Standard Icon

Batteries Standards

Displaying results 1 - 40 of 79
Standard Name
StatusHelp
400.2-2013 - Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded... Active Standard
400.2-2004 - Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) This guide describes very low frequency (VLF) withstand and diagnostic tests and the measurements that are performed in the field on shielded... Superseded Standard
400-1991 - Guide for Making High-Direct-Voltage Tests on Power Cable Systems in the Field Procedures and recommended test voltage values for acceptance and maintenance high-direct-voltage testing of shielded power cable systems are set... Superseded Standard
400-1980 - Guide for Making High-Direct-Voltage Tests on Power Cable Systems in the Field The purpose of this guide is: to provide uniform procedures for performing high-direct-voltage acceptance tests and maintenance tests on power... Superseded Standard
400-2012 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above Various field test methods that are currently available or under development are listed in this guide. The guide covers shielded, insulated power... Active Standard
400-2001 - Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems This guide lists the various field test methods that are currently available or under development with guidance on HOW to perform each test. The... Superseded Standard
422-1986 - Guide for the Design and Installation of Cable Systems in Power Generating Stations This guide provides guidance and recommended practices on the installation and maintenance of liquid-immersed power transformers rated 501 kVA and... Withdrawn Standard
422-2012 - Guide for the Design of Cable Raceway Systems for Electric Generating Facilities Guidance for the design and installation of cable raceway systems for all types of electric generating facilities is provided. Recommendations,... Active Standard
450-1995 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-1987 - Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and Substations This recommended practice is limited to providing recommended practices of maintenance, test schedules, and testing procedures than can be used to... Superseded Standard
450-1975 - EEE Recommended Practice for Maintenance, Testing, and Replacement of Large Lead Storage Batteries for Generating Stations and Substations Large stationary lead storage batteries play an ever increasing role in substation and generating station control systems and in providing the... Superseded Standard
450-1972 - Recommended Practice for Maintenance, Testing, and Replacement of Large Stationary Type Power Plant and Substation Lead Storage Batteries Proper maintenance will prolong the life of a battery and will aid in assuring that it is capable of supplying its design power requirements. A... Superseded Standard
450-2010 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Active Standard
450-2002 - Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary Applications Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
484-1996 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications In this IEEE Standard recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
484-1987 - Recommended Practice for Installation Design and Installation of Large Lead Storage Batteries for Generating Stations and Substations Provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly and... Superseded Standard
484-2002 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications Recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of... Active Standard
485-1997 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications Methods for defining the DC load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float... Superseded Standard
485-1983 - Recommended Practice for Sizing Large Lead Storage Batteries for Generating Stations and Substations Methods for defining the dc load in a generating station or a substation and for sizing a lead storage battery to supply that load are described.... Superseded Standard
485-2010 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications Methods for defining the direct current (dc) load and for sizing a lead-acid battery to supply that load for stationary battery applications in... Active Standard
535-1986 - Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating Stations The objective of qualification is to demonstrate that the batteries and racks, as installed, will perform their required Class 1E function... Superseded Standard
535-2013 - Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating Stations Qualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary... Active Standard
535-2006 - Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating Stations Qualification methods for class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary... Superseded Standard
650-1990 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations Methods for qualifying static battery chargers and inverters for Class 1E installations in a mild environment outside containment in nuclear power... Superseded Standard
650-1979 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations This standard describes methods for qualifying static battery chargers and inverters for Class 1E installations in environmentally controlled... Superseded Standard
650-2006 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations Methods for qualifying static battery chargers and inverters for Class 1E installations outside containment in nuclear power generating stations... Active Standard
738-1993 - Calculating the Current-Temperature of Bare Overhead Conductors A simplified method of calculating the current-temperature relationship of bare overhead lines, given the weather conditions, is presented. Along... Superseded Standard
738-1986 - Calculation of Bare Overhead Conductor Temperature and Ampacity Under Steady-State Conditions The purpose of this standard is to present a simplified method of calculating the current-temperature relationship of bare over-head lines when... Superseded Standard
738-2012 - Calculating the Current-Temperature Relationship of Bare Overhead Conductors A method of calculating the current-temperature relationship of bare overhead lines, given the weather conditions, is presented. Along with a... Active Standard
738-2006 - Calculating the Current-Temperature of Bare Overhead Conductors A method of calculating the current-temperature relationship of bare overhead lines, given the weather conditions, is presented. Along with a... Superseded Standard
937-2000 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems Design considerations and procedures for storage, location, mounting, ventilation, assembly and maintenance, of lead-acid storage batteries for... Superseded Standard
937-1987 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems This recommended practice provides design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of... Superseded Standard
937-2007 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems Design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of lead-acid secondary batteries for... Active Standard
946-1992 - Recommended Practice for the Design of DC Auxiliary Power Systems for Generating Stations Guidance for the design of the DC auxiliary power systems for nuclear and large fossil-fueled power generating stations is provided. The... Superseded Standard
946-1985 - Recommended Practice for the Design of Safety-Related DC Auxiliary Power Systems for Nuclear Power Generating Stations Guidance for the design of the dc auxiliary power systems for nuclear and large fossil-fueled power generating stations is provided. The... Superseded Standard
946-2004 - Recommended Practice for the Design of DC Auxiliary Power Systems for Generating Systems Guidance for the design of the dc auxiliary power systems for nuclear and non-nuclear power generating stations is provided by this recommended... Active Standard
1013-2000 - Recommended Practice for Sizing Lead-Acid Batteries for Photovoltaic (PV) Systems A method for sizing both vented and valve-regulated lead-acid batteries used in terrestrial photovoltaic (PV) systems is described. Installation,... Superseded Standard
1013-1990 - Recommended Practice for Sizing Lead-Acid Batteries for Photovoltaic (PV) Systems Describes methods for sizing both vented and valve regulated lead-acid batteries used with terrestrial photovoltaic (PV) systems. The purpose is... Superseded Standard
1013-2007 - Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems A method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial... Active Standard
1068-1996 - Recommended Practice for the Repair and Rewinding of Motors for the Petroleum and Chemical Industry General recommendations are provided for users of motors that need repair as well as owners and operators of establishments that offer motor... Superseded Standard
Displaying results 1 - 40 of 79 - all