IEEE-SA Standards Board Approvals

New and revised standards projects, as well as new and revised standards put forth for approval by the Standards Board.

IEEE-SA STANDARDS BOARD APPROVALS
17 JUNE 2009

Approved PARs for New Standards

  • P1805 (C/S2ESC): Guide for Requirements Capture Language (RCL)
  • P11073-20601a (EMB/11073): Health Informatics - Personal Health Device Communication - Application Profile - Optimized Exchange Protocol - Amendment:
  • P1595 (PE/ED&PG): Standard for Quantifying Greenhouse Gas Emission Credits from Small Hydro
    and Wind Power Projects, and for Grid Baseline Conditions
  • P62582-1 (PE/NPE): Nuclear Power Plants - Instrumentation and Control Important to Safety - Electrical Equipment Condition Monitoring Methods - Part 1: General
  • P62582-2 (PE/NPE): Nuclear Power Plants - Instrumentation and Control Important to Safety - Electrical Equipment Condition Monitoring Methods - Part 2: Indenter Modulus
  • P62582-3 (PE/NPE): Nuclear Power Plants - Instrumentation and Control Important to Safety - Electrical Equipment Condition Monitoring Methods - Part 3: Elongation at Break
  • P62582-4 (PE/NPE): Nuclear Power Plants - Instrumentation and Control Important to Safety - Electrical Equipment Condition Monitoring Methods Part 4: Oxidation Induction Techniques
  • P62582-5 (PE/NPE): Nuclear Power Plants - Instrumentation and Control Important to Safety - Â Electrical Equipment Condition Monitoring Methods Part 5: Optical Time Domain Reflectometry
  • PC37.06.1 (PE/SWG): Recommended Practice for Preferred Ratings for High-Voltage (>1000 Volts) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise Times
  • P1232.3 (SCC20): Guide for the Use of Artificial Intelligence Exchange and Service Tie to All Test Environments (AI-ESTATE)
  • P1653.5 (VT/RT): Recommended Practice for Controlled Rectifiers for Traction Power Substation Applications

PARs for Revision of Standards

  • P323 (PE/NPE): Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations and Nuclear Facilities
  • P497 (PE/NPE): Standard Criteria for Accident Monitoring Instrumentation for Nuclear Power Generating Stations
  • PC37.95 (PE/PSR): Guide for Protective Relaying of Utility-Consumer Interconnections
  • PC37.104 (PE/PSR): Guide for Automatic Reclosing of Line Circuit Breakers for AC Distribution and Transmission Lines
  • P535 (PE/SB): Standard for Qualification of Class 1E Vented Lead Storage Batteries for Nuclear Power Generating Stations

Modified PARs

  • P2600.2 (C/IA): Standard Protection Profile for Hardcopy Devices in IEEE Std. 2600™-2008 Operational Environment B
  • P2600.3 (C/IA): Standard Protection Profile for Hardcopy Devices in IEEE Std. 2600™-2008 Operational Environment C
  • P2600.4 (C/IA): Standard Protection Profile for Hardcopy Devices in IEEE Std. 2600™-2008 Operational Environment D
  • P1648 (C/S2ESC): Recommended Practice for the Customer-Supplier Relationship in Agile Software Development
  • P48 (PE/IC): Standard for Test Procedures and Requirements for Alternating Current Cable Terminations Used on Shielded Cables Having Laminated Insulation Rated 2.5 kV Through 765 kV or Extruded Insulation Rated 2.5 kV Through 500 kV
  • PC37.105 (PE/PSR): Standard for Qualifying Class 1E Protective Relays and Auxiliaries for Nuclear Power Generating Stations
  • PC37.122.2 (PE/SUB): Guide for the Application of Gas-Insulated Substations 1kV to 52kV
  • PC37.60 (PE/SWG): Standard for Automatic Circuit Reclosers and Fault Interrupters for Alternating Current Systems Up to 38 kV
  • PC37.74 (PE/SWG): Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems Up to 38 kV

Withdrawn PARs

  • P1505.2 (SCC20): Standard for the Common Test Interface Pin Map Configuration for Double-Tier Test Requirements Utilizing IEEE Std 1505

New Standards

  • P802.1Qaw (C/LM): IEEE Standard for Local and Metropolitan Area Networks - Virtual Bridged Local Area Networks - Amendment: Management of Data Driven and Data Dependent Connectivity Faults
  • P802.1Qay (C/LM): IEEE Standard for Local and Metropolitan Area Networks - Virtual Bridged Local Area Networks - Amendment: Provider Backbone Bridge Traffic Engineering
  • P1559 (AES/GA): Standard for Inertial Systems Terminology
  • P1628 (VT/RT): Recommended Practice for Maintenance for DC Overhead Contact Systems for Transit Systems
  • P1783 (DEI/SC): Guide for Test Methods and Procedures to Evaluate the Electrical Performance of Insulators in Freezing Conditions
  • PC37.04-1999/Cor 1 (PE/SWG): IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers - Corrigendum 1

Revision Standards

  • P48 (PE/IC): Standard for Test Procedures and Requirements for Alternating Current Cable Terminations Used on Shielded Cables Having Laminated Insulation Rated 2.5 kV Through 765 kV or Extruded Insulation Rated 2.5 kV Through 500 kV
  • P836 (AES/GA): Recommended Practice for Precision Centrifuge Testing of Linear Accelerometers
  • P1613 (PE/SUB): Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations
  • PC57.12.24 (PE/TR): Standard for Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 Volts and Below; Low Voltage, 600 Volts and Below

Reaffirmations

  • 521-2002 (AES/RS): IEEE Standard Letter Designations for Radar-Frequency Bands