Standard Icon

Batteries Standards

Displaying results 1 - 40 of 64
Standard Name
StatusHelp
450-1995 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
450-1987 - Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and Substations This recommended practice is limited to providing recommended practices of maintenance, test schedules, and testing procedures than can be used to... Superseded Standard
450-1975 - EEE Recommended Practice for Maintenance, Testing, and Replacement of Large Lead Storage Batteries for Generating Stations and Substations Large stationary lead storage batteries play an ever increasing role in substation and generating station control systems and in providing the... Superseded Standard
450-1972 - Recommended Practice for Maintenance, Testing, and Replacement of Large Stationary Type Power Plant and Substation Lead Storage Batteries Proper maintenance will prolong the life of a battery and will aid in assuring that it is capable of supplying its design power requirements. A... Superseded Standard
450-2010 - Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Active Standard
450-2002 - Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary Applications Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead... Superseded Standard
484-1996 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications In this IEEE Standard recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
484-1987 - Recommended Practice for Installation Design and Installation of Large Lead Storage Batteries for Generating Stations and Substations Provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly and... Superseded Standard
484-2002 - Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications Recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of... Active Standard
485-1997 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications Methods for defining the DC load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float... Superseded Standard
485-1983 - Recommended Practice for Sizing Large Lead Storage Batteries for Generating Stations and Substations Methods for defining the dc load in a generating station or a substation and for sizing a lead storage battery to supply that load are described.... Superseded Standard
485-2010 - Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications Methods for defining the direct current (dc) load and for sizing a lead-acid battery to supply that load for stationary battery applications in... Active Standard
535-1986 - Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating Stations The objective of qualification is to demonstrate that the batteries and racks, as installed, will perform their required Class 1E function... Superseded Standard
535-2013 - Qualification of Class 1E Vented Lead Acid Storage Batteries for Nuclear Power Generating Stations Qualification methods for Class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary... Active Standard
535-2006 - Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating Stations Qualification methods for class 1E vented lead acid batteries and racks to be used in nuclear power generating stations outside primary... Superseded Standard
650-1990 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations Methods for qualifying static battery chargers and inverters for Class 1E installations in a mild environment outside containment in nuclear power... Superseded Standard
650-1979 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations This standard describes methods for qualifying static battery chargers and inverters for Class 1E installations in environmentally controlled... Superseded Standard
650-2006 - Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations Methods for qualifying static battery chargers and inverters for Class 1E installations outside containment in nuclear power generating stations... Active Standard
937-2000 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems Design considerations and procedures for storage, location, mounting, ventilation, assembly and maintenance, of lead-acid storage batteries for... Superseded Standard
937-1987 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems This recommended practice provides design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of... Superseded Standard
937-2007 - Recommended Practice for Installation and Maintenance of Lead-Acid Batteries for Photovoltaic (PV) Systems Design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of lead-acid secondary batteries for... Active Standard
1013-2000 - Recommended Practice for Sizing Lead-Acid Batteries for Photovoltaic (PV) Systems A method for sizing both vented and valve-regulated lead-acid batteries used in terrestrial photovoltaic (PV) systems is described. Installation,... Superseded Standard
1013-1990 - Recommended Practice for Sizing Lead-Acid Batteries for Photovoltaic (PV) Systems Describes methods for sizing both vented and valve regulated lead-acid batteries used with terrestrial photovoltaic (PV) systems. The purpose is... Superseded Standard
1013-2007 - Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems A method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial... Active Standard
1106-1995 - Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications Installation design, installation, maintenance and testing procedures, and test schedules that can be used to optimize the life and performance of... Superseded Standard
1106-1987 - Recommended Practice for Maintenance, Testing, and Replacement of Nickel-Cadmium Storage Batteries for Generating Stations and Substations This recommended practice provides maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of... Superseded Standard
1106-2005 - Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications This recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be... Active Standard
1115-2000 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications The sizing of nickel-cadmium batteries used in full float operation for stationary applications is covered in this recommended practice. Superseded Standard
1115-1992 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications Methods for defining the dc load and for sizing a nickel-cadmium battery to supply that load are described. Installation, maintenance,... Superseded Standard
1115-2014 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications The sizing of nickel-cadmium batteries used in standby operation for stationary applications is discussed in this recommended practice. Active Standard
1115a-2007 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications Amendment 1: Additional Discussion on Sizing Margins This amendment provides additional guidance on sizing margins that may be applied when nickel-cadmium batteries are used in stationary... Superseded Standard
1144-1996 - Recommended Practice for Sizing Nickel-Cadmium Batteries for Photovoltaic (PV) Systems A method for sizing nickel-cadmium battery storage subsystems used in residential, commercial, and industrial photovoltaic (PV) systems is described. Withdrawn Standard
1145-1999 - Recommended Practice for the Installation and Maintenance of Nickel-Cadmium Batteries for Photovoltaic (PV) Systems Safety precautions, installation design considerations, and procedures for receiving, storing, commissioning, and maintaining pocketand fiber... Withdrawn Standard
1145-1990 - Recommended Practice for Installation and Maintenance of Nickel-Cadmium Batteries for Photovoltaic (PV) Systems The IEEE Recommended Practice for Installation and Maintenance of Nickel-Cadmium Batteries for Photovoltaic (PV) Systems, provides safety... Superseded Standard
1184-1994 - Guide for the Selection and Sizing of Batteries for Uninterruptible Power Systems The characteristics of the various battery energy systems available are described so that users can select the system best suited to their... Superseded Standard
1184-2006 - Guide for Batteries for Uninterruptible Power Supply Systems Various battery systems are discussed so that the user can make informed decisions on selection, installation design, installation, maintenance,... Active Standard
1187-1996 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Storage Batteries for Stationary Applications This IEEE standard covers recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly,... Superseded Standard
1187-2013 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary Applications This recommended practice provides guidance for the installation and installation design of valve-regulated lead acid (VRLA) batteries. This... Active Standard
1187-2002 - Recommended Practice for Installation Design and Installation of Valve-Regulated Lead-Acid Batteries for Stationary Applications This recommended practice provides guidance for the installation and installation design of valve-regulated lead acid (VRLA) batteries. This... Superseded Standard
1188-1996 - Recommended Practice for Maintenance, Testing, and Replacement of Valve- Regulated Lead-Acid (VRLA) Batteries for Stationary Applications In this IEEE standard maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of valve-regulated... Superseded Standard
Displaying results 1 - 40 of 64 - all