Industry Applications Standards

Displaying results 1 - 40 of 922
Standard Name
Status Help less all
3-1982 - Recommended Practice in the Selection of Reference Ambient Conditions for Test Measurements of Electrical ApparatusIn general test results and the performance of electrical apparatus are significantly influenced by variations in such parameters as temperature,... Withdrawn Standard
4a-2001 - Amendment to Standard Techniques for High-Voltage TestingThis amendment sets forth a number of clarifications and corrections to IEEE Standard Techniques for High-Voltage Testing. Superseded Standard
11-1980 - Rotating Electric Machinery for Rail and Road VehiclesThis IEEE standard applies to rotating electric machinery which forms part of the propulsion and major auxiliary equipment on internally and... Superseded Standard
11-2000 - Rotating Electric Machinery for Rail and Road VehiclesThis standard applies to rotating electric machinery which forms part of the propulsion and major auxiliary equipment on internally and externally... Active Standard
18-1980 - Shunt Power CapacitorsThis standard applies to capacitors rated 216 V or higher, 5 kVAr or more, and designed for shunt connection to alternating current transmission... Superseded Standard
18-1992 - Shunt Power CapacitorsCapacitors rated 216 V or higher, 2.5 kVAr or more, and designed for shunt connection to alternating-current transmission and distribution systems... Superseded Standard
18-2002 - Shunt Power CapacitorsCapacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection to alternating-current transmission and distribution systems... Superseded Standard
18-2012 - Shunt Power CapacitorsPower capacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection to alternating-current transmission and distribution... Active Standard
32-1972 - Standard Requirements, Terminology, and Test Procedures for Neutral Grounding DevicesThis standard applies to devices used for the purpose of controlling the ground current or the potentials to ground of an alternating current... Active Standard
43-1974 - Recommended Practice for Testing Insulation Resistance of Rotating MachineryThis document describes the recommended procedure for the measurement of insulation resistance of windings of rotating machines rated 1 hp, 1 kW... Superseded Standard
43-2000 - Recommended Practice for Testing Insulation Resistance of Rotating MachineryThis document describes the recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 1... Superseded Standard
43-2013 - Recommended Practice for Testing Insulation Resistance of Electric MachineryThe dc voltage tests procedures for the measurement of the insulation resistance and polarization index of insulated stator, and rotor windings... Active Standard
45-1998 - Recommended Practice for Electric Installations on ShipboardRecommendations for the selection and installation of equipment on merchant vessels with electric apparatus for lighting, signaling, communication... Superseded Standard
45-2002 - Recommended Practice for Electric Installations on ShipboardRecommendations for the design, selection, and installation of equipment on merchant vessels with electrical apparatus for lighting, signaling,... Active Standard
45.2-2011 - Recommended Practice for Electrical Installations on Shipboard -- Controls and AutomationThe recommendations for controls, control applications, control apparatus, and automation on shipboards are established by this document. These... Active Standard
45.7-2012 - Recommended Practice for Electrical Installations on Shipboard -- AC SwitchboardsRecommendations for the design, selection, and installation of switchboards on merchant vessels with electrical apparatus for lighting, signaling,... Active Standard
48-1975 - Standard Test Procedures and Requirements for High-Voltage Alternating-Current Cable TerminationsThis standard encompasses all (with one exception) terminations for alternating-current high-voltage cables having laminated or extruded... Superseded Standard
48-1990 - Standard Test Procedures and Requirements for High-Voltage Alternating-Current Cable TerminationsThis standard covers all indoor and outdoor cable terminations used on alternating-current cables having laminated or extruded insulation rated 2... Superseded Standard
48-1996 - Standard Test Procedures and Requirements for Alternating-Current Cable Terminations 2.5 kV Through 765 kVAll indoor and outdoor cable terminations used on alternating-current cables having laminated or extruded insulation rated 2.5 kV through 765 kV... Superseded Standard
48-2009 - Test Procedures and Requirements for Alternating-Current Cable Terminations Used on Shielded Cables Having Laminated Insulation Rated 2.5 kV through 765 kV or Extruded Insulation Rated 2.5 kV through 500 kVThis standard covers all indoor and outdoor cable terminations used on alternating-current shielded cables having laminated insulation from 2.5 kV... Active Standard
55-1953 - Guide for Temperature Correlation in the Connection of Insulated Wire and Cables to Electronic EquipmentAlthough the standard permissible operating temperatures of various types of equipment are different for one reason or another, this causes little... Withdrawn Standard
56-1977 - Guide for Insulation Maintenance of Large Alternating-Current Rotating Machinery (10,000 kVA and Larger)The purpose of this IEEE guide is to present information necessary to permit an effective evaluation of the insulation systems of large... Withdrawn Standard
58-1978 - Standard Induction Motor Letter SymbolsWithdrawn Standard. Withdrawn Date: Dec 05, 1991. Withdrawn Standard
62-1995 - Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and ReactorsIn this IEEE Standard, diagnostic tests and measurements that are performed in the field on oil-immersed power transformers and regulators are... Superseded Standard
62.2-2004 - Guide for Diagnostic Field Testing of Electric Power Apparatus - Electrical MachineryThis is a guide for determining applicable tests and inspection techniques for various types of large rotating electric machines. It provides... Active Standard
67-1972 - Guide for Operation and Maintenance of Turbine GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators with cylindrical... Superseded Standard
67-1990 - Guide for Operation and Maintenance of Turbine GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators having cylindrical... Superseded Standard
67-2005 - Guide for Operation and Maintenance of Turbine GeneratorsThis guide covers general recommendations for the operation, loading, and maintenance of turbine-driven synchronous generators that have... Active Standard
80-1986 - Guide for Safety in AC Substation GroundingThe third edition of this guide represents the first major revision since its first issue in 1961. Major modifications include the redefinition of... Superseded Standard
80-2000 - Guide for Safety in AC Substation GroundingOutdoor ac substations, either conventional or gas-insulated, are covered in this guide. Distribution, transmission, and generating plant... Superseded Standard
80-2013 - Approved Draft Guide for Safety in AC Substation GroundingThis guide is primarily concerned with outdoor AC substatons, either air-insulated or gas-insulated. Distribution, transmission and power plant... Active Standard
81-1983 - Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System Part 1: Normal MeasurementsThe technique of measuring ground resistance and impedance, earth resistivity, potential gradients from currents in the earth, and the prediction... Superseded Standard
81-2012 - Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding SystemPractical test methods and techniques are presented for measuring the electrical characteristics of grounding systems. Topics addressed include... Active Standard
81.2-1991 - Guide for Measurement of Impedance and Safety Characteristics of Large, Extended or Interconnected Grounding SystemsThe purpose of this guide is to present practical instrumentation methods that may be used for the measurement of impedance to remote earth, step... Withdrawn Standard
82-1994 - Standard Test Procedure for Impulse Voltage Tests on Insulated ConductorsA test procedure for impulse testing of insulated conductors (cables) and cables with accessories installed (cable systems) is provided in this... Withdrawn Standard
82-2002 - Standard Test Procedure for Impulse Voltage Tests on Insulated ConductorsA test procedure for the impulse testing of insulated conductors (cables) and cables with accessories installed (cable systems) is provided in... Active Standard
83-1963 - Test Procedure for Radial Power Factor Tests on Insulating Tapes in Paper-Insulated Power CableA test procedure for determining the radial power factor of insulating tapes in power cable is presented. Three-terminal type electrodes are... Withdrawn Standard
Displaying results 1 - 40 of 922 - all results