IEEE-SA Standards Board: RevCom

Responsible for coordinating the development, publication and revision of IEEE standards.

REVIEW COMMITTEE (REVCOM) RECOMMENDATIONS

29 September 2010
[All votes are unanimous unless noted otherwise.]

NEW

P802.1Qat/D6.1 (C/LM) Standard for Local and Metropolitan Area Networks—Virtual Bridged Local Area Networks Amendment: Stream Reservation Protocol (SRP)
Recommendation: APPROVE

P802.3az/D3.2 (AES/GA) IEEE Standard for Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications - Amendment: Media Access Control Parameters, Physical Layers and Management Parameters for Energy-Efficient Ethernet
Recommendation: APPROVE
David Law recused himself from the vote on this item, as he is the working group chair.

P802.11z/D13.0 (C/LM) Standard for Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements - Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications - Amendment 7: Extensions to Direct Link Setup (DLS)
Recommendation: APPROVE
[yes = 6; no = 0; abstain = 1 (Thompson)]
Bruce Kraemer recused himself from the vote on this item, as he is the working group chair.

P802.22.1/D8 (C/LM) Standard to Enhance Harmful Interference Protection for Low Power Licensed Devices Operating in TV Broadcast Band
Recommendation: APPROVE
[yes = 7; no = 1 (Thompson); abstain = 0]

P1597.2/D7.2 (EMC/SDCom) Recommended Practice for Validation of Computational Electromagnetics Computer Modeling and Simulations
Recommendation: APPROVE
[yes = 6; no = 2; abstain = 0]

P1619.2/D16 (C/IA) Standard for Wide-Block Encryption for Shared Storage Media
Recommendation: APPROVE

P1636/(SASB/SCC20) Standard for Software Interface for Maintenance Information Collection and Analysis (SIMICA): Exchanging Maintenance Action Information via the Extensible Markup Language (XML)
Recommendation: APPROVE

P1651/D8 (PE/T&D) Guide for Testing the Electrical, Mechanical, and Durability Performance of Wildlife Protective Devices on Overhead Power Distribution Systems Rated up to 38 kV
Recommendation: APPROVE
[yes = 7; no = 1; abstain = 0 (Thompson)]

P1656/D10 (PE/T&D) Guide for Testing the Electrical, Mechanical, and Durability Performance of Wildlife Protective Devices on Overhead Power Distribution Systems Rated up to 38 kV
Recommendation: APPROVE

P1901/D4.01 (COM/SC) Standard for Broadband over Power Line Networks: Medium Access Control and Physical Layer Specifications
Recommendation: CONDITIONALLY APPROVED
[yes = 7; no = 1 (Thompson); abstain = 1 (Sciacca)]
There was a motion to conditionally approve P1901 conditional on SASB approval of the modified PAR.

P3007.2/D2 (IAS/TBCC) Recommended Practice for the Maintenance of Industrial and Commercial Power Systems
Recommendation: APPROVE

P11073-10421/D11 (EMB/11073) Health Informatics - Personal Health Device Communication - Device Specialization - Peak Expiratory Flow Monitor (Peak Flow)
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

P11073-20601a/D31 (EMB/11073) Health Informatics - Personal Health Device Communication - Part 20601: Application Profile - Optimized Exchange Protocol Amendment 1
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1

PC37.017/D6 (PE/SWG & PE/SUB) Standard for Bushings for High Voltage (Over 1000 Volts AC) Circuit Breakers and Gas Insulated Switchgear
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

PC37.239/D0.5 (PE/PSR) Standard for Common Format for Event Data Exchange (COMFEDE) for Power Systems
Recommendation: CONDTIONALLY APPROVED
[yes = 7; no = 0; abstain = 1]
There was a motion to conditionally approve PC37.239 conditional on the modified PAR being approved by SASB.

PC57.12.10/D5.3 (PE/TR) Standard Requirements for Liquid-Immersed Power Transformers
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

REVISION

P114//D1 (IAS/EM) Standard Test Procedure for Single-Phase Induction Motors
Recommendation: APPROVE

P356/D8 (APS/P) Guide for Measurements of Electromagnetic Properties of Earth Media
Recommendation: APPROVE

P497/D3 (PE/NPE) Standard Criteria for Accident Monitoring Instrumentation for Nuclear Power Generating Stations
Recommendation: APPROVE

P977/D3 (PE/T&D) Guide to Installation of Foundations for Transmission Line Structures
Recommendation: APPROVE

P1036/D16rev3 (PE/T&D) Guide for the Application of Shunt Power Capacitors
Recommendation: APPROVE

P1185/D12 (PE/IC) Recommended Practices for Cable Installation in Generating Stations and Industrial Facilities
Recommendation: APPROVE
There was a motion to conditionally approve this conditional on a satisfactory legal review.

