450-1972 - Recommended Practice for Maintenance, Testing, and Replacement of Large Stationary Type Power Plant and Substation Lead Storage BatteriesProper maintenance will prolong the life of a battery and will aid in assuring that it is capable of supplying its design power requirements. A... Superseded Standard
450-1975 - EEE Recommended Practice for Maintenance, Testing, and Replacement of Large Lead Storage Batteries for Generating Stations and SubstationsLarge stationary lead storage batteries play an ever increasing role in substation and generating station control systems and in providing the... Superseded Standard
450-1987 - Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and SubstationsThis recommended practice is limited to providing recommended practices of maintenance, test schedules, and testing procedures than can be used to... Superseded Standard
450-1995 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-2002 - Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-2010 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary ApplicationsMaintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Active Standard
484-1987 - Recommended Practice for Installation Design and Installation of Large Lead Storage Batteries for Generating Stations and SubstationsProvides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly and... Superseded Standard
484-1996 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary ApplicationsIn this IEEE Standard recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
484-2002 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary ApplicationsRecommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of... Active Standard
485-1983 - Recommended Practice for Sizing Large Lead Storage Batteries for Generating Stations and SubstationsMethods for defining the dc load in a generating station or a substation and for sizing a lead storage battery to supply that load are described.... Superseded Standard
485-1997 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary ApplicationsMethods for defining the DC load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float... Superseded Standard
485-2010 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary ApplicationsMethods for defining the direct current (dc) load and for sizing a lead-acid battery to supply that load for stationary battery applications in... Active Standard
535-1986 - Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating StationsThe objective of qualification is to demonstrate that the batteries and racks, as installed, will perform their required Class 1E function... Superseded Standard
535-2006 - Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating StationsQualification methods for class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary... Superseded Standard
535-2013 - Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating StationsQualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary... Active Standard
650-1979 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating StationsThis standard describes methods for qualifying static battery chargers and inverters for Class 1E installations in environmentally controlled... Superseded Standard
650-1990 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating StationsMethods for qualifying static battery chargers and inverters for Class 1E installations in a mild environment outside containment in nuclear power... Superseded Standard
650-2006 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating StationsMethods for qualifying static battery chargers and inverters for Class 1E installations outside containment in nuclear power generating stations... Active Standard
937-1987 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) SystemsThis recommended practice provides design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of... Superseded Standard
937-2000 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) SystemsDesign considerations and procedures for storage, location, mounting, ventilation, assembly and maintenance, of lead-acid storage batteries for... Superseded Standard
937-2007 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) SystemsDesign considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of lead-acid secondary batteries for... Active Standard
1013-1990 - Recommended Practice for Sizing Lead-Acid Batteries for Photovoltaic (PV) SystemsDescribes methods for sizing both vented and valve regulated lead-acid batteries used with terrestrial photovoltaic (PV) systems. The purpose is... Superseded Standard
1013-2000 - Recommended Practice for Sizing Lead-Acid Batteries for Photovoltaic (PV) SystemsA method for sizing both vented and valve-regulated lead-acid batteries used in terrestrial photovoltaic (PV) systems is described. Installation,... Superseded Standard
1013-2007 - Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) SystemsA method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial... Active Standard
