.1a-2014 - Synchrophasor Measurements for Power Systems -- Amendment 1: Modification of Selected Performance RequirementsModifications in this amendment include some performance requirements with related text updates to correct inconsistencies and remove limitations... Active Standard
C37.122.5-2013 - Guide for Moisture Measurement and Control in SF6 Gas-Insulated EquipmentGuidelines for moisture level measurement, moisture data interpretation, and moisture control in gas-insulated switchgear (GIS) are provided. Active Standard
C37.242-2013 - Guide for Synchronization, Calibration, Testing, and Installation of Phasor Measurement Units (PMUs) for Power System Protection and ControlGuidance for synchronization, calibration, testing, and installation of phasor measurement units (PMUs) applied in power systems is provided. The... Active Standard
C37.301-2009 - High-Voltage Switchgear (Above 1000 V) Test Techniques--Partial Discharge MeasurementsThis standard adopts IEC 60270:2000 and defines methods of measuring partial discharges that may occur in energized power switchgear apparatus, in... Active Standard
C50.12-2005 - Salient-Pole 50 Hz and 60 Hz Synchronous Generators and Generator/Motors for Hydraulic Turbine Applications Rated 5 MVA and AboveThe requirements in this standard apply to all types of 50 Hz and 60 Hz salient-pole synchronous generators and generator/motors rated 5 MVA and... Active Standard
C50.13-1977 - American National Standard Requirements for Cylindrical-Rotor Synchronous GeneratorsRequirements for 60-Hz cylindrical-rotor synchronous generators, except those covered in standard C50.14-1977, are set forth. The standard covers... Superseded Standard
C50.13-2005 - Cylindrical-Rotor 50 Hz and 60 Hz Synchronous Generators Rated 10 MVA and AboveThe requirements in this standard are applied to 50 Hz and 60 Hz, two-pole and fourpole, cylindrical-rotor synchronous generators driven by steam... Superseded Standard
C50.13-2014 - Cylindrical-Rotor 50 Hz and 60 Hz Synchronous Generators Rated 10 MVA and AboveThe requirements in this standard are applied to 50 Hz and 60 Hz, two-pole and four pole, cylindrical-rotor synchronous generators driven by steam... Active Standard
C50.14-1977 - American National Standard Requirements for Combustion Gas Turbine Driven Cylindrical Rotor Synchronous GeneratorsThe requirements in this standard apply to 60 Hz open-ventilated air-cooled cylindrical rotor synchronous generators rated 10,000 kVA and above.... Active Standard
C57.12.00-1987 - Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating TransformersThis standard is a basis for the establishment of performance, limited electrical and mechanical interchangeability, and safety requirements of... Superseded Standard
C57.12.00-1993 - Standard General Requirements for Liquid-Immersed Distribution, Power and Regulating TransformersElectrical, mechanical, and safety requirements are set forth for liquid-immersed distribution and power transformers, and autotransformers and... Superseded Standard
C57.12.00-2000 - Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating TransformersElectrical, mechanical, and safety requirements are set forth for liquid-immersed distri-bution and power transformers, and autotransformers and... Superseded Standard
C57.12.00-2006 - Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating TransformersElectrical, mechanical, and safety requirements are set forth for liquid-immersed distribution and power transformers, and autotransformers and... Superseded Standard
C57.12.00-2010 - General Requirements for Liquid-Immersed Distribution, Power, and Regulating TransformersElectrical and mechanical requirements for liquid-immersed distribution and power transformers, and autotransformers and regulating transformers;... Active Standard
C57.12.01-1989 - Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin-Encapsulated WindingsThis standard describes electrical, mechanical, and safety requirements of ventilated, nonventilated, and sealed dry-type distribution and power... Withdrawn Standard
C57.12.01-1998 - Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated WindingsElectrical, mechanical and safety requirements of ventilated, nonventilated and sealed dry-type distribution and power transformers or... Superseded Standard
C57.12.01-2005 - Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated WindingsElectrical, mechanical, and safety requirements of ventilated, non-ventilated, and sealed dry-type distribution and power transformers or... Active Standard
C57.12.10-2010 - Standard Requirements for Liquid-Immersed Power TransformersThis standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance,... Active Standard
C57.12.20-1997 - American National Transformers - Standard for Overhead Type Distribution Transformers, 500 kVA and Smaller: High Voltage 34500 Volts and Below: Low Voltage, 7970/13800Y Volts and BelowSuperseded by IEEE Std C57.12.20-2005.This standard covers certain electrical, dimensional, and mechanical characteristics and takes into... Superseded Standard
C57.12.20-2005 - Overhead Type Distribution Transformers, 500 kVA and Smaller: High Voltage, 34500 Volts and Below; Low Voltage, 7970/13800Y Volts and BelowThis standard covers certain electrical, dimensional, and mechanical characteristics and safety features of singleand three-phase, 60 Hz, mineral... Superseded Standard