P1410/D7 (PE/T&D) Guide for Improving the Lightning Performance of Electric Power Overhead Distribution Lines
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1 (Thompson)]

P1505/D8 (SASB/SCC20) Standard for Receiver Fixture Interface
Recommendation: APPROVE

P1580/D4 (IAS/PCI) Recommended Practice for Marine Cable for use on Shipboard and Fixed or Floating Facilities
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1 (Thompson)]

P1609.3/D9 (VT/ITS) Standard for Wireless Access in Vehicular Environments (WAVE) - Networking Services
Recommendation: APPROVE

P1609.4/D9 (VT/ITS) Standard for Wireless Access in Vehicular Environments (WAVE) - Multi-Channel Operation
Recommendation: APPROVE

P1671/D14 (SASB/SCC20) Standard for Automatic Test Markup Language (ATML) for Exchanging Automatic Test Equipment and Test Information via XML
Recommendation: APPROVE

P1730/D5 (C/SI) Recommended Practice for Distributed Simulation Engineering and Execution Process
Recommendation: APPROVE

PC37.105/>D12 (PE/PSR) Standard for Qualifying Class 1E Protective Relays and Auxiliaries for Nuclear Power Generating Stations
Recommendation: APPROVE
[yes = 5; no = 3 (Diab, Siller, Thompson); abstain = 1 (Logvinov)]

PC37.122/D19 (PE/SUB) Standard for High Voltage Gas-Insulated Substations Rated Above 52 kV
Recommendation: APPROVE
[yes = 8; no = 0; abstain = 1]

PC57.12.80/D6 (PE/TR) Standard Terminology for Power and Distribution Transformers
Recommendation: APPROVE

REAFFIRMATION

67-2005 (PE/EM) IEEE Guide for Operation and Maintenance of Turbine Generators
Recommendation: APPROVE
[yes = 6; no = 0; abstain = 2]

517-1974 (R2005) (AES/GA) IEEE Standard Specification Format Guide and Test Procedure for Single-Degree-of-Freedom Rate-Integrating Gyros
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

529-1980 (R2005) (AES/GA) Supplement for Strapdown Applications to IEEE Standard Specification Format Guide and Test Procedure for Single-Degree-of-Freedom Rate-Integrating Gyros
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

539-2005 (PE/T&D) IEEE Standard Definitions of Terms Relating to Corona and Field Effects of Overhead Power Lines
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

643-2004 (PE/PSC) IEEE Guide for Power-Line Carrier Applications
Recommendation: APPROVE
[yes = 6; no = 0; abstain = 2]

802.15.1-2005 (C/LM) IEEE Standard for Information Technology - Telecommunications and information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements Part 15.1: Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Wireless Personal Area Networks (WPANs)
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

1082-1997 (R2003) (PE/NPE) IEEE Guide for Incorporating Human Action Reliability Analysis for Nuclear Power Generating Stations
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

1308-1994 (R2001) (PE/T&D) IEEE Recommended Practice for Instrumentation: Specifications for Magnetic Flux Density and Electric Field Strength Meters - 10 Hz to 3 kHz
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

1484.11.1-2004 (C/LT) IEEE Standard for Learning Technology - Data Model for Content Object Communication
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

1623-2004 (PE/SUB) IEEE Guide for the Functional Specification of Medium Voltage (1 kVˇ35 kV) Electronic Shunt Devices for Dynamic Voltage Compensation
Recommendation: APPROVE
[yes = 6; no = 0; abstain = 2 (Sciacca recorded)]

11073-30200-2000 (EMB/11073) Health Informatics - Point-of-Care Medical Device Communication - Part 30200: Transport Profile - Cable Connected
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

C37.93-2004 (PE/PSR) IEEE Guide for Power System Protective Relay Applications of Audio Tones Over Voice Grade Channels
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

C50.12-2005 (PE/EM) IEEE Standard for Salient-Pole 50 Hz and 60 Hz Synchronous Generators and Generator/Motors for Hydraulic Turbine Applications Rated 5 MVA and Above
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1]

C50.13-2005 (PE/EM) IEEE Standard for Cylindrical-Rotor 50 Hz and 60 Hz Synchronous Generators Rated 10 MVA and Abov
Recommendation: APPROVE
[yes = 7; no = 0; abstain = 1