1106-1987 - Recommended Practice for Maintenance, Testing, and Replacement of Nickel-Cadmium Storage Batteries for Generating Stations and SubstationsThis recommended practice provides maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of... Superseded Standard
1106-1995 - Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary ApplicationsInstallation design, installation, maintenance and testing procedures, and test schedules that can be used to optimize the life and performance of... Superseded Standard
1106-2005 - Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary ApplicationsThis recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be... Active Standard
1115-1992 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary ApplicationsMethods for defining the dc load and for sizing a nickel-cadmium battery to supply that load are described. Installation, maintenance,... Superseded Standard
1115-2000 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary ApplicationsThe sizing of nickel-cadmium batteries used in full float operation for stationary applications is covered in this recommended practice. Superseded Standard
1115-2014 - Approved Draft Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary ApplicationsThis recommended practice covers the sizing of nickel-cadmium batteries used in standby operation for stationary applications. Active Standard
1115a-2007 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications Amendment 1: Additional Discussion on Sizing MarginsThis amendment provides additional guidance on sizing margins that may be applied when nickel-cadmium batteries are used in stationary... Superseded Standard
1144-1996 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Photovoltaic (PV) SystemsA method for sizing nickel-cadmium battery storage subsystems used in residential, commercial, and industrial photovoltaic (PV) systems is described. Withdrawn Standard
1145-1990 - Recommended Practice for Installation and Maintenance of Nickel-Cadmium Batteries for Photovoltaic (PV) SystemsThe IEEE Recommended Practice for Installation and Maintenance of Nickel-Cadmium Batteries for Photovoltaic (PV) Systems, provides safety... Superseded Standard
1145-1999 - Recommended Practice for the Installation and Maintenance of Nickel-Cadmium Batteries for Photovoltaic (PV) SystemsSafety precautions, installation design considerations, and procedures for receiving, storing, commissioning, and maintaining pocketand fiber... Withdrawn Standard
1184-1994 - Guide for the Selection and Sizing of Batteries for Uninterruptible Power SystemsThe characteristics of the various battery energy systems available are described so that users can select the system best suited to their... Superseded Standard
1184-2006 - Guide for Batteries for Uninterruptible Power Supply SystemsVarious battery systems are discussed so that the user can make informed decisions on selection, installation design, installation, maintenance,... Active Standard
1187-1996 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Storage Batteries for Stationary ApplicationsThis IEEE standard covers recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
1187-2002 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary ApplicationsThis recommended practice provides guidance for the installation and installation design of valve-regulated lead acid (VRLA) batteries. This... Superseded Standard
1187-2013 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary ApplicationsThis recommended practice provides guidance for the installation and installation design of valve-regulated lead acid (VRLA) batteries. This... Active Standard
1188-1996 - Recommended Practice for Maintenance, Testing, and Replacement of Valve- Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsIn this IEEE standard maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of valve-regulated... Superseded Standard
1188-2005 - Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsThis recommended practice is limited to maintenance, test schedules, and testing procedures that can be used to optimize the life and performance... Active Standard
1188a-2014 - Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications - Amendment 1: Updated VRLA Maintenance ConsiderationsNew guidance to users dealing with premature capacity failures with VRLA batteries and updated definitions are addressed in this amendment. Active Standard
1189-1996 - Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsMethods for selecting the appropriate type of valve-regulated, immobilized-electrolyte, recombinant lead-acid battery for any of a variety of... Superseded Standard
1189-2007 - Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary ApplicationsThis guide describes methods for selecting the appropriate type of valve-regulated, immobilized-electrolyte, recombinant lead-acid battery for any... Active Standard
1361-2003 - Guide for Selection, Charging, Test and Evaluation of Lead-Acid Batteries Used in Stand-Alone Photovoltaic (PV) SystemsThis guide is applicable to all stand-alone photovoltaic (PV) systems where PV is the only charging source. Stand-alone photovoltaic (PV) system... Superseded Standard