C57.12.20-2011 - Overhead-Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34 500 V and Below; Low Voltage, 7970/13 800Y V and BelowCertain electrical, dimensional, and mechanical characteristics and safety features of single- and three-phase, 60 Hz, mineral-oil-immersed, self... Active Standard
C57.12.23-2002 - Underground Type, Self-Cooled, Single-Phase, Distribution Transformers with Separable Insulated High-Voltage Connectors; High Voltage 25000 V and Below; Low Voltage 600 V and Below; 167 kVA and SmallerElectrical, dimensional, and mechanical characteristics and certain safety features of single-phase, 60 Hz, mineral-oil-immersed, self-cooled,... Superseded Standard
C57.12.23-2009 - Submersible Single-Phase Transformers: 167 kVA and Smaller; High Voltage 25 000 V and Below; Low Voltage 600 V and BelowElectrical, dimensional, and mechanical characteristics and certain safety features of single-phase, 60 Hz, liquid-immersed, self-cooled,... Active Standard
C57.12.24-2009 - Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 Volts and Below; Low Voltage, 600 Volts and BelowThis standard is intended for use as a basis for establishing the performance, electrical and mechanical interchangeability, and safety of the... Active Standard
C57.12.40-2006 - Requirements for Secondary Network Transformers, Subway and Vault Types (Liquid-Immersed)This standard is intended for use as a basis for establishing the performance, interchangeability, and safety of the equipment covered and to... Active Standard
C57.12.40-2011 - Network, Three-Phase Transformers, 2500 kVA and Smaller; High Voltage, 34 500 GrdY/19 920 and Below; Low Voltage, 600 V and Below; Subway and Vault Types (Liquid Immersed)This standard is intended for use as a basis for establishing the performance, interchangeability, and safety of the equipment covered and to... Active Standard
C57.12.44-1994 - Standard Requirements for Secondary Network ProtectorsThe performance, electrical and mechanical interchangeability as well as the safety of the equipment are covered in this IEEE standard. The proper... Superseded Standard
C57.12.44-2000 - Standard Requirements for Secondary Network ProtectorsThe performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment... Superseded Standard
C57.12.44-2005 - Standard Requirements for Secondary Network ProtectorsThe performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment... Superseded Standard
C57.12.44-2014 - Standard Requirements for Secondary Network ProtectorsThe performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment... Active Standard
C57.12.52-2012 - Sealed Dry-Type Power Transformers, 501 kVA and Higher, Three-Phase, with High-Voltage 601 to 34500 Volts, Low-Voltage 208Y/120 to 4160 Volts—General RequirementsCharacteristics relating to performance, limited electrical and mechanical interchangeability, and guidance to assist in the proper selection of... Active Standard
C57.12.58-1991 - Guide for Conducting a Transient Voltage Analysis of a Dry-Type Transformer CoilGeneral recommendations for measuring voltage transients in dry-type distribution and power transformers are provided. Recurrent surge voltage... Active Standard
C57.12.59-1989 - Guide for Dry-Type Transformer Through-Fault Current DurationProtective devices, such as relays and fuses, have well-defined operating characteristics that relate fault magnitude to operating time. It is... Withdrawn Standard
C57.12.59-2001 - Guide for Dry-Type Transformer Through-Fault Current DurationThis guide sets forth recommendations believed essential for the application of overcurrent protective devices that limit the exposure time of dry... Active Standard
C57.12.80-1978 - Standard Terminology for Power and Distribution TransformersThis standard is a compilation of terminology and definitions primarily related to electrical transformers and associated apparatus included... Superseded Standard
C57.12.80-2002 - Standard Terminology for Power and Distribution TransformersThis standard is a compilation of terminology and definitions primarily related to electric power and distribution transformers and associated... Superseded Standard
C57.12.80-2010 - Standard Terminology for Power and Distribution TransformersThis standard is a compilation of terminology and definitions related to electric power and distribution transformers and associated apparatus. It... Active Standard
C57.12.90-1987 - Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short-Circuit Testing of Distribution and Power TransformersThe standard describes methods for performing tests on liquid-immersed distribution, power and regulating transformers. It is intended for use as... Superseded Standard
C57.12.90-1993 - Standard Test Code for Liquid-Immersed Distribution, Power and Regulating Transformers and IEEE Guide for Short-Circuit Testing of Distribution and Power TransformersMethods for performing tests specified in IEEE Std C57.12.00-1993, IEEE Standard General Requirements for Liquid-Immersed Distribution, Power, and... Superseded Standard
