Inactive-Reserved Standard

IEEE 1493-2006

IEEE Guide for the Evaluation of Solvents Used for Cleaning Electrical Cables and Accessories

This guide provides test procedures for evaluating the physical characteristics of cable cleaning solvents and their compatibility with extruded dielectric cable components and cable accessories (joints and terminations). Compatibility is established by placing component samples in contact with the cleaning solvent for a short period and then measuring the physical or electrical properties of the component. The measured values are compared with values for samples that have not been in contact with the cleaner. Suggested performance values are provided. The guide also provides suggested procedures for evaluating the cleaning effectiveness of cable cleaning solvents. These comparative test procedures do not provide absolute performance values.

Sponsor Committee
PE/IC - Insulated Conductors
Learn More About PE/IC - Insulated Conductors
Status
Inactive-Reserved Standard
PAR Approval
2006-11-02
Board Approval
2006-12-06
History
ANSI Approved:
2007-04-23
Published:
2007-06-06
Inactivated Date:
2021-03-25

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/IC - Insulated Conductors
Learn More About PE/IC - Insulated Conductors
Working Group
B09W/P1493_WG - Guide for the Evaluation of Solvents Used for Cleaning Electrical Cables and Accessories
IEEE Program Manager
Dalisa Gonzalez
Contact Dalisa Gonzalez
Working Group Chair
Tom Fredericks

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P1493

IEEE Draft Guide for the Evaluation of Solvents Used for Cleaning Electrical Cables and Accessories

Test procedures for evaluating the physical characteristics of cable cleaning solvents and their compatibility with extruded dielectric cable components and cable accessories (joints and terminations) are provided in this guide. Compatibility is established by placing component samples in contact with the cleaning solvent for a short period and then measuring the physical or electrical properties of the component. The measured values are compared with values for samples that have not been in contact with the cleaner. Suggested performance values are provided. This guide also provides suggested procedures for evaluating the cleaning effectiveness of cable cleaning solvents. These comparative test procedures do not provide absolute performance values

Learn More About P1493

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.