1361-2014 - Guide for Selecting, Charging, Testing, and Evaluating Lead-Acid Batteries Used in Stand-Alone Photovoltaic (PV) SystemsThis guide is applicable to all stand-alone photovoltaic (PV) systems where PV is the only charging source. Stand-alone PV system parameters and... Active Standard
1375-1998 - Guide for the Protection of Stationary Battery SystemsGuidance in the protection of stationary battery systems is provided. For the purposes of this guide, stationary battery systems include the... Active Standard
1491-2005 - Guide for Selection and Use of Battery Monitoring Equipment in Stationary ApplicationsMonitoring and measurement of battery parameters is an important element of maintaining a fully operational battery system. This guide presents... Superseded Standard
1491-2012 - Guide for Selection and Use of Battery Monitoring Equipment in Stationary ApplicationsOperational parameters that may be observed by battery monitoring equipment used in stationary applications and the relative value of such... Active Standard
1536-2002 - Rail Transit Vehicle Battery Physical InterfaceThe maximum dimensional requirements of each battery tray for a specific number of cells and battery capacity or performance rating are prescribed... Active Standard
1561-2007 - Guide for Optimizing the Performance and Life of Lead-Acid Batteries in Remote Hybrid Power SystemsThis guide is applicable to lead-acid batteries that are used as the energy storage component in remote hybrid power supplies. The remote hybrid... Active Standard
1562-2007 - Guide for Array and Battery Sizing in Stand-Alone Photovoltaic (PV) SystemsA method for properly sizing the PV array and battery for stand-alone PV systems where PV is the only charging source is recommended (in... Active Standard
1568-2003 - Recommended Practice for Electrical Sizing of Nickel-Cadmium Batteries for Rail Passenger VehiclesA method for defining the electrical load supplied by a nickel-cadmium battery and for sizing the battery to supply that load is described in this... Active Standard
1578-2007 - Recommended Practice for Stationary Battery Electrolyte Spill Containment and ManagementDescriptions of products, methods, and procedures relating to stationary batteries, battery electrolyte spill mechanisms, electrolyte containment... Active Standard
1625-2004 - Rechargeable Batteries for Portable ComputersGuidance for the designer/manufacturer/supplier in planning and implementing controls for the design and manufacture of lithium-ion (Li-ion) and... Superseded Standard
1625-2004 - Rechargeable Batteries for Portable ComputingGuidance for the designer/manufacturer/supplier in planning and implementing controls for the design and manufacture of lithium-ion (Li-ion) and... Superseded Standard
1625-2008 - Rechargeable Batteries for Multi-Cell Mobile Computing DevicesThis standard guides manufacturers/suppliers in planning and implementing the controls for the design and manufacture of lithium-ion (Li-ion) and... Active Standard
1635-2012 - /ASHRAE Guide for the Ventilation and Thermal Management of Batteries for Stationary ApplicationsVented lead-acid (VLA), valve-regulated lead-acid (VRLA), and nickel-cadmium (NiCd) stationary battery installations are discussed in this guide,... Active Standard
1657-2009 - Recommended Practice for Personnel Qualifications for Installation and Maintenance of Stationary BatteriesThis recommended practice defines the areas of recommended knowledge for installers and maintainers of stationary batteries and related systems to... Active Standard
1660-2008 - Guide for Application and Management of Stationary Batteries Used in Cycling ServiceA stationary battery can be operated in two basic modes: 1) standby (or float) and 2) cycling. Many standards developed for standby stationary... Active Standard
1661-2007 - Guide for Test and Evaluation of Lead-Acid Batteries Used in Photovoltaic (PV) Hybrid Power SystemsThis guide is specifically prepared for a PV/engine generator hybrid power system, but may also be applicable to all hybrid power systems where... Active Standard
1679-2010 - Recommended Practice for the Characterization and Evaluation of Emerging Energy Storage Technologies in Stationary ApplicationsRecommended information for an objective evaluation of an emerging energy storage device or system by a potential user for any stationary... Active Standard
1725-2006 - Rechargeable Batteries for Cellular TelephonesThis standard establishes criteria for design analysis for quality and establishes criteria for reliability of rechargeable Li-Ion and Li-Ion... Superseded Standard
1725-2011 - Rechargeable Batteries for Cellular TelephonesCriteria for design analysis for qualification, quality, and reliability of rechargeable lithium ion and lithium ion polymer batteries for... Active Standard
2030-2011 - Guide for Smart Grid Interoperability of Energy Technology and Information Technology Operation with the Electric Power System (EPS), End-Use Applications, and LoadsIEEE Std 2030 provides alternative approaches and best practices for achieving smart grid interoperability. It is the first all-encompassing IEEE... Active Standard