C57.12.90-1999 - Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating TransformersMethods for performing tests specified in IEEE Std C57.12.00-1993 and other standards applicable to liquid-immersed distribution, power, and... Superseded Standard
C57.12.90-2006 - Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating TransformersMethods for performing tests specified in IEEE Std C57.12.00™-2006 and other standards applicable to liquid-immersed distribution, power, and... Superseded Standard
C57.12.90-2010 - Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating TransformersMethods for performing tests specified in IEEE Std C57.12.00(TM) and other standards applicable to liquid-immersed distribution, power, and... Active Standard
C57.12.91-1979 - Standard Test Code for Dry-Type Distribution and Power TransformersThis standard describes methods for performing tests specified in ANSI/IEEE C57.12.01-1979, general requirements for dry-type distribution and... Superseded Standard
C57.12.91-1995 - Standard Test Code for Dry-Type Distribution and Power TransformersMethods for performing tests specified in IEEE Std C57.12.01-1989 and other referenced standards applicable to dry-type distribution and power... Superseded Standard
C57.12.91-2001 - Standard Test Code for Dry-Type Distribution and Power TransformersMethods for performing tests specified in IEEE Std C57.12.01-1998 and other referenced standards applicable to dry-type distribution and power... Superseded Standard
C57.12.91-2011 - Standard Test Code for Dry-Type Distribution and Power TransformersThis revision addresses substantive changes to Clause 5, 10 and 11 This revision addresses substantive changes to Clause 5, Clause 10, and Clause... Active Standard
C57.13-1978 - Standard Requirements for Instrument TransformersThis standard covers certain electrical, dimensional, and mechanical characteristics, and takes into consideration certain safety features of... Superseded Standard
C57.13-1993 - Standard Requirements for Instrument TransformersElectrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and... Superseded Standard
C57.13-2008 - Standard Requirements for Instrument TransformersElectrical, dimensional, and mechanical characteristics are covered, taking into consideration certain safety features, for current and... Active Standard
C57.13.1-1981 - Guide for Field Testing of Relaying Current TransformersIn the application of protective relays, the most widely used input quantity is current. A multiplicity of different protective relays either... Superseded Standard
C57.13.1-2006 - Guide for Field Testing of Relaying Current TransformersThis guide describes field test methods that assure that current transformers are connected properly, are of marked ratio and polarity, and are in... Active Standard
C57.13.2-1986 - American National Standard Conformance Test Procedures for Instrument TransformersThe purpose of this standard is to cover conformance test requirements for current and inductively coupled voltage transformers used for... Superseded Standard
C57.13.2-1991 - Standard Conformance Test Procedures for Instrument TransformersConformance test requirements are provided for current and inductively-coupled voltage transformers used for measurement and control functions in... Withdrawn Standard
C57.13.2-2005 - Conformance Test Procedure for Instrument TransformersTest requirements for conducting conformance tests on instrument transformers used on 60 Hz primary systems with voltages from 600 V through 38 kV... Active Standard
C57.21-1981 - Standard Requirements, Terminology, and Test Code for Shunt Reactors Rated Over 500 kVAThis standard applies to all oil-immersed or dry-type, single-phase or three-phase outdoor or indoor shunt reactors rated 501 kVA and larger. It... Superseded Standard
C57.21-1990 - Standard Requirements, Terminology, and Test Code for Shunt Reactors Rated Over 500 kVAAll oil-immersed or dry-type, single-phase or three-phase, outdoor or indoor shunt reactors rated over 500 kVA are covered. Terminology and... Superseded Standard
C57.21-2008 - Standard Requirements, Terminology, and Test Code for Shunt Reactors Rated Over 500 kVAAll oil-immersed or dry-type, single-phase or three-phase, outdoor or indoor shunt reactors rated over 500 kVA are covered. Terminology and... Active Standard
C57.91-1981 - Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Distribution Transformers Rated 500kVA and Less with 65 C or 55 C Average Winding RiseThis guide covers general recommendations for loading 65 degrees C rise mineral-oil-immersed overhead and pad-mounted distribution transformers... Superseded Standard
C57.91-1995 - Guide for Loading Mineral-Oil-Immersed TransformersIn this IEEE standard general recommendations for loading 65/spl deg/C rise mineral-oil-immersed distribution and power transformers are covered.... Superseded Standard
C57.91-2011 - Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage RegulatorsThis guide provides recommendations for loading mineral-oil-immersed transformers and step-voltage regulators with insulation systems rated for a... Active Standard
C57.92-1981 - Guide for Loading Mineral-Oil-Immersed Power Transformers Up to and Including 100 MVA with 55 C or 65 C Average Winding RiseThis guide covers general recommendations for loading mineral-oil-immersed power transformers, manufactured in accordance with ANSI C57.12.10-1976... Withdrawn Standard
C57.94-1982 - Recommended Practice for Installation, Application, Operation, and Maintenance of Dry-Type General Purpose Distribution and Power TransformersThis recommended practice covers general recommendations for the application, installation, operation and maintenance of single and polyphase dry... Active Standard
C57.96-1989 - Guide for Loading Dry-Type Distribution and Power TransformersThe guide covers general recommendations for the loading of dry-type distribution and power transformers that have 80 degrees C, 115 degrees C,... Superseded Standard
C57.96-1999 - Guide for Loading Dry-Type Distribution and Power TransformersGeneral recommendations for the loading of dry-type distribution and power transformers that have 80/spl deg/C, 115/spl deg/C, and 150/spl deg/C... Superseded Standard
C57.96-2013 - Guide for Loading Dry-Type Distribution and Power TransformersGeneral recommendations for the loading of dry-type distribution and power transformers installed in ventilated, non-ventilated, and sealed type... Active Standard
C57.100-1986 - Standard Test Procedure for Thermal Evaluation of Oil-Immersed Distribution TransformersThe object of this test procedure is to establish a uniform method for investigating the effect of operating temperature on the life expectancy of... Superseded Standard
C57.100-1999 - Standard Test Procedure for Thermal Evaluation of Liquid-Immersed Distribution and Power TransformersA test procedure is established to provide a uniform method for investigating the effect of operating temperature on the life expectancy of liquid... Superseded Standard
C57.100-2011 - Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power TransformersA test procedure to provide a uniform method for investigating the effect of operating temperature on the life expectancy of liquid-immersed... Active Standard
C57.104-1978 - Guide for the Detection and Determination of Generated Gases in Oil-Immersed Transformers and Their Relation to the Serviceability of the EquipmentThe detection of certain gases generated in an oil-filled transformer in service is frequently the first available indication of a possible... Superseded Standard
C57.104-1991 - Guide for the Interpretation of Gases Generated in Oil-Immersed TransformersDetailed procedures for analyzing gas from gas spaces or gas-collecting devices as well as gas dissolved in oil are described for use in power... Withdrawn Standard
C57.104-2008 - Guide for the Interpretation of Gases Generated in Oil-Immersed TransformersDetailed procedures for analyzing gas from gas spaces or gas-collecting devices as well as gas dissolved in oil are described. The procedures... Active Standard
C57.105-1978 - Guide for Application of Transformer Connections in Three-Phase Distribution SystemsThis guide concerns transformer connections in 3-phase distribution systems. Distribution systems are characterized by primary voltages up to and... Active Standard
C57.106-1977 - Guide for Acceptance and Maintenance of Insulating Oil in EquipmentThe purpose of this guide is to assist the power equipment operator in evaluating the serviceability of oil received in equipment; oil as received... Superseded Standard
C57.106-1991 - Guide for Acceptance and Maintenance of Insulating Oil in EquipmentIn this IEEE Guide, recommendations are made regarding oil tests and evaluation procedures; methods of reconditioning and reclaiming conventional... Superseded Standard
C57.106-2002 - Guide for Acceptance and Maintenance of Insulating Oil in EquipmentRecommendations regarding oil tests and evaluation procedures are made in this guide; references are made to methods of reconditioning and... Superseded Standard
C57.106-2006 - Guide for Acceptance and Maintenance of Insulating Oil in EquipmentRecommendations regarding oil tests and evaluation procedures are made in this guide; references are made to methods of reconditioning and... Active Standard
C57.109-1985 - Guide for Transformer Through-Fault-Current DurationProtective devices such as relays and fuses have well-defined operating characteristics that relate fault magnitude to operating time. It is... Superseded Standard
C57.109-1993 - Guide for Liquid-Immersed Transformers Through-Fault-Current DurationRecommendations believed essential for the application of overcurrent protective devices applied to limit the exposure time of transformers to... Active Standard
C57.110-1986 - Recommended Practice for Establishing Transformer Capability When Supplying Nonsinusoidal Load CurrentsThe purpose of the report is to establish uniform methods for determining the capability of transformers to supply nonsinusoidal load currents,... Superseded Standard
C57.110-1998 - Recommended Practice for Establishing Transformer Capability When Supplying Nonsinusoidal Load CurrentsMethods are developed to conservatively evaluate the feasibility of supplying additional nonsinusoidal load currents from an existing installed... Superseded Standard
C57.110-2008 - Recommended Practice for Establishing Liquid-Filled and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load CurrentsThis recommended practice provides calculation methods to conservatively evaluate the feasibility for an existing installed dry-type or liquid... Active Standard
C57.111-1989 - Guide for Acceptance of Silicone Insulating Fluid and Its Maintenance in TransformersThis IEEE guide recommends standard tests and evaluation procedures for silicone transformer fluid. Criteria for maintenance and methods of... Active Standard
C57.113-1988 - Trial-Use Guide for Partial Discharge Measurement in Liquid-Filled Power Transformers and Shunt ReactorsThis test procedure applies to the detection and measurement by the wide-band apparent charge method of partial discharges occuring in liquid... Superseded Standard
C57.113-2003 - Guide for Partial Discharge Measurement in Liquid-Filled Power Transformers and Shunt ReactorsThe detection and measurement by the wide-band apparent charge method of partial discharges occurring in liquid-filled power transformers and... Superseded Standard
C57.113-2010 - Recommended Practice for Partial Discharge Measurement in Liquid-Filled Power Transformers and Shunt ReactorsWideband measurement of the apparent charge of partial discharges (PDs) that may occur in liquid-filled power transformers and shunt reactors... Active Standard
C57.115-1991 - Guide for Loading Mineral-Oil-Immersed Power Transformers Rated in Excess of 100 MVA (65C Winding Rise) (Folded into C57.91-1995) (65C Winding Rise)The guide covers modern power transformers rated above 100 MVA, three-phase equivalent and 65 degrees C rise. The general approach is tutorial.... Withdrawn Standard
C57.120-1991 - Loss Evaluation Guide for Power Transformers and ReactorsIn this standard a method for establishing the dollar value of the electric power needed to supply the losses of a transformer or reactor is... Active Standard
C57.121-1989 - Guide for Acceptance and Maintenance of Less Flammable Hydrocarbon Fluid in TransformersThis standard covers the evaluation and handling procedures for less-flammable hydrocarbon transformer insulating fluids. Its purpose is to assist... Superseded Standard
C57.121-1998 - Guide for Acceptance and Maintenance of Less-Flammable Hydrocarbon Fluid in TransformersThe evaluation and handling procedures for less flammable hydrocarbon power transformer insulating fluids are covered. The guide's purpose is to... Active Standard
C57.123-2002 - Guide for Transformer Loss MeasurementInformation and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding... Superseded Standard
C57.123-2010 - Guide for Transformer Loss MeasurementInformation and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding... Active Standard
C57.124-1991 - Recommended Practice for the Detection of Partial Discharge and the Measurement of Apparent Charge in Dry-Type TransformersIEEE Std C57.124-1991 covers the detection of partial discharges occurring in the insulation of dry-type transformers of their components and the... Active Standard
C62.1-1989 - Gapped Silicon-Carbide Surge Arresters for AC Power CircuitsThis standard applies to gapped silicon-carbide surge-protective devices designed for the repeated limiting of voltage surges on 50 Hz or 60 Hz... Withdrawn Standard
C62.2-1987 - Guide for the Application of Gapped Silicon-Carbide Surge Arresters for Alternating Current SystemsThis standard covers the application of gapped silicon-carbide surge arresters to safeguard electric power equipment against the hazards of... Withdrawn Standard
C62.11-1987 - Metal-Oxide Surge Arresters for AC Power CircuitsThe standard applies to metal-oxide surge arresters designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz AC power circuits by passing... Superseded Standard
C62.11-1993 - Metal-Oxide Surge Arresters for Alternating Current Power CircuitsMetal-oxide surge arresters designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits by passing surge discharge current... Superseded Standard
C62.11-1999 - Metal-Oxide Surge Arresters for Alternating Current Power Circuits (>1KV)Metal-oxide surge arresters designed to repeatedly limit the voltage surges on 48-62 Hz power circuits (>1 kV) are covered in this standard. These... Superseded Standard
C62.11-2005 - Metal-Oxide Surge Arresters for AC Power Circuits (> 1 kV)This standard applies to metal-oxide surge arresters (MOSAs) designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (... Superseded Standard
C62.11-2012 - Metal-Oxide Surge Arresters for AC Power Circuits (>1 kV)Metal-oxide surge arresters (MOSAs) designed to repeatedly limit the voltage surges on 48 Hz to 62 Hz power circuits (􀀡 1000 V) by... Active Standard
C62.22-1991 - Guide for the Application of Metal Oxide Surge Arresters for AC SystemsIn this standard, the application of metal-oxide surge arresters to safeguard electric power equipment against the hazards of abnormally high... Superseded Standard
C62.22-1997 - Guide for Application of Metal-Oxide Surge Arresters for Alternating-Current SystemsThe application of metal-oxide surge arresters to safeguard electric power equipment against the hazards of abnormally high voltage surges of... Superseded Standard
C62.22-2009 - Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current SystemsThis guide covers the application of metal-oxide surge arresters to safeguard electric power equipment, with a nominal operating voltage 1000 V... Active Standard
C62.22.1-1996 - Guide for the Connection of Surge Arresters to Protect Insulated, Shielded Electric Power Cable SystemsThis guide suggests surge arrester installation methods at distribution cable terminal poles in order to minimize the total impressed transient... Active Standard
C62.36-1991 - Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling CircuitsMethods are established for testing and measuring the characteristics of surge protectors used in low-voltage data, communications, and signaling... Superseded Standard
C62.36-1994 - Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling CircuitsMethods are established for testing and measuring the characteristics of surge protectors used in low-voltage data, communications, and signaling... Superseded Standard
C62.36-2000 - Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling CircuitsMethods for testing and measuring the characteristics of surge protectors used in low-voltage data, communications, and signaling circuits with... Superseded Standard
C62.36-2014 - Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling CircuitsSurge protectors for application on multiconductor balanced or unbalanced data, communications, and signaling circuits with voltages equal to or... Active Standard
C62.41-1980 - Guide for Surge Voltages in Low-Voltage AC Power CircuitsThis IEEE guide for surge voltages in LV AC power circuits addresses circuits with rated voltages up to 277 V line to ground. The main purpose of... Superseded Standard
C62.41-1991 - Recommended Practice for Surge Voltages in Low-Voltage AC Power CircuitsA practical basis is provided for the selection of voltage and current tests to be applied in evaluating the surge withstand capability of... Superseded Standard
C62.41.1-2002 - Guide on the Surge Environment in Low-Voltage (1000 V and less) AC Power CircuitsThis is a guide describing the surge voltage, surge current, and temporary overvoltages (TOV) environment in low-voltage [up to 1000 V root mean... Active Standard
C62.41.2-2002 - Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and less) AC Power CircuitsThe scope of this recommended practice is to characterize the surge environment at locations on AC power circuits described in IEEE Std C62.41.1... Active Standard
C62.45-1987 - Guide on Surge Testing for Equipment Connected to Low-Voltage AC Power CircuitsThis document provides guidance on surge testing AC power interfaces of equipment connected to low-voltage circuits that are subject to transient... Superseded Standard
C62.45-1992 - Guide on Surge Testing for Equipment Connected to Low-Voltage AC Power CircuitsGuidance is provided for applying surge testing to ac power interfaces of equipment connected to low-voltage ac power circuits that are subject to... Superseded Standard
C62.45-2002 - Recommended Practice on Surge Testing for Equipment Connected to Low-Voltage (1000 V and less) AC Power CircuitsThe scope of this recommended practice is the performance of surge testing on electrical and electronic equipment connected to low-voltage ac... Active Standard
C62.92-1987 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part 1 - IntroductionSome basic considerations for the selection of neutral grounding parameters that will provide for the control of ground-fault current and... Superseded Standard
C62.92.1-1987 - Guide for the Application of Neutral Grounding in Electrical Utility Systems Part I--IntroductionThe purpose of this guide and subsequent revisions to IEEE Std 143-1954 [8]1 is to present some basic considerations for the selection of neutral... Active Standard
C62.92.1-2000 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part 1 - IntroductionThis guide is the introduction to the C62.92 series of five IEEE guides on neutral grounding in three-phase electrical utility systems. It... Active Standard
C62.92.3-1993 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III - Generator Auxiliary SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power... Superseded Standard
C62.92.3-2012 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part III -Generator Auxiliary SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power... Active Standard
C62.92.4-1991 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part IV-DistributionIn this standard the neutral grounding of singleand three-phase AC electric utility primary distribution systems with nominal voltages in the... Active Standard
C62.92.5-2000 - Guide for the Application of Neutral Grounding in Electric Utility Systems, Part V - Transmission Systems and Subtransmission SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for a particular ac transmission or subtransmission... Superseded Standard
C62.92.5-2009 - Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part V-Transmission Systems and Subtransmission SystemsBasic factors and general considerations in selecting the class and means of neutral grounding for a particular ac transmission or subtransmission... Active Standard
C63.4-1988 - American National Standard Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 10 kHz to 1GHzUniform methods of measurement of radio noise emitted from low-voltage electrical and electronic equipment, including digital and other... Superseded Standard
C63.4-1991 - American National Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzThis standard sets forth uniform methods of measurement of radio noise emitted from low-voltage electrical and electronic equipment, including... Superseded Standard
C63.4-1992 - Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzUniform methods of measurement of radio noise emitted from low-voltage electrical and electronic equipment, including digital and other... Superseded Standard
C63.4-2000 - Interim Standard Methods of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzU.S. consensus standard methods, instrumentation, and facilities for measurement of radio-frequency (RF) signals and noise emitted from electrical... Superseded Standard
C63.4-2003 - Methods of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzU.S. consensus standard methods, instrumentation, and facilities for measurement of radio-frequency (RF) signals and noise emitted from electrical... Active Standard
C63.4-2009 - American National Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzU.S. consensus standard methods, instrumentation, and facilities for measurement of radio-frequency (RF) signals and noise emitted from electrical... Superseded Standard
C63.4-2014 - American National Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzANSI C63.4, conducted emission testing, conducting ground plane, digital equipment, electric field measurement, line impedance stabilization... Active Standard
C63.5-1998 - American National Calibration of Antennas Used for Radiated Emission Measurements in Electromagnetic Interference (EMI) Control Calibration of Antennas (9 kHz to 40 GHz)Methods for determining antenna factors of antennas used for radiated emission measurements of electromagnetic interference (EMI) from 9 kHz to 40... Superseded Standard
C63.5-2004 - American National Electromagnetic CompatibilityRadiated Emission Measurements in Electromagnetic Interference (EMI) ControlCalibration of Antennas (9 kHz to 40 GHz)Methods for determining antenna factors of antennas used for radiated emission measurements of electromagnetic interference (EMI) from 9 kHz to 40... Superseded Standard
C63.5-2006 - American National Electromagnetic Compatibility Radiated Emission Measurements in Electromagnetic Interference (EMI) Control Calibration of Antennas (9 kHz to 40 GHz)Methods for determining antenna factors of antennas used for radiated emission measurements of electromagnetic interference (EMI) from 9 kHz to 40... Active Standard
C63.6-1988 - American National Standard Guide for electromagnetic compatibility--open-area test site measurements--guide for the computation of errorsShows the basis for the acceptability criterion of +or-14 dB for the site attenuation measurements required in ANSI C63.4-1988. This covers... Superseded Standard
C63.6-1996 - American National Standard Guide for the Computation of Errors in Open-Area Test Site MeasurementsThe basis for the acceptability criterion of /spl plusmn/4 dB for the site attenuation measurements required in ANSI C63.4-1992 is provided. Active Standard
C63.7-1992 - American National Standard Guide for Construction of Open-Area Test Sites for Performing Radiated Emission MeasurementsInformation that is useful in constructing an open-area test site (OATS) used to perform radiated emission measurements in the frequency range of... Superseded Standard
C63.7-2005 - Standard Guide for Construction of Open Area Test Sites for Performing Radiated Emission MeasurementsInformation that is useful in constructing an open-area test site used to perform radiated emission measurements in the frequency range of 30 MHz... Active Standard
C63.011-2000 - American National Limits and Methods of Measurement of Radio Disturbance Characteristics of Industrial, Scientific, and Medical (ISM) Radio-Frequency EquipmentThis standard republishes CISPR 11:1997 (with Amendment 1, 1999-05) as an American National Standard to make it easily available to U.S.... Active Standard
C63.15-2010 - American National Standard Recommended Practice for the Immunity Measurement of Electrical and Electronic EquipmentThis immunity measurement and measurement instrumentation specification document complements the recommended procedures for making emission... Active Standard
C63.17-2006 - American National Standard Methods of Measurement of the Electromagnetic and Operational Compatibility of Unlicensed Personal Communications Services (UPCS) DevicesSpecific test procedures are established for verifying the compliance of unlicensed personal communications services (UPCS) devices with... Superseded Standard
C63.17-2013 - American National Standard Methods of Measurement of the Electromagnetic and Operational Compatibility of Unlicensed Personal Communications Services (UPCS) DevicesSpecific test procedures for verifying the compliance of unlicensed personal communications services (UPCS) devices (including wideband voice and... Active Standard
C63.19-2001 - American National Methods of Measurement of Capatibility between Wireless Communication Devices and Hearing AidsUniform methods of measurement for compatibility between hearing aids and wireless communications devices are set forth in this standard. Active Standard
C63.19-2006 - Method of Measurement for Hearing Aid Compatibility with Wireless CommunicationsUniform methods of measurement for compatibility between hearing aids and wireless communications devices are set forth. Active Standard
C63.19-2007 - American National Standard Methods of Measurement for Hearing Aid Compatibility with Wireless CommunicationsUniform methods of measurement for compatibility between hearing aids and wireless communications devices are set forth. American national... Active Standard
C63.19-2011 - American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing AidsAvailable in PDF only. Uniform methods of measurement for compatibility between hearing aids and wireless communications devices are set forth. Active Standard
C63.022-1996 - American National Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology EquipmentEmission limits are provided that are an are acceptable alternative for limits of the current issue of FCC Part 15, Subpart B, for Information... Active Standard
C63.22-2004 - American National Standard Guide for Automated Electromagnetic Interference MeasurementsU.S. consensus guideline for automation of conducted and radiated EMI compliance measurements is provided in this guide. This document does not... Active Standard
C63.23-2012 - American National Standard Guide for Electromagnetic Compatibility—Computations and Treatment of Measurement UncertaintyMethods for estimating measurement uncertainty of emissions measurement results are provided, for use in conjunction with the basic methods of... Active Standard
C92.2-1987 - American National Power Systems - Alternating-Current Electrical Systems and Equipment Operating at Voltages Above 230 kV Nominal-Preferred Voltage RatingsThe article presents ANSI standard C92.2-1987. This standard supersedes ANSI C92.2-1981, preferred voltage ratings for alternating-current... Superseded Standard
C95.3-1991 - Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and MicrowaveIEEE Std C95.3-1991 specifies techniques and instrumentation for the measurement of potentially hazardous electromagnetic fields. The... Superseded Standard
C95.3-2002 - Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHzTechniques and instrumentation for the measurement and computation of potentially hazardous electromagnetic (EM) fields both in the near field and... Active Standard
C95.3.1-2010 - Recommended Practice for Measurements and Computations of Electric, Magnetic, and Electromagnetic Fields with Respect to Human Exposure to Such Fields, 0 Hz to 100 kHzTechniques and instrumentation for the measurement and computation of electric, magnetic, and electromagnetic (EM) fields in the near field of an... Active Standard
C95.5-1981 - American National Standard Recommended Practice for the Measurement of Hazardous Electromagnetic Fields - RF and MicrowaveThis recommended practice describes techniques and procedures for the measurement of potentially hazardous electromagnetic fields both in the near... Superseded Standard
N42.14-1978 - American National Standard Calibration and Usage of Germanium Detectors for Measurement of Gamma-Ray Emission of RadionuclidesThis standard establishes methods for calibration and usage of germanium detectors for the measurement of gamma-ray emission rates of... Superseded Standard
N42.14-1991 - American National Standard Calibration and Use of Germanium Spectrometers for the Measurement of Gamma-Ray Emission Rates of RadionuclidesMethods for the calibration and use of germanium spectrometers for the measurement of gamma-ray energies and emission rates over the energy range... Active Standard
N42.14-1999 - American National Calibration and use of germanium spectrometers for the measurement of gamma-ray emission rates of radionuclidesMethods for the calibration and use of germanium spectrometers for the measurement of gamma-ray energies and emission rates over the energy range... Active Standard
N42.23-1996 - American National Standard Measurement and Associated Instrumentation Quality Assurance for Radioassay LaboratoriesA framework that can be used to create a national or an organizational NIST-traceable measurement quality assurance (MQA) program that will... Active Standard
N42.28-2002 - American National Standard Calibration of Germanium Detectors for In-Situ Gamma-Ray MeasurementsThe need for accurately measuring radioactivity in-situ for a variety of detector characterization techniques requires that performance criteria... Active Standard
N42.31-2003 - American National Measurement Procedures for Resolution and Efficiency of Wide-Bandgap Semiconductor Detectors of Ionizing RadiationStandard measurement and test procedures are established for wide-bandgap semiconductor detectors such as cadmium telluride (CdTe), cadmium-zinc... Active Standard
N42.47-2010 - American National Measuring the Imaging Performance of X-ray and Gamma-ray Systems for Security Screening of HumansThis standard applies to security screening systems that utilize x-ray or gamma radiation and are used to inspect people who are not inside... Active Standard
Y32.9-1972 - Graphic Symbols for Electrical Wiring and Layout Diagrams Used in Architecture and Building ConstructionThis standard provides a basis for showing the general physical location and arrangement of the sections of the required wiring system, and... Active Standard